Search NASA⌕ Search

Engineering topics

Maier, E. J. R.

Publications and source records attributed to Maier, E. J. R..

Influence of peroxyacetyl nitrate (PAN) on odd nitrogen in the troposphere and lower stratosphere

Nonmethane hydrocarbon breakdown in the atmosphere produces aldehydes of which a fraction are transferred into peroxyacetyl nitrates (PAN) in the presence of NO and NO2. Since ethane is destroyed photochemically primarily above 1 km, PAN can be introduced into the upper troposphere and lower stratosphere without the need to be transported from the boundary layer where most hydrocarbons are destroyed and where PAN may be lost due to thermal decomposition and heterogeneous loss. Mixing ratios of ethane in the lower troposphere increase by a factor of 4-8 from equatorial to northern mid-latitudes. This difference is directly translatable into a PAN latitude gradient. At mid-latitudes the concentration of PAN below 20 km is 0.1 ppb comparable to and in some instances larger than predicted HO2NO2 mixing ratios. Like HO2NO2 and HNO3, PAN serves as a reservoir for odd nitrogen.

Aikin, A. C.↗

Artificial aurora conjugate to a rocket-borne electron accelerator

An accelerator intended to send electron beams upward along an L = 1.24 magnetic field line was flown from a rocket launched from Kauai, Hawaii, on October 15, 1972. Though the intent was to produce several hundred observable auroral streaks in the Southern Hemisphere, imaging instruments operated there aboard jet aircraft detected only a single aurora. Produced by a 0.155-A beam of energy 22.8 keV, the aurora was of expected brightness and had a diameter (210 + or - 50 m) somewhat larger than expected and an altitude (top 116 + or - 2 km; bottom 92 + or - 2 km) higher than expected.

Davis, T. N.↗

Balloon-borne photoionization mass spectrometer for measurement of stratospheric gases

A balloon-borne photoionization mass spectrometer used to measure stratospheric trace gases is described. Ions are created with photons from high-intensity krypton discharge lamps and a quadrupole mass analyzer is employed for ion identification. Differential pumping is achieved with liquid helium cryopumping. To insure measurement of unperturbed stratospheric air, the entire system is contained in a sealed gondola and the atmospheric sample is taken some distance away during descent. The photoionization technique allows the detection of a low ionization potential constituent, such as nitric oxide, at less than a part in one billion in the presence of the major atmospheric gases and their isotopes. Operation of the mass spectrometer system was demonstrated during a daytime flight from Palestine, Texas on 26 April 1977. The sensitivity achieved and the unique selectivity afforded by this technique offer a capability for trace constituent measurement not possible with the more conventional electron impact ionization approach.

Aikin, A. C.↗