Calibration and Alignment of Large Zoom Lenses
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Malone, Robert M..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Revised manuscript (post peer-review) for submission to Optical Engineering.
Presentation at the "Multi-Probe Radiography IV: Detectors and Image Analysis" workshop, to be held at LANL, in the Rosen Auditorium. Host is Bob Reinovsky, LANL, 505-699-1127. LANL Point of Contact: Mariana Alvarado Alvarez, LANL, 505-665-7994.
Explore the source record for details and available documents.
Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and
This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (ΔT ∙ Δα) should be less than 189 ppm, where ΔT is the temperature excursion and Δα is the difference in glass coefficient of thermal expansion. If the product (ΔT ∙ Δα) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets.
This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (∆T ∙ ∆α) should be less than 189 ppm, where ∆T is the temperature excursion and ∆α is the difference in glass coefficient of thermal expansion. If the product (∆T ∙ ∆α) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Presentation to be presented during the first annual Prompt Radiation Detection and Imaging Workshop, hosted by the NNSS Dynamic Instruments Team, April 25–28, 2022, at NLV C-01 Auditorium and via Webex.
Explore the source record for details and available documents.
Material scientists have developed computational modeling to predict the dynamic response of materials undergoing stress, but there is still a need to make precision measurements of surfaces undergoing shock compression. Miniature photonic Doppler velocimetry (PDV) probes have been developed to measure the velocity distribution from a moving surface traveling tens of kilometers per second. These probes use hundreds of optical fibers imaged by optical relays onto different regions of this moving surface. While previous work examined large surface areas, we have now developed a PDV microscope that can interrogate 37 different spots within a field of view of <1 mm, with a standoff distance of 17 mm, to analyze the motion differences across grain boundaries of the material undergoing dynamic stress. Each PDV fiber interrogates a 10 μm spot size on the moving surface. A separate imaging system using a coherent bundle records the location of the PDV spots relative to the grain boundaries prior to the dynamic event. Designing the mounting structures for the lenses, fibers, and coherent bundle was a challenge. To minimize back reflections, the fibers are index matched onto the first relay lens, which is made of fused silica. The PDV fibers are aligned normal to the moving surface. The imaging probe views the surface at an 18° angle. The coherent bundle is tilted 11° to its optical relay. All components are assembled into a single probe head assembly. The coherent bundle is removed from the probe head to be used for the next dynamic event. Alignment issues will also be discussed.
Tomographic imaging of large objects from an x-ray source require a 240 mm square scintillator that is imaged onto a 90 mm square charge-coupled device (CCD) with <0.01% distortion. A large pellicle and internal folding mirror keep the optical elements and the CCD camera out of the x-ray beam path to minimize shielding requirements. Better imaging is needed for 2-D digital radiography and computer tomography (3-D) on the Los Alamos National Laboratory’s Microtron x-ray–generating source, a bremsstrahlung source with endpoint energies of 6, 10, 15, and 20 MeV. Large objects are placed into the x-ray beam and rotated between radiographs. X-rays are deposited into scintillators that are viewed with digital cameras. Better light gathering is needed because the scintillators emit low levels of light. Earlier imaging techniques used film in contact with the scintillator. Our design goal is to match the resolution of the digital camera system to that of the film. 3-D tomography requires extremely low distortion of the collected images.
Sn ejecta particle-size distributions from the break-up of a microsheet in a vacuum will be presented. The micro-sheet was created from a high explosive driven shock wave passing through a precision groove machined into a Sn sample. The particle-size measurements were carried out using an ultraviolet in-line Fraunhofer holography diagnostic. In conclusion, the diagnostic will be presented along with particle-size distributions over most of the ejecta velocities throughout the microsheet.
A probe including a multiple lens array is disclosed to measure velocity distribution of a moving surface along many lines of sight. Laser light, directed to the moving surface is reflected back from the surface and is Doppler shifted, collected into the array, and then directed to detection equipment through optic fibers. The received light is mixed with reference laser light and using photonic Doppler velocimetry, a continuous time record of the surface movement is obtained. An array of single-mode optical fibers provides an optic signal to the multiple lens array. Numerous fibers in a fiber array project numerous rays to establish many measurement points at numerous different locations. One or more lens groups may be replaced with imaging lenses so a stereo image of the moving surface can be recorded. Imaging a portion of the surface during initial travel can determine whether the surface is breaking up.
Presentation describes research into use of LightTools, an illumination design program, to optimize time and sensitivity performance in Liquid-VI gamma detectors for neutron-diagnosed experiments.
Presentation describes proposed 5x5 NSDE detector system designed to improve response times in gamma/neutron liquid detector array.