A paradigm shift for evaluating natural attenuation of radioactive iodine in soils and sediments: Species-specific mechanisms and pathways
Not Available
Engineering topics
Publications and source records attributed to Mackley, Rob D..
Not Available
The issues associated with long-screened wells (LSWs) (and open boreholes) at contaminated sites are well documented in the groundwater literature but are still not fully appreciated in practice. As established in seminal and review papers going back over three decades, the interpretation of sampling results from LSWs is challenging in the presence of vertical hydraulic gradients and borehole flow; furthermore, LSWs allow for vertical redistribution of contamination between aquifer layers. Acknowledgment of these issues has led to the development of new technologies and well designs to enable discrete-zone monitoring (DZM), yet LSWs remain common for many reasons, for example, as multipurpose wells, for geophysical logging, and (or) as legacy installations. Despite the literature on LSWs and despite the adoption of DZM at many sites, the use of LSWs persists and the challenges of interpreting sampling results from LSWs remain. In this issue paper, we provide a conceptual overview of the problems posed by LSWs and review existing literature and past work to improve the interpretation of sampling in LSWs. We draw on experience from previous studies at the Hanford Site in eastern WA, USA, and use synthetic examples to illustrate key concepts and challenges for interpretation. A recently published analytical modeling framework is used to develop illustrative synthetic examples and demonstrate a workflow for building scientific intuition to understand issues around interpreting samples from LSWs, which is critical to effective characterization and groundwater remediation at sites with LSWs.
Not Available
At contaminated sites, there is a critical reliance on conceptual site models of which a key component is the geologic framework model (GFM), which is used to build predictive fate and transport modeling in support of remediation goals. Here, we detail an ongoing study at a nuclear waste site (Hanford Site, Washington, USA) where surface geophysical methods were used to complement existing borehole information and to help site new boreholes to update and refine the GFM. Ground-based electrical resistivity tomography (ERT), time-domain electromagnetics (TEM), and seismic data was acquired on the Hanford Site’s Central Plateau, where the presence of a hydraulically transmissive subsurface feature, or paleochannel, was suspected but uncertain based on contaminant concentrations at sparsely located boreholes. To assess and compare ERT, TEM, and seismic geophysical datasets, co-located data was acquired in an area where the existing GFM was more certain. Surrounding the suspected paleochannel, ERT and seismic refraction tomography showed similar subsurface structures consistent with a channelized feature. While TEM interpretation was limited in the suspected paleochannel area due to a thick resistive top layer and high electromagnetic noise, TEM showed greater utility in a different area where these factors were less prevalent. Based on the results of quasi-3D ERT inversions, we propose updates to the GFM, including identifying a paleochannel. Further, we evaluate the utility of geophysical methods and examine lessons learned that will be used as a basis for continued characterization efforts to support site management decisions and implementation efforts.
The selectivity of ion exchange (IX) resins for aqueous contaminant removal can be impacted by changing concentrations of competing natural groundwater ions. In a two-part investigation, the Hanford Site 200 West Area pump-and-treat (P&T) facility in Washington State, USA is used as a case study to evaluate the performance of two IX resins for groundwater treatment: Purolite® A532E for pertechnetate (TcO 4 - ) removal, explored in Part I, and DOWEX 21K (DOWEX) for uranium (U) removal. In Part II, DOWEX selectivity for U, as uranyl carbonate species, and uptake kinetics is quantified in a series of laboratory-scale aqueous batch experiments containing Hanford-relevant concentrations of competing anions nitrate (NO 3 - ), sulfate (SO 4 2- ), chloride (Cl - ), and carbonate (CO 3 2- ), as well as co-mingled contaminant TcO 4 - . Here the results demonstrate that DOWEX trimethylammonium functional groups are highly selective for U carbonate species (85–100 % uptake) under all conditions investigated. Only NO 3 - concentrations of 100 mM were shown to decrease U removal, with the extent (85–99 %) depending on competing anion concentrations present in solution. However, at the highest NO 3 - concentrations reported for groundwaters treated at the P&T facility (25 mM), the effect on U uptake is minimal. The batch sorption results are modeled to obtain chloride normalized equilibrium exchange coefficients (K) for predicting DOWEX performance: K SO4--/Cl- = 2.0, K NO3-/Cl- = 5.0, K HCO3-/Cl- = 1.5, K TcO4-/Cl- = 2,000, and K U/Cl- = 50,000. These K values predict little effect of current and future influent chemistries on U removal by DOWEX, where both uranyl carbonate species and TcO 4 - are removed such that effluent concentrations meet groundwater treatment requirements.
Cr(VI) flushing from the vadose zone to the groundwater (with subsequent Cr(VI) removal in groundwater by pump-and-treat system) is a promising remedial technique that has recently been used at field scale. This laboratory study was conducted to provide the technical basis to design a field soil flushing strategy. The objectives were to (1) quantify the relationship between sediment Cr(VI) and Cr(III) mass and release rates and subsequent Cr(VI) leaching; (2) investigate different methodologies to maximize Cr(VI) leaching, and (3) investigate methods to minimize leaching of remaining residual Cr. Characterization of Cr-contaminated sediments (Hanford Site, WA) exhibited Cr(VI) showed that leach rates that were correlated to different Cr surface phases. Sediments with low leachable Cr(VI) (<2 μg/g) leached Cr rapidly, so slow infiltration of water in a single pulse was sufficient to leach most Cr. In contrast, sediments with high Cr (2 to 200 μg/g) released some Cr(VI) quickly but 10 to 50% Cr(VI) slowly (tens to hundreds of hours). Efficient unsaturated leaching of these sediments required a different infiltration strategy that includes: multiple slow leach pulses with time between flushing cycles; the use of a surfactant to increase Cr leaching from low-permeability zones, and the use of a reductant (Na-dithionite or Ca-polysulfide) in the final leach water was highly effective at decreasing residual Cr leaching. This study clearly demonstrated that the methodology of basing laboratory Cr flushing on parameters such as Cr release mass and rates could be used to improve the efficiency of soil flushing at field scale.
Performing repeat pore-fluid sampling over long time-scales can provide valuable information on unsaturated zone contaminants and their potential flux to ground water. This information can be used to manage groundwater remedies and identify contaminants that need to be sequestered in the vadose zone to minimize flux to ground water. Pore-water samples are commonly used to obtain contaminant concentrations within the vadose zone, but existing methods are limited as they only provide a single sample at one location and time. The vadose zone advanced monitoring system (VZAMS) has been designed to integrate multiple technologies into a single down-borehole system that allows for sampling of pore fluids (liquid and gas) to provide information about contamination and hydraulic conditions at multiple depths (~0.3-m intervals) within a cased borehole. Testing has been completed at the laboratory scale to verify the sampling elements of VZAMS, including geochemical testing for representative contaminants known to exist at the Hanford Site, located in southeastern Washington State. Physical tests focused on the ability of the sampler to draw fluid under unsaturated conditions. Initial geochemical testing showed that the stainless steel material used with the porous cuff may affect the sampled concentrations of redox-sensitive contaminants under very dry conditions. Additional laboratory testing demonstrated that the VZAMS components are able to collect representative samples for substances of interest under expected field conditions. In this paper, the design and functionality of a novel instrument are demonstrated in support of subsequent testing in the field.
A Noble Gas Migration Experiment (NGME) funded by the National Center for Nuclear Security and conducted at the Nevada National Security Site (NNSS) in collaboration with Lawrence Livermore national Laboratory and National Security Technology provided critical on-site inspection (OSI) information related to the detection of an underground nuclear explosion (UNE) event using noble gas signatures.
The overall goal of environmental remediation is to protect human health and the environment. Implementing renewable energy sources such as solar photovoltaic (PV) in groundwater extraction and pump-and-treat (P&T) systems may help minimize the environmental footprint of remediation efforts. The first step in considering solar PV for powering Hanford groundwater extraction is assessing the technical and economic feasibility and identifying potential target locations where implementation would be most successful. Accordingly, a techno-economic assessment of solar PV for Hanford groundwater extraction was completed in FY15. Multiple solar PV alternatives ranging in size from 1.2 to 22.4 kWp DC were evaluated and compared against traditional grid-powered systems. Results indicate that the degree to which solar PV alternatives are feasible is primarily a function of the distance of avoided power cable costs and the inclusion of an energy storage component. Standalone solar PV systems provide an energy source at the well and avoid the costs and logistics associated with running long lengths of expensive power cable to the well-head. When solar PV systems include a battery storage component, groundwater can be pumped continuously day and night in a year-round schedule. However, due to the high cost premium of the energy storage component, a fully solar-powered solution could not provide an economic direct replacement for line-powered pumping systems. As a result, the most ideal target locations for successful implementation of solar PV on the Hanford Site are remote or distant extraction wells where the primary remedial objective is contaminant mass removal (as opposed to hydraulic containment) and three-season (March through October) intermittent pumping is acceptable (e.g. remediation of hexavalent chromium in 200-UP-1).
Heterogeneity of hydraulic properties in aquifers may lead to contaminants residing in lower-permeability zones where it is difficult to deliver remediation amendments using conventional injection processes. The focus of this effort is to examine use of a shear-thinning fluid (STF) to improve the uniformity of remedial amendment distribution within a heterogeneous aquifer. Previous studies have demonstrated the significant potential of STFs for improving remedial amendment delivery in heterogeneous aquifers, but quantitative evaluation of these improvements from field applications are lacking. A field-scale test was conducted that compares data from successive injection of a tracer in water followed by injection of a tracer in a STF to evaluate the impact of the STF on tracer distribution uniformity in the presence of permeability contrasts within the targeted injection zone. Data from tracer breakthrough at multiple depth-discrete monitoring intervals and electrical resistivity tomography showed that inclusion of STF in the injection solution slowed movement in high-permeability pathways, improved delivery of amendment to low-permeability materials, and resulted in better uniformity in injected fluid distribution within the targeted treatment zone.
Slug tests performed using mini-piezometers with diameters as small as 0.43 cm can provide a cost effective tool for hydraulic characterization. We evaluated the hydraulic properties of the apparatus in an infinite hydraulic conductivity environment and compared those results with field tests of mini-piezometers installed into locations with varying hydraulic properties. Based on our evaluation, slug tests conducted in mini-piezometers using the fabrication and installation approach described here are effective within formations where the hydraulic conductivity is less than 1 x 10-3 cm/s. While these constraints limit the potential application of this method, the benefits to this approach are that the installation, measurement and analysis is extremely cost effective, and the installation can be completed in areas where other (larger diameter) methods might not be possible. Additionally, this methodology could be applied to existing mini-piezometers previously installed for other purposes. Such analysis of existing installations could be beneficial in interpreting previously collected data (e.g. water quality data or hydraulic head data).
Heterogeneity of hydraulic properties in aquifers may lead to contaminants residing in lower-permeability zones where it is difficult to deliver remediation amendments using conventional injection processes. The focus of this effort is to examine use of a shear-thinning fluid (STF) to improve the uniformity of remedial amendment distribution within a heterogeneous aquifer. Previous studies have demonstrated the significant potential of STFs for improving remedial amendment delivery in heterogeneous aquifers, but quantitative evaluation of these improvements from field applications are lacking. A field-scale test was conducted that compares data from successive injection of a tracer in water followed by injection of a tracer in a STF to evaluate the impact of the STF on tracer distribution uniformity in the presence of permeability contrasts within the targeted injection zone. Data from tracer breakthrough at multiple depth-discrete monitoring intervals and electrical resistivity tomography showed that inclusion of STF in the injection solution slowed movement in high-permeability pathways, improved delivery of amendment to low-permeability materials, and resulted in better uniformity in injected fluid distribution within the targeted treatment zone.
The FutureGen 2.0 Project will design and build a first-of-its-kind, near-zero emissions coal-fueled power plant with carbon capture and storage (CCS). To assess storage site performance and meet the regulatory requirements of the Class VI Underground Injection Control (UIC) Program for CO2 Geologic Sequestration, the FutureGen 2.0 project will implement a suite of monitoring technologies designed to 1) evaluate CO2 mass balance and 2) detect any unforeseen loss in CO2 containment. The monitoring program will include direct monitoring of the injection stream and reservoir, and early-leak-detection monitoring directly above the primary confining zone. It will also implement an adaptive monitoring strategy whereby monitoring results are continually evaluated and the monitoring network is modified as required, including the option to drill additional wells in out-years. Wells will be monitored for changes in CO2 concentration and formation pressure, and other geochemical/isotopic signatures that provide indication of CO2 or brine leakage. Indirect geophysical monitoring technologies that were selected for implementation include passive seismic, integrated surface deformation, time-lapse gravity, and pulsed neutron capture logging. Near-surface monitoring approaches that have been initiated include surficial aquifer and surface- water monitoring, soil-gas monitoring, atmospheric monitoring, and hyperspectral data acquisition for assessment of vegetation conditions. Initially, only the collection of baseline data sets is planned; the need for additional near- surface monitoring will be continually evaluated throughout the design and operational phases of the project, and selected approaches may be reinstituted if conditions warrant. Given the current conceptual understanding of the subsurface environment, early and appreciable impacts to near-surface environments are not expected.
In an open-loop groundwater heat pump (GHP) system, groundwater is extracted, run through a heat exchanger, and injected back into the ground, resulting in no mass balance changes to the flow system. Although the groundwater use is non-consumptive, the withdrawal and injection of groundwater may cause negative hydraulic and thermal impacts to the flow system. Because GHP is a relatively new technology and regulatory guidelines for determining environmental impacts for GHPs may not exist, consumptive use metrics may need to be used for permit applications. For consumptive use permits, a radius of influence is often used, which is defined as the radius beyond which hydraulic impacts to the system are considered negligible. In this paper, the hydraulic radius of influence concept was examined using analytical and numerical methods for a non-consumptive GHP system in southeastern Washington State. At this location, the primary hydraulic concerns were impacts to nearby contaminant plumes and a water supply well field. The results of this study showed that the analytical techniques with idealized radial flow were generally unsuited because they over predicted the influence of the well system. The numerical techniques yielded more reasonable results because they could account for aquifer heterogeneities and flow boundaries. In particular, the use of a capture zone analysis was identified as the best method for determining potential changes in current contaminant plume trajectories. The capture zone analysis is a more quantitative and reliable tool for determining the radius of influence with a greater accuracy and better insight for a non-consumptive GHP assessment.
Remediation activities over time will alter the subsurface distribution of contaminants and likely create significant changes in the source-zone architecture. A field method was demonstrated for use of data collected from multiple individual soil vapor extraction (SVE) system well tests to locate and characterize the distribution of persistent VOC sources in the vadose zone. Operational data collected at the Department of Energy’s Hanford site were used to examine source zone alteration over time due to SVE operation and to illustrate the source-zone characterization approach. Individual well test results confirmed a heterogeneous distribution of permeability and contaminant mass discharge throughout the vadose zone. The trends in mass discharge and concentration were analyzed to determine the location and extent of the primary source zone within a lower-permeability unit at the site. This information is useful to evaluate the performance of SVE operations, and support decisions concerning system alteration or closure based on risk assessments of the impact of vadose-zone sources on groundwater contamination or vapor intrusion.
Deep excavation of soil has been conducted at the 100-C-7 and 100-C-7:1 waste sites within the 100-BC Operable Unit at the Department of Energy (DOE) Hanford Site to remove hexavalent chromium (Cr(VI)) contamination with the excavations reaching to near the water table. Soil sampling showed that Cr(VI) contamination was still present at the bottom of the 100-C-7:1 excavation. In addition, Cr(VI) concentrations in a downgradient monitoring well have shown a transient spike of increased Cr(VI) concentration following initiation of excavation. Potentially, the increased Cr(VI) concentrations in the downgradient monitoring well are due to Cr(VI) from the excavation site. However, data were needed to evaluate this possibility and to quantify the overall impact of the 100-C-7:1 excavation site on groundwater. Data collected from a network of aquifer tubes installed across the floor of the 100-C-7:1 excavation and from temporary wells installed at the bottom of the entrance ramp to the excavation were used to evaluate Cr(VI) releases into the aquifer and to estimate local-scale hydraulic properties and groundwater flow velocity.
A treatability test was conducted in 2011 at the 216-Z-9 Trench to evaluate methods for collecting characterization information that supports refined assessment of SVE performance goals based on impact to groundwater. The characterization information can also provide input to operational strategies for continued SVE operation and decisions regarding closure of the SVE system or transition to other remedies, if necessary.