Search NASA⌕ Search

Engineering topics

Malone, R. M.

Publications and source records attributed to Malone, R. M..

Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility

Fusion reaction history and ablator areal density measurements for Inertial Confinement Fusion experiments at the National Ignition Facility are currently conducted using the Gamma Reaction History diagnostic (GRH_6m). Future Gas Cherenkov Detectors (GCDs) will ultimately provide ~100x more sensitivity, reduce the effective temporal response from ~100 to ~10 ps, and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH_6m. The first phase toward next generation GCDs consisted of inserting the existing coaxial GCD-3 detector into a reentrant well which puts it within 4 m of the implosion. Reaction history and ablator gamma measurement results from this Phase I are discussed. These results demonstrate viability for the follow-on Phases of (II) the use of a revolutionary new pulse-dilation photomultiplier tube to improve the effective measurement bandwidth by >10x relative to current PMT technology; and (III) the design of a NIF-specific “Super” GCD which will be informed by the assessment of the radiation background environment within the well described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Mercury pulsed power x-ray source spectrum using multichannel density aerogel Cherenkov detectors

The Aerogel Cherenkov Detector for Cygnus (ACD/C) is a time-dependent, x-ray spectral detector that uses SiO 2 aerogels spanning an index of refraction (n = 1.02–1.07) corresponding to a 1.1–2.3 MeV x-ray energy threshold. The ACD/C was developed for pulsed power x-ray sources like Cygnus located at the Nevada National Site and Mercury located at the Naval Research Laboratory (NRL). Aerogels sit between the measurement capabilities of gas (>2 MeV) and solids such as fused silica (>0.3 MeV). The detector uses an aluminum converter to Compton scatter incoming x-rays and create relativistic electrons, which produce Cherenkov light in an aerogel or a fused silica medium. The ACD/C was fielded at the NRL when Mercury was tuned to produce up to 4.8 MeV endpoint bremsstrahlung. Despite a high radiation and electromagnetic interference background, the ACD/C was able to achieve high signal over noise across five aerogel densities and fused silica, including a signal to noise for a 1.1 MeV aerogel threshold. Previous experiments at Cygnus observed a signal that was comparable to the noise (1×) at the same threshold. The ACD/C observed time-resolved rise and fall times for different energy thresholds of the photon spectrum. Finally, Monte Carlo simulations of the ACD/C’s aerogel response curves were folded with a simulation of Mercury’s photon energy spectrum and agree within the error to the observed result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the National Ignition Facility (invited)

The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ~100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ~10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved Measurements of Cygnus X-ray Production Using Aerogel Cherenkov Detector

Aerogel Cherenkov Detector for Cygnus (ACD/C) has been developed to provide time-dependent x-ray spectral information from Cygnus – an intense flash x-ray source operated at the Nevada National Security Site. Time-resolved Cygnus x-ray signals were measured at three energy thresholds: 1.3 MeV (by 197 mg/cc aerogel), 1.1 MeV (by 260 mg/cc aerogel), and 0.3 MeV (by quartz). ACD/C data qualitatively suggest that the high-energy x-ray peak exists on a shorter timescale than the Cygnus voltage or current pulse. A time-dependent, x-ray spectral information can improve the understanding of the physics of dense objects radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrum

An aerogel Cherenkov detector is proposed to measure the X-ray energy spectrum from the Cygnus—intense flash X-ray source operated at the Nevada National Security Site. An array of aerogels set at a variety of thresholds between 1 and 3 MeV will be adequate to map out the bremsstrahlung X-ray production of the Cygnus, where the maximum energy of the spectrum is normally around 2.5 MeV. In addition to the Cherenkov radiation from aerogels, one possible competing light-production mechanism is optical transition radiation (OTR), which may be significant in aerogels due to the large number of transitions from SiO{sub 2} clusters to vacuum voids. To examine whether OTR is a problem, four aerogel samples were tested using a mono-energetic electron beam (varied in the range of 1–3 MeV) at NSTec Los Alamos Operations. It was demonstrated that aerogels can be used as a Cherenkov medium, where the rate of the light production is about two orders magnitude higher when the electron beam energy is above threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Next Generation Gamma-Ray Cherenkov Detectors for the National Ignition Facility

The newest generation of Gas Cherenkov Detector (GCD-3) employed in Inertial Confinement Fusion experiments at the Omega Laser Facility has provided improved performance over previous generations. Comparison of reaction histories measured using two different deuterium-tritium fusion products, namely gamma rays using GCD and neutrons using Neutron Temporal Diagnostic (NTD), have provided added credibility to both techniques. GCD-3 is now being brought to the National Ignition Facility (NIF) to supplement the existing Gamma Reaction History (GRH-6m) located 6 m from target chamber center (TCC). Initially it will be located in a reentrant well located 3.9 m from TCC. Data from GCD-3 will inform the design of a heavily-shielded “Super” GCD to be located as close as 20 cm from TCC. In conclusion, it will also provide a test-bed for faster optical detectors, potentially lowering the temporal resolution from the current ~100 ps state-of-the-art photomultiplier tubes (PMT) to ~10 ps Pulse Dilation PMT technology currently under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma ray measurements at OMEGA with the newest gas Cherenkov Detector “GCD-3”

Initial results from the newest Gas Cherenkov Detector (GCD-3) are reported demonstrating improved performance over previous GCD iterations. Increased shielding and lengthening of the Cherenkov photon optical path have resulted in a diminished precursor signal with increased temporal separation between the precursor and the primary DT Cherenkov signal. Design changes resulted in a measured GCD-3 sensitivity comparable to GCD-1 at identical 100 psia CO 2 operation. All metal gasket seals and pressure vessel certification to 400 psia operation allow for a GCD-3 lower Cherenkov threshold of 1.8 MeV using the fluorinated gas C 2 F 6 as compared to the 6.3 MeV lower limit of GCD-1 and GCD-2. Calibration data will be used to benchmark GEANT4 and ACCEPT detector models. Lastly, the GCD-3 acts as a prototype for the Super GCD being fielded at the National Ignition Facility (NIF) as part of the National Diagnostics Plan and will be installed at NIF in early 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experiments

A new Gas Cherenkov Detector (GCD) with low-energy threshold and high sensitivity, currently known as Super GCD (or GCD-3 at OMEGA), is being developed for use at the OMEGA Laser Facility and the National Ignition Facility (NIF). Super GCD is designed to be pressurized to ≤400 psi (absolute) and uses all metal seals to allow the use of fluorinated gases inside the target chamber. This will allow the gamma energy threshold to be run as low at 1.8 MeV with 400 psi (absolute) of C{sub 2}F{sub 6}, opening up a new portion of the gamma ray spectrum. Super GCD operating at 20 cm from TCC will be ∼400 × more efficient at detecting DT fusion gammas at 16.7 MeV than the Gamma Reaction History diagnostic at NIF (GRH-6m) when operated at their minimum thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ejecta Particle-Size Measurements in Vacuum and Helium Gas using Ultraviolet In-Line Fraunhofer Holography

An Ultraviolet (UV) in-line Fraunhofer holography diagnostic has been developed for making high-resolution spatial measurements of ejecta particles traveling at many mm/μsec. This report will discuss the development of the diagnostic including the high-powered laser system and high-resolution optical relay system. In addition, the system required to reconstruct the images from the hologram and the corresponding analysis of those images to extract particles will also be described. Finally, results from six high-explosive (HE), shock-driven Sn ejecta experiments will be presented. Particle size distributions will be shown that cover most of the ejecta velocities for experiments conducted in a vacuum, and helium gas environments. In addition, a modification has been made to the laser system that produces two laser pulses separated by 6.8 ns. This double-pulsed capability allows a superposition of two holograms to be acquired at two different times, thus allowing ejecta velocities to be measured directly. Results from this double pulsed experiment will be described.

36 MATERIALS SCIENCE↗

Ejecta Particle-Size Measurements in Vacuum and Helium Gas using Ultraviolet In-Line Fraunhofer Holography

An ultraviolet (UV) in-line Fraunhofer holography diagnostic has been developed for making high-resolution spatial measurements of ejecta particles traveling at many mm/μsec. This report will discuss the development of the diagnostic, including the high-powered laser system and high-resolution optical relay system. In addition, we will also describe the system required to reconstruct the images from the hologram and the corresponding analysis of those images to extract particles. Finally, we will present results from six high-explosive (HE), shock-driven Sn-ejecta experiments. Particle-size distributions will be shown that cover most of the ejecta velocities for experiments conducted in a vacuum, and helium gas environments. In addition, a modification has been made to the laser system that produces two laser pulses separated by 6.8 ns. This double-pulsed capability allows a superposition of two holograms to be acquired at two different times, thus allowing ejecta velocities to be measured directly. Results from this double-pulsed experiment will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

Telecentric Zoom Lens Designed for the Cygnus X-Ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm. All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure and can be used in either a vertical or horizontal orientation.

Cygnus, telecentric zoom lens↗