Search NASA⌕ Search

Engineering topics

Mackinnon, A.

Publications and source records attributed to Mackinnon, A..

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Diagnosing inertial confinement fusion ignition

Abstract Fusion ignition by inertial confinement requires compression and heating of the fusion fuel to temperatures in excess of 5 keV and densities exceeding hundreds of g/cc. In August 2021, this scientific milestone was surpassed at the National Ignition Facility (NIF), when the Lawson criterion for ignition was exceeded generating 1.37MJ of fusion energy (Abu-Shawareb et al 2022 Phys. Rev. Lett. 129 075001), and then in December 2022 target gain >1 was realized with the production of 3.1MJ of fusion energy from a target driven by 2.0MJ of laser energy (Abu-Shawareb et al 2024 Phys. Rev. Lett. 132 065102). At the NIF, inertial confinement fusion research primarily uses a laser indirect drive in which the fusion capsule is surrounded by a high-Z enclosure (‘hohlraum’) used to convert the directed laser energy into a symmetric x-ray drive on the capsule. Precise measurements of the plasma conditions, x-rays, γ -rays and neutrons produced are key to understanding the pathway to higher performance. This paper discusses the diagnostics and measurement techniques developed to understand these experiments, focusing on three main topics: (1) key diagnostic developments for achieving igniting plasmas, (2) novel signatures related to thermonuclear burn and (3) advances to diagnostic capabilities in the igniting regime with a perspective toward developments for intertial fusion energy.

Moore, A. S. (ORCID:0000000221258882)↗

Extended X-ray absorption fine structure of dynamically-compressed copper up to 1 terapascal

Abstract Large laser facilities have recently enabled material characterization at the pressures of Earth and Super-Earth cores. However, the temperature of the compressed materials has been largely unknown, or solely relied on models and simulations, due to lack of diagnostics under these challenging conditions. Here, we report on temperature, density, pressure, and local structure of copper determined from extended x-ray absorption fine structure and velocimetry up to 1 Terapascal. These results nearly double the highest pressure at which extended x-ray absorption fine structure has been reported in any material. In this work, the copper temperature is unexpectedly found to be much higher than predicted when adjacent to diamond layer(s), demonstrating the important influence of the sample environment on the thermal state of materials; this effect may introduce additional temperature uncertainties in some previous experiments using diamond and provides new guidance for future experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancement of high energy X-ray radiography using compound parabolic concentrator targets

We report an increase in MeV energy bremsstrahlung x-ray production using compound parabolic concentrators (CPC) compared to flat solid targets during relativistic laser-plasma experiments on a 140 J, 150 fs laser system using an f/40 focusing optic. CPC enhanced targets show a > 3x increase in high energy x-ray production over planar foil targets. Furthermore, this enhancement in x-ray energy spectra shows a direct improvement in the radiography of an image quality indicator (IQI) object with a 20 g/cm 2 areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (∼0.8 ps–20 ps). Maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancements in laser-generated hot-electron production via focusing cone targets at short pulse and high contrast

We report on the increase in the accelerated electron number and energy using compound parabolic concentrator (CPC) targets from a short-pulse (~150 fs), high-intensity (>10 18 W/cm 2 ), and high-contrast (~10 8 ) laser-solid interaction. We report on experimental measurements using CPC targets where the hot-electron temperature is enhanced up to ~ 9 times when compared to planar targets. The temperature measured from the CPC target is (T e ) = 4.4 ± 1.3 MeV. Using hydrodynamic and particle in cell simulations, we identify the primary source of this temperature enhancement is the intensity increase caused by the CPC geometry that focuses the laser, reducing the focal spot and therefore increasing the intensity of the laser-solid interaction, which is also consistent with analytic expectations for the geometrical focusing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scaling of laser-driven electron and proton acceleration as a function of laser pulse duration, energy, and intensity in the multi-picosecond regime

A scaling study of short-pulse laser-driven proton and electron acceleration was conducted as a function of pulse duration, laser energy, and laser intensity in the multi-picosecond (ps) regime (~0.8 ps–20 ps). Furthermore, maximum proton energies significantly greater than established scaling laws were observed, consistent with observations at other multi-ps laser facilities. In addition, maximum proton energies and electron temperatures in this regime were found to be strongly dependent on the laser pulse duration and preplasma conditions. A modified proton scaling model is presented that is able to better represent the accelerated proton characteristics in this multi-ps regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗