Search NASA⌕ Search

Engineering topics

Makita, Mikako

Publications and source records attributed to Makita, Mikako.

X-ray induced grain boundary formation and grain rotation in Bi 2 Se 3

Optimizing grain boundary characteristics in polycrystalline materials can improve their properties. Many processing methods have been developed for grain boundary manipulation, including the use of intense radiation in certain applications. Here, in this work, we used X-ray free electron laser pulses to irradiate single-crystalline bismuth selenide (Bi 2 Se 3 ) and observed grain boundary formation and subsequent grain rotation in response to the X-ray radiation. Our observations with simultaneous transmission X-ray microscopy and X-ray diffraction demonstrate how intense X-ray radiation can rapidly change size and texture of grains.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of mosaic crystal instrument functions on x-ray Thomson scattering diagnostics

Mosaic crystals, with their high integrated reflectivities, are widely employed in spectrometers used to diagnose high energy density systems. X-ray Thomson scattering (XRTS) has emerged as a powerful diagnostic tool of these systems, providing in principle direct access to important properties such as the temperature via detailed balance. However, the measured XRTS spectrum is broadened by the spectrometer instrument function (IF), and without careful consideration of the IF one risks misdiagnosing system conditions. Here, we consider in detail the IF of 40 and 100 μm mosaic Highly Annealed Pyrolytic Graphite crystals, and how the broadening varies across the spectrometer in an energy range of 6.7–8.6 keV. Notably, we find a strong asymmetry in the shape of the IF toward higher energies. As an example, we consider the effect of the asymmetry in the IF on the temperature inferred via XRTS for simulated 80 eV CH plasmas and find that the temperature can be overestimated if an approximate symmetric IF is used. We, therefore, expect a detailed consideration of the full IF will have an important impact on system properties inferred via XRTS in both forward modeling and model-free approaches.

47 OTHER INSTRUMENTATION↗

Ion emission from warm dense matter produced by irradiation with a soft x-ray free-electron laser

Here we report on an experiment performed at the FLASH2 free-electron laser (FEL) aimed at producing warm dense matter via soft x-ray isochoric heating. In the experiment, we focus on study of the ions emitted during the soft x-ray ablation process using time-of-flight electron multipliers and a shifted Maxwell–Boltzmann velocity distribution model. We find that most emitted ions are thermal, but that some impurities chemisorbed on the target surface, such as protons, are accelerated by the electrostatic field created in the plasma by escaped electrons. The morphology of the complex crater structure indicates the presence of several ion groups with varying temperatures. We find that the ion sound velocity is controlled by the ion temperature and show how the ion yield depends on the FEL radiation attenuation length in different materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray Free Electron Laser-Induced Synthesis of ε -Iron Nitride at High Pressures

The ultrafast synthesis of ε-Fe 3 N 1+x in a diamond-anvil cell (DAC) from Fe and N 2 under pressure was observed using serial exposures of an X-ray free electron laser (XFEL). When the sample at 5 GPa was irradiated by a pulse train separated by 443 ns, the estimated sample temperature at the delay time was above 1400 K, confirmed by in situ transformation of α- to γ-iron. Ultimately, the Fe and N 2 reacted uniformly throughout the beam path to form Fe 3 N 1.33 , as deduced from its established equation of state (EOS). We thus demonstrate that the activation energy provided by intense X-ray exposures in an XFEL can be coupled with the source time structure to enable exploration of the time-dependence of reactions under high-pressure conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Double grating shearing interferometry for X-ray free-electron laser beams

The advancements in bright and coherent X-ray free-electron lasers (XFEL) have in the last decade revolutionized diverse fields of study, leading to an ever-increasing demand in more intense X-ray pulses. The accurate knowledge of the wavefront and the focal profile of such pulses ultimately dictates much of the experimental outcome.Herewe present a singleshot shearing interferometry method to measure the wavefront of a focused hardXFELpulse.Twoidentical transmission gratings are placed near the focus, and the interference pattern of overlapping diffraction orders is analyzed, resulting in a two-dimensional reconstruction of the X-ray wavefront. The spatial resolution and wavefront sensitivity can be tuned insitu during the measurement. The method is non-invasive (i.e., the zeroth order or transmitted pulse is not modified in intensity or profile), allowing for either a simultaneous intensity measurement at high resolution or a fully characterized transmitted pulse for general experimental use.

47 OTHER INSTRUMENTATION↗