Search NASA⌕ Search

Engineering topics

Mackenzie, M.

Publications and source records attributed to Mackenzie, M..

Workshop on a future muon program at FNAL

The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.

43 PARTICLE ACCELERATORS↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of metal artifacts in MVCT systems using a model based correction method

Purpose: To evaluate the performance of a model based image reconstruction method in reducing metal artifacts in the megavoltage computed tomography (MVCT) images of a phantom representing bilateral hip prostheses and to compare with the filtered-backprojection (FBP) technique. Methods: An iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with an additional model for the pair/triplet production process and the energy dependent response of the detectors. The beam spectra for an in-house bench-top and TomoTherapy Trade-Mark-Sign MVCTs are modeled for use in IMPACT. The empirical energy dependent response of detectors is calculated using a constrained optimization technique that predicts the measured attenuation of the beam by various thicknesses (0-24 cm) of solid water slabs. A cylindrical (19.1 cm diameter) plexiglass phantom containing various cylindrical inserts of relative electron densities 0.295-1.695 positioned between two steel rods (2.7 cm diameter) is scanned in the bench-top MVCT that utilizes the bremsstrahlung radiation from a 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C and in the imaging beam of the TomoTherapy Trade-Mark-Sign MVCT. The FBP technique in bench-top MVCT reconstructs images from raw signal normalized to air scan and corrected for beam hardening using a uniform plexiglass cylinder (20 cm diameter). The IMPACT starts with a FBP reconstructed seed image and reconstructs the final image in 150 iterations. Results: In both MVCTs, FBP produces visible dark shading in the image connecting the steel rods. In the IMPACT reconstructed images this shading is nearly removed and the uniform background is restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding values in the absence of the steel inserts. In the FBP images of the bench-top MVCT, the shading causes 4%-9.5% underestimation of electron density at the central inserts with an average of (6.3 {+-} 1.8)% for the range of electron densities studied. In the uniform plexiglass background, the shadow creates 0.8%-4.7% underestimation of electron density with an average of (2.9 {+-} 1.2)%. In the corresponding IMPACT images, the underestimation in the shaded plexiglass background is 0.3%-1.8% with an average of (0.9 {+-} 0.5)% and 1.4%-6.8% with an average of (2.8 {+-} 2.7)% in the central insert region. In the FBP images of the TomoTherapy Trade-Mark-Sign MVCT, this shading creates 2.6%-6.7% underestimation of electron density with an average of (3.7 {+-} 1.4)% at the central inserts and 5.9%-7.2% underestimation in the background with an average of (6.4 {+-} 0.5)%. In the IMPACT images, the uniform background between the steel rods is restored with 0.3%-1.0% underestimation of electron density with an average of (0.7 {+-} 0.3)%. The corresponding underestimation at the central inserts of the IMPACT images is -0.4%-0.1% with an average of (-0.1 {+-} 0.2)%. Conclusions: The shading metal artifact has been nearly removed in MVCT images using the IMPACT algorithm with the accurate geometry of the system, proper modeling of energy dependent response of detectors, and all relevant photon interaction processes. This results less than 1% difference in electron density in the background plexiglass and less than 3% averaged over the range of electron densities investigated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗