Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Toward using collective x-ray Thomson scattering to study C–H demixing and hydrogen metallization in warm dense matter conditions

The insulator–metal transition in liquid hydrogen is an important phenomenon to understand the interiors of gas giants, such as Jupiter and Saturn, as well as the physical and chemical behavior of materials at high pressures and temperatures. Here, the path toward an experimental approach is detailed based on spectrally resolved x-ray scattering, tailored to observe and characterize hydrogen metallization in dynamically compressed hydrocarbons in the regime of carbon–hydrogen phase separation. With the help of time-dependent density functional theory calculations and scattering spectra from undriven carbon samples collected at the European x-ray Free-Electron Laser Facility (EuXFEL), we demonstrate sufficient data quality for observing C–H demixing and investigating the presence of liquid metallic hydrogen in future experiments using the reprated drive laser systems at EuXFEL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of an x-ray Raman spectroscopy setup to study warm dense carbon at the high energy density instrument of European XFEL

We present a proof-of-principle study demonstrating x-ray Raman Spectroscopy (XRS) from carbon samples at ambient conditions in conjunction with other common diagnostics to study warm dense matter, performed at the high energy density scientific instrument of the European x-ray Free Electron Laser (European XFEL). We obtain sufficient spectral resolution to identify the local structure and chemical bonding of diamond and graphite samples, using highly annealed pyrolytic graphite spectrometers. Due to the high crystal reflectivity and XFEL brightness, we obtain signal strengths that will enable accurate XRS measurements in upcoming pump–probe experiments with a high repetition-rate, where the samples will be pumped with high-power lasers. Molecular dynamics simulations based on density functional theory together with XRS simulations demonstrate the potential of this technique and show predictions for high-energy-density conditions. Our setup allows simultaneous implementation of several different diagnostic methods to reduce ambiguities in the analysis of the experimental results, which, for warm dense matter, often relies on simplifying model assumptions. The promising capabilities demonstrated here provide unprecedented insights into chemical and structural dynamics in warm dense matter states of light elements, including conditions similar to the interiors of planets, low-mass stars, and other celestial bodies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

Using Diffuse Scattering to Observe X-Ray-Driven Nonthermal Melting

We present results from the SPring-8 Angstrom Compact free electron LAser (SACLA) XFEL facility, using a high intensity ($\sim\!10^{20}\,$W/cm$^2$) X-ray pump X-ray probe scheme to observe changes in the ionic structure of silicon induced by X-ray heating of the electrons. By avoiding Laue spots in the scattering signal from a single crystalline sample, we observe a rapid rise in diffuse scattering, which we attribute to a loss of lattice order and a transition to a liquid state within 100 fs of irradiation, a timescale which agrees well with first principles simulations, but is faster than that predicted by purely inertial behavior. This method is capable of observing liquid scattering without masking or filtering of signal from the ambient solid, allowing the liquid structure to be measured throughout and beyond the phase change.

Hartley, Nicholas J.↗

The solar vector magnetograph of the Okayama Astrophysical Observatory

The vector magnetograph of the Okayama Astrophysical Observatory is fed to the 65 cm solar coude telescope with a 10 m Littrow spectrograph. The polarimeter put at the telescope focus analyzes the incident polarization. Photomultipliers (PMT) at the exit of the spectrograph pick up the modulated light signals and send them to the electronic controller. The controller analyzes frequency and phase of the signal. The analyzer of the polarimeter is a combination of a single wave plate rotating at 40 Hz and a Wallaston prism. Incident linear and circular polarizations are modified at four times and twice the rotation frequency, respectively. Two compensators minimize the instrumental polarization, mainly caused by the two tilt mirrors in the optical path of the telescope. The four photomultipliers placed on the wings of the FeI 5250A line give maps of intensity, longitudinal field and transverse field. The main outputs, maps of intensity, and net linear and circular polarizations in the neighboring continuum are obtained by the other two monitor PMTs.

Makita, M.↗

Comparisons of simultaneous vector magnetograms

Simultaneous vector magnetograms were obtained with the different magnetographs of the Okayama Astrophysical Observatory and the Sayan Mountain Observatory in October 1983. The data obtained show a good correspondence in general. The comparison makes clear something on the measuring accuracy of each magnetograph. Good correspondence is shown in circular and linear polarizations, and, in and near sunspots, of the velocity field. The azimuth of the magnetic fields show good agreement.

Makita, M.↗