Search NASA⌕ Search

Engineering topics

MacKenty, John W.

Publications and source records attributed to MacKenty, John W..

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗

Effects of Forged Stock and Pure Aluminum Coating on Cryogenic Performance of Heat Treated Aluminum Mirrors

We present the results of an on-going test program designed to empirically determine the effects of different stress relief procedures for aluminum mirrors. Earlier test results identified a preferred heat treatment for flat and spherical mirrors diamond turned from blanks cut out of Al 6061-T651 plate stock. Further tests have been performed on mirrors from forged stock and one set from plate stock coated with Alumiplate(trademark) aluminum coating to measure the effect of these variables on cryogenic performance. The mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for three thermal cycles. We correlate the results of our optical testing with heat treatment and metallographic data.

Toland, Ronald W.↗

Effects of Forged Stock and Pure Aluminum Coating on Cryogenic Performance of Heat Treated Aluminum Mirrors

In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress that may relieve and distort mirror figure to unacceptable levels at cryogenic operating temperatures unless relieved during fabrication. Cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of an on-going test program designed to empirically determine the effects of different stress relief procedures for aluminum mirrors. Earlier test results identified a preferred heat treatment for flat and spherical mirrors diamond turned from blanks cut out of Al6061-T651 plate stock. Further tests have been performed on mirrors from forged stock and one set from plate stock coated with Alumiplate(TM) aluminum coating to measure the effect of these variables on cryogenic performance. The mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for three thermal cycles. We correlate the results of our optical testing with heat treatment and metallographic data.

Toland, Ronald↗

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗