Search NASA⌕ Search

Engineering topics

Madden, N.

Publications and source records attributed to Madden, N..

The In Situ Ion Irradiation Toolbox: Time-Resolved Structure and Property Measurements

Abstract The dynamic interactions of ions with matter drive a host of complex evolution mechanisms, requiring monitoring on short spatial and temporal scales to gain a full picture of a material response. Understanding the evolution of materials under ion irradiation and displacement damage is vital for many fields, including semiconductor processing, nuclear reactors, and space systems. Despite materials in service having a dynamic response to radiation damage, typical characterization is performed post-irradiation, washing out all information from transient processes. Characterizing active processes in situ during irradiation allows the mechanisms at play during the dynamic ion-material interaction process to be deciphered. In this review, we examine the in situ characterization techniques utilized for examining material structure, composition, and property evolution under ion irradiation. Covering analyses of microstructure, surface composition, and material properties, this work offers a perspective on the recent advances in methods for in situ monitoring of materials under ion irradiation, including a future outlook examining the role of complementary and combined characterization techniques in understanding dynamic materials evolution.

36 MATERIALS SCIENCE↗

Recrystallization suppression through dispersion-strengthening of tungsten

Tungsten is the material of choice for the divertor region of future nuclear fusion reactors, an environment that will expose plasma-facing components (e.g. divertor, etc...) to high temperatures and transient high heat flux events. Under these conditions, recrystallization and grain growth of tungsten can occur, leading to undesirable microstructural and mechanical property changes. Therefore, there is a need to raise the recrystallization temperature of tungsten and limit the kinetics of the recrystallization and grain growth processes. In this work, we examine the effect of different types (TiC vs. TaC vs. ZrC) and different concentrations (1.1 vs. 5 vs. 10 wt.%) of dispersed second phase particles in a tungsten matrix on the high temperature performance. Additionally, the addition of second-phase particles effectively increases the temperature of and time for recrystallization and slow grain growth; however, the addition of a high weight fraction of particles alters the surface chemistry, which may impact subsequent plasma-surface interactions. These results show that the addition of small concentrations of dispersed particles can be effectively employed in tungsten to raise the upper operating temperature limit for tungsten in a fusion reactor.

36 MATERIALS SCIENCE↗

X-Ray and Gamma-Ray Astronomy with NTD Germanium-based Microcalorimeters

We report on the performance of our NTD-Ge microcalorimeters. To date, the spectral resolution for x-ray and gamma-ray lines from radioactive sources and laboratory plasmas is 4.8 eV in the entire 1 - 6 keV band and 52 eV at 60 keV. Technical details responsible for this performance are presented as well as an innovative electro-thermal approach for enhancing count-rate capability.

Silver, E.↗

B-MINE: The Balloon-Borne Microcalorimeter Nuclear Line Explorer

B-MINE is a concept for a balloon mission designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the extent and velocity distribution of the 44Ti emitting region. The payload introduces the concept of focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics. B-MINE has a thin, plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3 sigma sensitivity in 10 (exp 6) s of 3.3 x 10(exp -7) ph cm(exp -2) s(exp -1) at 68 keV. During the course of a long duration balloon flight, B-MINE could carry out a detailed study of the 44Ti emission line centroid and width in CAS A.

Silver, E.↗

The Constellation-X Focal Plane Microcalorimeter Array: An NTD-Germanium Solution

The hallmarks of Neutron Transmutation Doped (NTD) germanium cryogenic thermistors include high reliability, reproducibility, and long term stability of bulk carrier transport properties. Using micro-machined NTD Ge thermistors with integral 'flying' leads, we can now fabricate two-dimensional arrays that are built up from a series of stacked linear arrays. We believe that this modular approach of building, assembling, and perhaps replacing individual modules of detectors is essential to the successful fabrication and testing of large multi-element instruments. Details of construction are presented.

Beeman, J.↗

Laboratory Astrophysics and Microanalysis with NTD-Germanium-Based X-Ray Microcalorimeter

With the ability to create cosmic plasma conditions in the laboratory it is possible to investigate the dependencies of key diagnostic X-ray lines on density, temperature, and excitation conditions that exist in astrophysical sources with X-ray optics and a high resolution x-ray microcalorimeter. The same instrumentation can be coupled to scanning electron microscopes or x-ray fluorescence probes to analyze the elemental and chemical composition of electronic, biological, geological and particulate materials. We describe how our microcalorimeter and x-ray optics provide significantly improved capabilities for laboratory astrophysics and microanalysis.

Silver, E.↗

The Role of Boundary Layer Aerosol in the Vertical Development of Precipitation and Electrification: Another Look at the Contrast Between Lightning over Land and Over Ocean

Comparisons are made between the cloud condensation nuclei (CCN) concentration in the boundary layer and radar/electrical observations of the vertical development of precipitation and lightning in both the 'break period' and 'monsoon' regimes in tropical Brazil. The initial radar echoes and the maximum flash rates are found to be higher when the CCN concentration is higher, characteristic of the 'break period' conditions. One possible explanation for both observations is the survival of cloud droplets against coalescence and their attainment of the mixed phase region aloft.

Williams, E.↗

High-resolution spectral measurements of GRO J1655-40

Data from the transient gamma ray germanium detector taken during 1995 provide a limited ability to study the high resolution spectrum of the X-ray transient GRO J1655-40. During a two-day period around the peak intensity, the soft spectrum was measured and found to be consistent with a power law spectrum with photon index -3.0 +/- 0.2. No evidence was found for narrow spectral features in the 50 to 100 keV band or around 511 keV. The 3 sigma upper limit for a narrow emission line at 511 keV is 1.2 x 10(exp -2) phot/cu cm s.

intZand, J. J. M.↗

Feasibility of KTa(1-x)Nb(x)O3 as a dielectric or pyroelectric microcalorimeter

We are developing a dielectric microcalorimeter for X-ray spectroscopy. We will present the results of our measurement of the dielectric permittivity, the spontaneous polarization, and the pyroelectric coefficient of the mixed-crystal quantum ferroelectric KTa(1-x)Nb(x)O3 with a doping of x = 0.012, as a function of temperature and bias voltage across the device. The effects of surface layers on the permittivity and the pyroelectric coefficient are discussed. We also show the signal results from infrared LED and alpha-particle radiation.

Pfafman, T. E.↗

A new thermal sensor for X-ray microcalorimetry

A concept for a detector is introduced which exploits the significant temperature dependence of the dielectric constant in ferroelectric materials. The concept permits the use of a microcalorimeter without the resistive sensors which are associated with heat dissipation and increased Johnson noise in the electronic conversion circuit. General calorimeter features are listed, and the concepts related to dielectric calorimeters are discussed in terms of operational and detection advantages. The use of the device is delineated both theoretically and experimentally with the results of an operational dielectric material. The mixed-crystal quantum ferroelectric is employed and detects 6 MeV alpha particles while operating at 1.2 K in the first detection conducted. The temperature dependence of the dielectric constant in the materials allows for the elimination of resistive sensors in microcalorimeters, thereby improving the ultimate sensitivity of the instrument.

Silver, Eric↗

Test results of a prototype dielectric microcalorimeter

The initial development work on a dielectric microcalorimeter is presented. It focuses on the dielectric properties of the ferroelectric material KTa(1-x)Nb(x)O3 (KTN). Measurements of the temperature dependent dielectric constant are given together with the first alpha particle detection results from a prototype composite microcalorimeter operating at 1.3 K. A nonthermal mechanism for detecting 6 MeV alpha particles in a monolithic KTN sample is also reported.

Pfafman, T. E.↗