Search NASA⌕ Search

Engineering topics

Manney, G. L.

Publications and source records attributed to Manney, G. L..

At least 37 records · Page 2

Development of the polar vortex in the 1999-2000 Arctic winter stratosphere

The 1999-2000 Arctic stratospheric vortex was unusually cold, especially in the early winter lower stratosphere, with a larger area near polar stratospheric cloud formation temperatures in Dec and Jan, and much lower temperatures averaged over Nov-Jan, than any previously observed Arctic winter.

Ozone loss meteorology arctic stratospheric↗

Simulation of the December 1998 Stratospheric Major Warming

Prior to 1991, major warmings (defined by increasing zonal mean temperatures and zonal mean easterly winds from 60degN to the pole at 10 hPa) typically occurred approximately once every two Arctic winters; a major warming in mid-Dec. 1998 was the first since Feb. 1991. The Dec. 1998 warming was also the second earliest on record. The earliest, and the only other major warming on record before the end of Dec. was in early Dec 1987; prior to that, the earliest was in late Dec./early Jan. 1984-85. The 1984-85 and 1987 warmings resulted in the warmest and weakest lower stratospheric polar vortices in the 20 years before 1998-99. Fig. 1 compares temperatures and vortex strength in 1998-99 with those in the previous 20 years, using the US National Center for Environmental Prediction (NCEP) record; 1987-88 and 1984-85 are also highlighted. The Dec. 1998 warming had a more pronounced effect on mid-stratospheric temperatures than the Dec. 1987 warming (Fig. 1a), although smaller than that of warmings later in winter (e.g., 1984-85). 10-hPa temperatures fell well below average again in late Jan. 1999 and remained unusually low until an early final warming began in late Feb. 840 K PV gradients (Fig. 1c) set a record minimum in Jan. 1999, but were near average in Feb before the final warming. The effect of the Dec. 1998 warming on lower stratospheric temperatures was comparable to that of other major warmings; there was a brief period of record-high minimum 46-hPa temperatures in early Jan 1999 (Fig. 1b), and temperatures then fell to near average for a short period in mid-Feb. Lower stratospheric PV gradients were the weakest on record during the 1998-99 winter (Fig. 1d). The evolution of the vortex and minimum temperatures during 1998-99 was remarkably similar to that during 1987-88, the only previous year when a major warming was observed before the end of Dec.

Manney, G. L.↗

Correlations of Stratospheric Abundances of CH4 and N2O Derived from ATMOS Measurements

Atmospheric Trace MOlecule Spectroscopy (ATMOS) measurements made over a wide range of altitudes and latitudes demonstrate compact correlations between mixing ratios of CH, and N,O. Tight but distinct correlations are observed for the tropics, the springtime Arctic vortex, and the extra-tropics/extra-vortex regions, indicating dynamical isolation between these regions. Little variability is apparent in correlations between CH4 and N20 from measurements made in different years (1992, 1993, and 1994), seasons (March/April and November), and hemispheres.

Rinsland, C. P.↗

Analysis of record-breaking low ozone values during the 1997 winter over NDSC Station Lauder, New Zealand

During early August 1997, the ozone column density measured over Lauder was unusually low, with a minimum value of 222 Dobson Units (DU) at August 10. These observations are striking since in August, during the Austral winter, the ozone column density should be heading towards its yearly maximum; The August mean ozone column density measured over Lauder between 1987 and 1996 was 348(+/-28) DU, the lowest monthly average in these ten years was 255 DU. Regular altitude profile measurements of ozone, performed at Network for the Detection of Stratospheric Change (NDSC) station Lauder, make it possible to do a detailed, altitude-resolved, study of the low ozone observations. The measurements show ozone poor air in two altitude regions of the stratosphere: A 'high region', extending from the 600 K to the 1050 K isentrope (25 to 34 km), and a 'low region', below about 550 K (22 km). High resolution reverse trajectory maps of potential vorticity (PV) and ozone mixing ratio, based on the assumption of passive advection by the large-scale three-dimensional winds, show that in the 'high region' the ozone poor air was part of the polar vortex, which was centered off the pole and extended over Lauder for several days, while in the 'low region' the ozone poor air was mixed in from low latitudes. A rapid recovery of the ozone column density, by more than 110 DU within 24 hours, was observed when in the low region an ozone rich filament of the polar vortex moved over Lauder, while in the high region the (ozone poor) high part of the vortex moved away.

Brinksma, E. J.↗

MLS Observations of Arctic Ozone Loss in 1996-1997

The Microwave Limb Sounder (MLS) observed ozone (O3) loss in the Arctic vortex beginning in January 1997 at 585 K (approximately 25 hPa) and in February 1997 at 465 K (approximately 50 hPa). Minimum vortex-averaged O3 mixing ratios observed in 1997 were higher than those in 1996, which were the lowest ever recorded by MLS. The vertical extent of O3 loss and maximum local O3 decreases were larger, but the decrease filled the vortex less completely, in 1997 than in 1996. Unusually low high-latitude column O3 above 100 hPa in April 1997 resulted mainly from dynamical effects of the unusually persistent lower stratospheric vortex and winter-like temperature patterns. Column O3 above 100 hPa averaged in comparable regions of the vortex showed a stronger decreasing trend in 1996-97 than in 1995-96, consistent with the larger vertical extent and maximum local values of lower stratospheric O3 loss. Chemical O3 loss resulted in an approximately 10% observed decrease in column O3 between late January and early April 1997.

Manney, G. L.↗

Polar Vortex Conditions During The 1995-96 Arctic Winter: MLS ClO and HNO3

Microwave Limb Sounder (MLS) measurements of lower stratospheric ClO and HNO3 during the 1995-96 Arctic winter are presented. The 1995-96 Arctic winter was both colder and more persistently cold than usual, leading to an enhancement in lower stratospheric ClO of greater magnitude, vertical extent, and duration than previously observed in the Arctic. Vortex concentrations of HNO3 in mid-December were large due to diabatic descent. Trajectory calculations indicate that localized severe depletions of gas-phase HNO3 in mid-February and early March did not arise from entrainment of midlatitude air into the vortex and were therefore probably related to polar stratospheric cloud (PSC) formation. A strong correlation between temperature and gas-phase HNO3 was evident, consistent with recurring PSC condensation and evaporation cycles.

Santee, M. L.↗

Polar Vortex Conditions during the 1995-96 Artic Winter: Meteorology and MLS Ozone

The 1995-96 northern hemisphere (NH) 205 winter stratosphere was colder than in any of the previous 17 winters, with lower stratospheric temperatures continuously below the type 1 (primarily HN03) polar stratospheric cloud (PSC) threshold for over 2 1/2 months. Upper tropospheric ridges in late Feb and early Mar 1996 led to the lowest observed NH lower stratospheric temperatures, and the latest observed NH temperatures below the type 2 (water ice) PSC threshold. Consistent with the unusual cold and chemical processing on PSCS, Upper Atmosphere Research Satellite (UARS) MLS observed a greater decrease in lower stratospheric ozone (03) in 1995-96 than in any of the previous 4 NH winters. 03 decreased throughout the vortex over an altitude range nearly as large as that typical of the southern hemisphere (SH). The decrease between late Dec 1995 and early Mar 1996 was about 2/3 of that over the equivalent SH period. As in other NH winters, temperatures in 1996 rose above the PSC threshold before the spring equinox, ending chemical processing in the NH vortex much earlier than is usual in the SH. A downward trend in column 03 above 100 hPa during Jan and Feb 1996 appears to be related to the lower stratospheric 03 depletion.

Manney, G. L.↗

Chlorine Deactivation in the Lower Stratospheric Polar Regions during late Winter: Results from UARS

Recovery from enhanced chlorine conditions in the lower stratospheric polar regions of both hemispheres is investigated using data from the Upper Atmosphere Research Satellite (UARS). Microwave Limb Sounder (MLS) measurements of ClO within the polar vortices are used to infer ClO(sub x) (ClO + 2Cl202) abundances that are then correlated with simultaneous Cryogenic Limb Array Etalon Spectrometer (CLAES) measurements of ClON02 and Halogen Occultation Experiment (HALOE) measurements of HCl obtained starting within 5 days of the end of the MLS and CLAES high-latitude observing periods in each hemisphere. Time series of vortex-averaged mixing ratios are calculated on two potential temperature surfaces (585 K and 465 K) in the lower stratosphere for approximately month-long intervals during late winter: August 17 - September 17, 1992, in the southern hemisphere and February 12 - March 16, 1993, in the northern hemisphere. The observed mixing ratios are adjusted for the effects of vertical transport using diabatic vertical velocities estimated from CLAES tracer data. In the northern hemisphere, the decrease in ClO, is balanced on both surfaces by an increase in ClON02- In the southern hemisphere, continuing polar stratospheric cloud activity prevents ClO from undergoing sustained decline until about September 3. In contrast to the northern hemisphere, there is no significant chemical change in vortex-averaged ClON02 at 465 K, and there is an apparent decrease in ClON02 at 585 K, even after the enhanced ClO abundances have started to recede. Results from the SLIMCAT chemical transport model initialized with UARS data and run with OH + ClO yields HCl + 02 as an 8% channel suggest that the primary recovery product in the south during this time period is not ClON02, but HCl. HALOE HCl mixing ratios are extrapolated back to the time of the MLS and CLAES data. At 585 K, the chlorine budget can be made to balance by extrapolating HCl back to a value of 0.6 parts per billion by volume (ppbv) at the beginning of the study period; at 465 K, the contribution from extrapolated HCl is not sufficient to offset the loss in ClOx, and there is a slight imbalance between the decrease in reactive chlorine and the change in chlorine reservoirs. The difficulty in closing the chlorine budget in the southern hemisphere may arise from complications caused by ongoing activation, incomplete photochemical assumptions, and/or inadequate data quality.

Santee, M. L.↗

Seasonal Variations of Water Vapor in the Lower Stratosphere Inferred from ATMOS/ATLAS-3 Measurements of H2O and CH4

Stratospheric measurements of H2O and CH4 by the Atmospheric Trace Molecule Spectroscopy (ATMOS) Fourier transform spectrometer on the ATLAS-3 shuttle flight in November 1994 have been examined to investigate the altitude and geographic variability of H2O and the quantity H = (H2O + 2CH4) in the tropics and at mid-latitudes (8 to 49 deg N) in the northern hemisphere. The measurements indicate an average value of 7.24 +/- 0.44 ppmv for H between altitudes of about 18 to 35 km, corresponding to an annual average water vapor mixing ratio of 3.85 +/- 0.29 ppmv entering the stratosphere. The H2O vertical distribution in the tropics exhibits a wave-like structure in the 16- to 25-km altitude range, suggestive of seasonal variations in the water vapor transported from the troposphere to the stratosphere. The hygropause appears to be nearly coincident with the tropopause at the time of observations. This is consistent with the phase of the seasonal cycle of H2O in the lower stratosphere, since the ATMOS observations were made in November when the H2O content of air injected into the stratosphere from the troposphere is decreasing from its seasonal peak in July-August.

Abbas, M. M.↗

Trace Gas Transport in the Arctic Vortex Inferred from ATMOS ATLAS-2 Observations During April 1993

Measurements of the long-lived tracers CH4, N2O, and HF from the Atmospheric Trace Molecule Spectroscopy (ATMOS) instrument during the Atmospheric Laboratory for Science and Applications-2 (ATLAS-2) Space Shuttle mission in April 1993 are used to infer average winter descent rates ranging from 0.8 km/month at 20 km to 3.2 km/month at 40 km in the Arctic polar vortex during the 1992-93 winter. Descent rates in the mid-stratosphere are similar to those deduced for the Antarctic vortex using ATMOS/ATLAS-3 measurements in November 1994, but the shorter time period of descent in the Arctic leads to smaller total distances of descent. Strong horizontal gradients observed along the vortex edge indicate that the Arctic vortex remains a significant barrier to transport at least until mid-April in the lower to middle stratosphere.

Abrams, M. C.↗