Quantum Efficiency Study and Reflectivity Enhancement of Au/Bi Absorbers
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to M. E. Eckart.
Explore the source record for details and available documents.
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter array to perform high-resolution X-ray spectroscopy. This instrument flew for the first time on July 22nd, 2018, from the White Sands Missile Range, USA. This flight marks the first successful operation of a transition-edge sensor array and its time-division multiplexing readout system in space. This launch was dedicated to the observation of the supernova remnant Cassiopeia A. A failure in the attitude control system prevented the rocket from pointing and led to no time on target. The onboard calibration source provided X-rays in flight, and it is used to compare detector performance during preflight integration, flight, and after the successful post-flight recovery. This calibration data demonstrate the capabilities of the detector in a space environment as well as its potential for future flight.
Microcalorimeters have the potential to provide line shapes well-described by a single Gaussian broadening term of few-eV width. This attribute makes the detectors especially well suited for x-ray astrophysics observations; however, low-level non-Gaussian broadening terms are expected and must be characterized. These terms depend on the composition of the x-ray absorber, the detailed x-ray absorption physics, the device thermalization processes, and the incident x-ray energy. Here we present the first measurements targeted at understanding the extended line-spread function (LSF) of x-ray microcalorimeter pixels under development for the X-ray Integral Field Unit (XIFU) on the Athena X-ray Observatory. These pixels are comprised of Mo/Au transition-edge sensors (TESs) with overhanging electroplated Au/Bi absorbers. We measured the line shapes using monochromatic x-ray sources with < 1 eV width at several x-ray energies (0.85, 0.93, 1.25, 1.5, 5.4, and 8.0 keV) across the instrument bandpass (0.3-12 keV) and modeled the line profiles. These results are compared to the extended LSF of the Hitomi microcalorimeter pixels that used HgTe absorbers.