Search NASA⌕ Search

Engineering topics

Manard, Benjamin

Publications and source records attributed to Manard, Benjamin.

Electrothermal vaporization as a new method for pre-inspection check samples

The use of electrothermal vaporization (ETV) has not been readily applied to nuclear safeguards or pre inspection check (PIC) sample analysis, even though the technique is ideally suited for low level (pg) isotopic quantification due to its high analyte transport efficiency. Here demonstrate the ETV method for PIC safeguard analysis. The ETV system is an automated, commercial of the shelf (COTS) technology, with the capability to introduce solid samples to a mass spectrometer platform. The system has been shown to simultaneously determine uranium assay, and the major isotopic ratios for uranium and plutonium. The ETV unit has demonstrated analysis up to 50 samples a day autonomously. The utilization of this ETV methodology provide a secondary option to the current PIC analysis and offers high throughput, enhanced sensitivity, and broader isotopic detection platform.

Hexel, Cole↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO 2 (NO 3 ) 2 ·6H 2 O) and uranyl fluoride (UO 2 F 2 ) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO 2 F 2 , respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO 2 (NO 3 ) 2 ·6H 2 O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U, respectively. The % RD of the UO 2 F 2 isotope ratios were 1.9 and 0.60% for 234 U/ 238 U and 235 U/ 238 U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234 U, 235 U and 238 U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO 2 (NO 3 ) 2 ·6H 2 O and UO 2 F 2 particulates on cotton swipes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploration of ICP platforms for measuring elemental impurities in uranium ore concentrates

Presented here is a look at different inductively coupled plasma (ICP) platforms including sector field, triple quadrupole mass spectrometric configurations, and optical emission spectroscopy. The goal of this paper was to convey the feasibility of trace elemental analysis of a uranium ore concentrate with varying ICP-based platforms. It was predicted that low mass elements would be better determined through optical means, or the mass collision/reaction technology of the triple quadrupole mass spectrometer, in comparison to high resolution measurements of magnetic sector-based configurations. Ultimately, it is difficult to achieve an “optimal” analysis of 20+ elements, for numerous samples, on a single platform, especially when time, measurement reproducibility, sensitivity, and robustness should be considered. The work presented here highlights the advantages and disadvantages of the respective trace elemental analysis platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing 3D Morphological and Chemical Evolution Mechanisms of Metals in Molten Salt by Multimodal Microscopy

Growing interest in molten salts as effective high-temperature heat-transfer fluids for sustainable energy systems drives a critical need to fundamentally understand the interactions between metals and molten salts. This work utilizes the multimodal microscopy methods of synchrotron X-ray nanotomography and electron microscopy to investigate the 3D morphological and chemical evolution of two-model systems, pure nickel metal and Ni-20Cr binary alloy, in a representative molten salt (KCl-MgCl2 50–50 mol %, 800 °C). In both systems, unexpected shell-like structures formed because of the presence of more noble tungsten, suggesting a potential route of using Ni–W alloys for enhanced molten-salt corrosion resistance. The binary alloy Ni-20Cr developed a bicontinuous porous structure, reassembling functional porous metals manufactured by dealloying. This work elucidates better mechanistic understanding of corrosion in molten salts, which can contribute to the design of more reliable alloys for molten salt applications including next-generation nuclear and solar power plants and opens the possibility of using molten salts to fabricate functional porous materials.

36 MATERIALS SCIENCE↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗