Search NASA⌕ Search

Engineering topics

Majeski, R.

Publications and source records attributed to Majeski, R..

Integration of fixed-frequency and FM-CW (frequency-modulated continuous-wave) reflectometers for coincident turbulence measurements on LTX- β (Lithium Tokamak eXperiment- β )

The fixed-frequency and frequency-modulated continuous-wave (FM-CW) reflectometers on LTX-β (Lithium Tokamak eXperiment-β) have been configured to use the same transmission lines and antenna arrays for coincident views of the core and edge plasma. The fixed-frequency channels (13.1–20.5 and 20–40 GHz, tunable between discharges) provide time-resolved measurements of density fluctuations, while the FM-CW channels (13.1–20.2 and 19.5–33.5 GHz) measure the density profile and fluctuations, with high spatial resolution and a sampling rate determined by the frequency sweep interval (5 μs). Data from both reflectometers are synchronously acquired to simultaneously leverage the wide bandwidth and high spatial resolution of the respective systems. Experiments showed that mutual crosstalk interference is momentary and does not diminish the capability of either system. Spectral analysis indicated broad power spectra (several hundreds of kHz) and suggests that the signals from the FM-CW system are consistent with under-sampled fixed-frequency signals. Radial correlations were explored using data from the two reflectometers, as well as from the FM-CW system alone. The core channels showed high levels of agreement between these two comparisons, suggesting that the data from the reflectometers are interchangeable for statistical estimates. For the edge channels, comparisons using data from the FM-CW reflectometer alone showed significant decorrelation due to time lag caused by the finite frequency up-sweep duration. Alternatively, this effect is eliminated when cross-correlating data from the different reflectometers. Finally, these results highlight the advantages of operating the fixed-frequency and FM-CW reflectometers in this manner, where the combined system can overcome the limitations of each separate system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

Spectroscopic measurement of increases in hydrogen molecular rotational temperature with plasma-facing surface temperature and due to collisional-radiative processes in tokamaks

Abstract Spatially resolved rotational temperature of ground state hydrogen molecules desorbed from plasma-facing surface was measured in QUEST, LTX-β, and DIII-D tokamaks, and the increases of the rotational temperature with the surface temperature and due to collisional-radiative processes in the plasmas were evaluated. The increase due to collisional-radiative processes was calculated by solving rate equations considering electron and proton collisional excitation and deexcitation and spontaneous emission. The calculation results suggest a high sensitivity for the rotational temperature to electron and proton densities, but a negligible sensitivity to the electron, proton, and surface temperatures. In the three tokamaks with different plasma parameters and plasma-facing surface materials, the spatial profile of the rotational temperature was estimated using Fulcher-α emission lines (600–608 nm). In QUEST, the spatial profile of the rotational temperature was estimated from spatially resolved spectra. In the other tokamaks, the rotational temperature was evaluated assuming a single point emission with a location determined from the Fulcher-α emission profile as measured with a filtered camera. In metal-walled devices QUEST and LTX-β, the rotational temperature increased with the surface temperature, and the calculated collisional-radiative increase is consistent with measured increase assuming that the rotational temperature at the surface is approximately 500–600 K higher than the surface temperature. In DIII-D with carbon walls, a larger collisional-radiative increase than the other tokamaks was observed because of the higher density leading to a large difference from the calculated increase compared to the other smaller tokamaks. Measurement of the Fulcher-α emission profile with higher spatial resolution in DIII-D may reduce the difference and reveal the effect of the surface temperature on the rotational temperature. These results show the increases in the rotational temperature with the surface temperature and due to the collisional-radiative processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recycling Measurements for the Lithium Tokamak Experiment

The lithium tokamak experiment (LTX) is a spherical torus designed to investigate a low-recycling wall regime for magnetically confined plasmas. Traditional measurements of recycling using Dα emission are not feasible in LTX due to reflections off the plasma-facing-components: stainless-steel shell, liquid lithium layer, and molybdenum limiters. Since lithium has low VUV reflectivity, LTX will use Lyman-α emission to measure particle recycling. LTX will use 10- and 20-channel AXUV diode arrays with Lyman-α filters to view recycling off the inboard and outboard shells. A single detector views recycling off a limiter. Measurements will be used with neutral modeling to calculate recycling and neutral deposition. To investigate the performance of an AXUV diode with directly-deposited filter, measurements were obtained with this detector and a visible detector viewing a calibration plasma then compared with emission calculated using a collisional-radiative model.

Physics - Plasma physics↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral beam prompt loss in LTX-β

Prompt loss of beam injected fast ions approaches 100% in lithium tokamak experiment-beta (LTX-β) discharges, though significantly improved confinement is expected for the higher current plasmas made available by a recent upgrade to the Ohmic heating power supply. Modeling of fast ions using TRANSP/NUBEAM finds a maximum coupled beam fraction of 76% at the near-term limits of the LTX-β operating space. The full ion orbit code POET is employed to validate NUBEAM results against possible non-adiabatic effects on fast ion orbits, but corrections to the prompt loss fraction due to collisionless transport are found to be small. The graphical method code CONBEAM is used to investigate the topology of fast ion phase space as it relates to neutral beam deposition, and counter-injected NBI is considered as a way to access a region of high field side beam deposition. A metric is developed within the CONBEAM using a beam filament model to estimate the prompt loss fraction and shown to agree well with both POET and NUBEAM, enabling near real-time analysis and potential feedback to operators between plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal plasma acceleration due to NBI fast ion losses in LTX- β

The recent Lithium Tokamak Experiment-Beta (LTX- β ) upgrade includes the addition of neutral beam injection (NBI) in the same direction as the plasma current (co- I P ) and a new toroidal Mirnov array for MHD characterization. In initial NBI experiments, a spontaneously rotating n = 1 MHD mode is seen to accelerate during NBI in the counter-beam direction, accompanied by a rise in electron density consistent with the beam-injected inventory but without a clear increase in plasma pressure. Together with analytic and numerical modeling of beam optics and fast ion confinement, these observations indicate the prompt loss of all or nearly all beam ions. However, the same modeling also suggests that planned upgrades to the Ohmic heating system should provide the fast ion confinement necessary for beam heating and core fueling. Here, a simple analytic model relates the momentum confinement time τ Φ to the observed evolution of mode rotation due to the combination of NBI momentum coupling, fast ion loss $\vec{J}\times\vec{B}$, and anomalous viscous torques, yielding τ Φ values consistent with past measurements of electron energy confinement time τ E,e .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The development of a Sustained High Power Density (SHPD) facility

A Sustained High Power Density (SHPD) facility is being planned within the U.S. as a non DT device which can be a bridge to a Compact Fusion Pilot Plant (CFPP) DT operated facility with the future capacity to produce a levelised cost of electricity at a rate competitive with current power generating systems. To accomplish this a review of ITER cost data and recent next step physics/engineering studies that promoted technology development, physics enhancements and innovated configuration improvements that increase operating availability have been injected into a proposed PPPL SHPD design. Much of the physics and engineering design basis for this effort centers on a series of ST studies carried out in recent years attempting to maximize the low aspect ratio (AR) ST performance within realistic engineering constraints of this compact fusion device. One issue found in the low AR design is the lack of volt-seconds generated by a small central solenoid that resides in the available space left after sizing the TF structure to support the high current density/HTS TF coil. Although not required in a larger pilot plant device, a solenoid wrapped around the plasma side of the SC TF coil was considered for the small low aspect ratio SHPD device. Adding a solenoid to the plasma side of the TF imposes a major change to the device configuration – a change which has been found to have cost and assembly issues when compared with an OH solenoid located at the machine center. Finally, the inclusion of a liquid metal first wall divertor system, the integration of local pairs of outboard DCLL blanket segments and a summary of physics performance conditions will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple vacuum suitcase for enabling plasma facing component characterization in fusion devices

We have demonstrated a vacuum suitcase to transport samples in vacuo to a surface analysis station for characterization of tokamak plasma facing components (PFCs). This technique enables surface analysis at powerful, dedicated stations that are not encumbered by design constraints imposed on them by a tokamak. The vacuum suitcase is an alternative solution to characterizing PFCs using diagnostics that are designed and built around a tokamak. The vacuum suitcase, called the Sample Exposure Probe (SEP), features mobile ultra-high vacuum pumping. Active pumping under high vacuum enables sample transfer between the Lithium Tokamak eXperiment-β (LTX-β) and a high resolution X-ray Photoelectron Spectroscopy (XPS) system that is situated close by. A thermocouple inserted in the back of the sample head measures heat flux from the plasma during exposure, and together with a button heater, allows the sample to match the LTX-β PFCs in high temperature operations. As vacuum conditions are better during transfer and analysis than in the tokamak, less contamination is introduced to the samples. XPS scans on a dedicated analysis station enable peak identification due to higher resolution and signal to noise ratio. A similar probe could be implemented for other fusion devices. As a result, the SEP is the first vacuum suitcase implementation for fusion applications that incorporates active pumping.

47 OTHER INSTRUMENTATION↗