Search NASA⌕ Search

Engineering topics

Mahapatra, Kaveri

Publications and source records attributed to Mahapatra, Kaveri.

29 records · Page 2

Limitations in Advanced Measurement Systems: An Overview for Power Systems

Measurements have been an essential part of managing the electric power system from the beginning. Surprisingly, today’s measurements are not always particularly trustworthy. Countless factors can influence measurement in real-world conditions. In this report, we look at the measurement system as a comprehensive information acquisition system with complicated interdependencies setting the limiting factors and affecting system performance. The first chapter provides an overview of the whole system and introduces the key elements of the limitations checklist. The second part of the document is a component checklist for measurement system limitations that concisely describes effects, common remedies, and underlying factors.

42 ENGINEERING↗

Systems and methods for enhanced sequential power system model parameter estimation

A system for enhanced sequential power system model calibration is provided. The system is programmed to store a model of a device. The model includes a plurality of parameters. The system is also programmed to receive a plurality of events associated with the device, receive a first set of calibration values for the plurality of parameters, generate a plurality of sets of calibration values for the plurality of parameters, for each of the plurality of sets of calibration values, analyze a first event of the plurality of events using a corresponding set of calibration values to generate a plurality of updated sets of calibration values, analyze the plurality of updated sets of calibration values to determine a current updated set of calibration values, and update the model to include the current updated set of calibration values.

Wang, Honggang↗

Data-Driven PMU Noise Emulation Framework using Gradient-Penalty-Based Wasserstein GAN

Availability of phasor measurement unit (PMUs) data has led to research on data-driven algorithms for event monitoring, control and ensuring stability of the grid. Unavailability of infrequent critical event field PMU data with component failures is driving the need to generate realistic synthetic PMU data for research. The synthetic data from power system simulation software often neglect noise profiles of received phasors, thus creating some discrepancies between real PMU data and synthetic ones. To address this issue, this work presents an initial study on the noise characteristics of PMUs, as well as presenting models for recreating their unique noise signatures. The proposed method, utilizing the Wasserstein generative adversarial network with gradient penalty (WGAN-GP) architecture, provides an excellent benchmark for matching the noise distribution. One can use a well-learned GAN model to draw noise signatures from a distribution that seemingly mirrors the real PMU noise distribution, while also being able to be detached from the PMU data once the training is done. Based on the observed results and employed data-driven methodology, it is expected that the proposed methods can be adapted to replicate the behavior of other sensors, providing research and other applications with a tool for data synthesis and sensor characterization.

PMU↗

Grid Utility Asset Vulnerability Assessment (GUAVA) Software Tool

Increasing demand and changes in generation portfolios is pushing power grid to operate towards the limit. However, due to lack of analytical tools for understanding various scales of impact on grid, it is becoming more vulnerable to wide scale power outages and blackouts. A vulnerable grid operating at its limit can be easily disrupted by asset failures caused by devastating hurricanes which has been known to damage transmission and distribution lines along its track. In this direction, researchers have focused on determining these assets by conducting Monte Carlo simulations of hurricanes with uncertainties and collected a large set of simulation data. To determine the infrastructure updates necessary for mitigating wide scale impact of hurricanes on the grid, we propose a software tool named “Grid Utility Asset Vulnerability Analysis” (GUAVA) framework. GUAVA presents a novel data-driven probabilistic analytical approach to (1) post-process hurricane failure scenarios, (2) identify/rank assets that are most vulnerable and critical to failing and are associated with highest impact/risk, and (3) to inform system upgrade decisions & prioritization. Based on the observed results and employed data-driven methodology, it is expected GUAVA can be adapted to provide power system planners with a recommendation engine for making informed decisions to improve resilience of grid.

Mahapatra, Kaveri↗

Physics Informed Reinforcement Learning for Power Grid Control using Augmented Random Search

Wide adoption of deep reinforcement learning need to overcome several challenges in energy system domain, including scalability, learning from limited samples, and high-dimensional continuous state and action spaces. In this paper, we integrated physics-based information from the normal generator operation state formula in the reinforcement learning agent's neural network loss function, and applied an augmented random search agent to optimize the generator control under dynamic contingency. Simulation results demonstrated the reliability performance improvements in training speed, reward convergence, sampling efficiency, scalability, and transferability.

physics informed ML, Physics Informed Neural Netwo↗

Novel Data Driven Noise Emulation Framework using Deep Neural Network for Generating Synthetic PMU Measurements

Sensors play a critical role in supporting day-to-day grid operations and they are essential to operator’s decision-making process. Furthermore, sensors and sensor behaviors need to be emulated with grid simulations to perform modeling studies and to design cutting edge power systems applications. Ensuring the accurate behavior of these applications requires accurate emulation of sensors and pertinent signals. However, most grid simulators and modeling tools assume either zero error scenarios or simplistic noise models that may not always correlate to real-world sensors. To address the above issue, this work presents an initial study on the noise characteristics of phasor measurement units (PMUs), along with models for recreating their unique noise signatures. The proposed methods (both analytical and machine-learning-based) provide a substantial increase in a sensor’s model fidelity, a feature that can be leveraged by an end-user application to yield more accurate system representations. The proposed methods were then applied to micro PMU data from the EPFL microgrid campus to extract sensor noise profiles. This data was used to train a deep learning model, which was tested to emulate the noise characteristics present in actual signals. Based on the observed results and the employed data-driven methodology, the proposed methods may be adapted to replicate the behavior of other grid sensors and power new applications capable of detecting sensor degradation and eventual device failures in near real-time.

PMU, noise emulation, synthetic measurements, deep↗

Application of Chebyshev’s Inequality in Online Anomaly Detection Driven by Streaming PMU Data

The day-to-day operation of modern power systems is highly reliant on prompt and adequate situational-awareness. This can be achieved via various system monitoring functions such as anomaly detection, in which static thresholds are commonly utilized to distinguish the normal and the abnormal system states. However, a predetermined static threshold usually lacks the flexibility to adapt to unobserved scenarios. In this paper, we propose two self-adaptive synchrophasor data driven anomaly detection approaches based on Chebyshev’s Inequality. The proposed approaches have been evaluated with Kundur’s 2area system and Mini-WECC system. Experimental results verify that the proposed approaches can dynamically adapt to unprecedented scenarios, and detect anomalous events with lower false alarm rate compared to static threshold based detection.

24 POWER TRANSMISSION AND DISTRIBUTION↗