Integrating critical water issues into long-term planning for WECC.
Abstract not provided.
Engineering topics
Publications and source records attributed to Macknick, Jordan.
Abstract not provided.
Not Available
This report analyzes the installed system cost of various multi-land use PV system configurations. We used PV system bottom-up cost model accounting for all system and project-development costs incurred during the installation to model the costs for conventional PV systems, PV systems co-located with sheep grazing, PV systems co-located with pollinator friendly fields and PV systems co-located with crops. We also conducted extensive sensitivity analysis around different PV system design parameters given the nascent stage of this industry.
In March 2019, Pacific Northwest National Laboratory (PNNL) and National Renewable Energy Laboratory (NREL) held a workshop to discuss the characterization of hydropower resources within electric power system models. The workshop took place at the Western Electricity Coordinating Council in Salt Lake City, Utah, and was sponsored by the Water Power Technologies Office of the US Department of Energy. The intention of the workshop is to support the federal energy research initiative HydroWIRES. The Initiative has a specific technical objective to advance the representation of hydropower resources in relevant water and power models and to address the seams between the two. This report describes the workshop, contributions from attendees, a summary of the findings of the event and proposed next steps. The themes and recommendations from this workshop have provided foundational guidance for future research and program strategy.
Floating photovoltaic solar energy installations (FPVs) represent a new type of water surface use, potentially sparing land needed for agriculture and conservation. However, standardized metrics for the land sparing and resource use efficiencies of FPVs are absent. These metrics are critical to understanding the environmental and ecological impacts that FPVs may potentially exhibit. Here, we compared techno-hydrological and spatial attributes of four FPVs spanning different climatic regimes. Next, we defined and quantified the land sparing and water surface use efficiency (WSUE) of each FPV. Lastly, we coined and calculated the water surface transformation (WST) using generation data at the world’s first FPV (Far Niente Winery, California). The four FPVs spare 59,555 m2 of land and have a mean land sparing ratio of 2.7:1 m2 compared to ground-mounted PVs. Mean direct and total capacity-based WSUE is 94.5 ± 20.1 SD Wm−2 and 35.2 ± 27.4 SD Wm−2, respectively. Direct and total generation-based WST at Far Niente is 9.3 and 13.4 m2 MWh−1 yr−1, respectively; 2.3 times less area than ground-mounted utility-scale PVs. Our results reveal diverse techno-hydrological and spatial attributes of FPVs, the capacity of FPVs to spare land, and the utility of WSUE and WST metrics.
Electric power system planners utilize a variety of planning tools to inform decisions concerning generation and transmission additions to the electric grid, the need for operational changes, and to evaluate potential stressors on the system. Numerous factors contribute to the planning process including projected fuel and technology costs, policy and load profiles. There is also a growing recognition of the interdependency of the electric grid with other natural and engineered systems. Here we explore how future climate change and hydropower operability might influence decisions related to electricity capacity expansion planning and operations. To do so we assemble a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on future water supply for thermoelectric and hydropower generation. Separately, temperature impacts on electricity load are evaluated. Together, these climate factors spatially constrain a capacity expansion model that projects generation and transmission additions to the grid. The projected new capacity-builds are then evaluated on their operations, reliability, and cost under average and extreme climate conditions using production cost modeling. This coupled framework is demonstrated on the electric grid in the Western U.S., supporting capacity expansion planning by WECC, the North American Electric Reliability Corporation (NERC) regional entity responsible for reliability assurance of the Western Interconnection. This region was selected in part because the West is unique in that it has high potential for renewable penetrations and is experiencing large retirements/displacements of baseload resources, primarily coal, leading to possible operational challenges in terms of changing resource mix and the need for resource flexibility. Toward this challenge, planning scenarios encompass a range of alternative energy, climate and drought futures. In this context we explore answers to two strategic questions: 1) How does changing climate influence electricity expansion planning (generation and transmission) and future operations, including type and capacity of new builds, system reliability, cost and environmental impacts? 2) How does the representation of hydropower in the modeling framework influence the evaluation of bulk power system operations? Results indicate that climate has a measurable influence on recommendations concerning the capacity, type and location of new generation and transmission additions, with up to 17 GW additional capacity needed by 2038 to meet peak loads (~6.6% increase over capacity-builds based on historical climate). The extent of additional infrastructure needs is strongly influenced by future water availability for hydropower and the potential deployment of demand response technologies. Systems designed for future climate conditions were found to maintain high system reliability under a range of electricity and water availability scenarios (including significant drought), with minimal system curtailments. Additional capacity needs due to higher load tend to increase cumulative 20-year investment and operating costs by $\$$5-$\$$17 billion and generation costs increase by 9 to 19%. Finally, changing the representation of hydropower flexibility has a relatively small influence on capacity expansion in the Western Interconnection through 2038, but hydropower flexibility impacts generation costs to a similar extent as climate.
Abstract not provided.
Solar photovoltaic (PV) technology is being deployed at an unprecedented rate. However, utility-scale solar energy development is land intensive and its large-scale installation can have negative impacts on the environment. In particular, solar energy infrastructure can require extensive landscape modification that transforms soil ecological functions, thereby impacting hydrologic, vegetative, and carbon dynamics. However, reintroducing native vegetation to solar PV sites may be a means of restoring their soils. To this end, we investigated critical soil physical and chemical parameters at a revegetated photovoltaic array and an adjacent reference grassland in Colorado, United States. Seven years after revegetation, we found that carbon and nitrogen remained lower in the PV soil than in the reference soil and contained a greater fraction of coarse particles. We also found that the PV modules introduced heterogeneity in the soil moisture distribution, with precipitation accumulating along the lower edges of panels. The redistribution of soil moisture by panel arrays could potentially be used in concert with planting strategies to maximize plant growth or minimize soil erosion, and should be considered when evaluating the potential to co-locate vegetation with solar infrastructure.
As large electricity consumers, water distribution system (WDS) pumping stations have the potential to become meaningful participants in demand response (DR) programs. The authors propose an optimization framework for assessing the DR capacity of a WDS and identifying the optimal bidding strategy for maximizing WDS revenue in the DR spot market. The proposed mixed integer linear programming (MILP) model overcomes computational constraints of previous DR optimization models by adopting a preprocessing procedure to minimize the number of binary variables and implementing a convex relaxation technique to linearize the hydraulic equations. The proposed MILP model also explicitly accounts for varying levels of risk tolerance of WDS operators by varying the recovery period over which pumping returns to business-as-usual operation. The optimization framework is implemented on a skeletonized 48-node WDS model that includes 7 pumps, 6 tanks, and 39 pipes. Using a simulated DR event and water consumption profile, the authors derive the optimal DR supply curves (i.e., compensation price versus load curtailment quantity) and revenue potential of the WDS under six scenarios for DR participation.
Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.
These data files provide MOSART-WM monthly flows at hydropower dam and HUC4 outlet locations. The flows are transformed into monthly generation constraints scenarios for hydro (generation potential) and thermal power plants (derated capacity) for input to the PLEXOS model. Contact: Sean Turner , Nathalie Voisin Authors: Nathalie Voisin, Ana Dyreson, Tao Fu, Matt O'Connell, Sean Turner, Tian Zhou, Jordan Macknick
These data files provide contemporary (2010) bulk electricity grid operations and transmission flow as simulated by PLEXOS and informed by historical and future generation constraints scenarios as informed by historical and future water availability at hydro and thermoelectric plants. Contact: Ana Dyreson , Nathalie Voisin Authors: Nathalie Voisin, Ana Dyreson, Tao Fu, Matt O'Connell, Sean Turner, Tian Zhou, Jordan Macknick
Abstract. Managing water resources in a complex adaptive natural–human system is a challenge due to the difficulty of modeling human behavior under uncertain risk perception. The interaction between human-engineered systems and natural processes needs to be modeled explicitly with an approach that can quantify the influence of incomplete/ambiguous information on decision-making processes. In this study, we two-way coupled an agent-based model (ABM) with a river-routing and reservoir management model (RiverWare) to address this challenge. The human decision-making processes is described in the ABM using Bayesian inference (BI) mapping joined with a cost–loss (CL) model (BC-ABM). Incorporating BI mapping into an ABM allows an agent's psychological thinking process to be specified by a cognitive map between decisions and relevant preceding factors that could affect decision-making. A risk perception parameter is used in the BI mapping to represent an agent's belief on the preceding factors. Integration of the CL model addresses an agent's behavior caused by changing socioeconomic conditions. We use the San Juan River basin in New Mexico, USA, to demonstrate the utility of this method. The calibrated BC-ABM–RiverWare model is shown to capture the dynamics of historical irrigated area and streamflow changes. The results suggest that the proposed BC-ABM framework provides an improved representation of human decision-making processes compared to conventional rule-based ABMs that do not take risk perception into account. Future studies will focus on modifying the BI mapping to consider direct agents' interactions, up-front cost of agent's decision, and upscaling the watershed ABM to the regional scale.
We report that floating photovoltaic (FPV) systems, also called floatovoltaics, are a rapidly growing emerging technology application in which solar photovoltaic (PV) systems are sited directly on water. The water-based configuration of FPV systems can be mutually beneficial: Along with providing such benefits as reduced evaporation and algae growth, it can lower PV operating temperatures and potentially reduce the costs of solar energy generation. Although there is growing interest in FPV, to date there has been no systematic assessment of technical potential in the continental United States. We provide the first national-level estimate of FPV technical potential using a combination of filtered, large-scale datasets, site-specific PV generation models, and geospatial analytical tools. We quantify FPV co-benefits and siting considerations, such as land conservation, coincidence with high electricity prices, and evaporation rates. Our results demonstrate the potential of FPV to contribute significantly to the U.S. electric sector, even using conservative assumptions. A total of 24?419 man-made water bodies, representing 27% of the number and 12% of the area of man-made water bodies in the contiguous United States, were identified as being suitable for FPV generation. FPV systems covering just 27% of the identified suitable water bodies could produce almost 10% of current national generation. Lastly, many of these eligible bodies of water are in water-stressed areas with high land acquisition costs and high electricity prices, suggesting multiple benefits of FPV technologies.
Abstract not provided.
Abstract not provided.
Water is a critical resource in the production of electric power. The purpose of this plan is to extend support to the nation's three electric interconnections toward integrating water issues into their long-range transmission planning. This continued support is at the request of the interconnections. The proposed program leverages prior support as well as that of other similarly focused efforts funded across the Department of Energy (DOE). The effort will utilize a project team lead by Sandia National Laboratories and supported by Argonne National Laboratory, National Renewable Energy Laboratory, and Pacific Northwest National Laboratory. The activities recorded here are meant to provide a menu of potential projects that could be implemented as available resources permit.