Search NASA⌕ Search

Engineering topics

Manard, Benjamin Thomas

Publications and source records attributed to Manard, Benjamin Thomas.

An automated micro-separation system for the chromatographic removal of uranium matrix for trace element analysis by ICP-OES

An automated, miniaturized, off-line separation technique is presented here using an Elemental Scientific Inc. microFAST MC system with UTEVA resin to extract the uranium matrix from its trace element impurities in aqueous media. The collected fractions were analyzed for ~30 trace elements using inductively coupled plasma – optical emission spectroscopy. Ten replicate samples were processed with a single column resulting in precision ranging from 3.3% to 6.2% relative standard deviation with regards to the trace element recoveries. Accuracy, with respect to trace element concentrations in the U 3 O 8 Certified Reference Material 124-1, resulted in an average of 13.9% relative deviation while accuracy to the Canadian U3O8 reference material, CUP-2, resulted in an average relative deviation of 8.6%. In conclusion, the total separation time of this automated process was reduced to ~30 min per sample while employing a 0.5 mL UTEVA chromatographic resin bed and 2.5 mg of uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials

Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗