Search NASA⌕ Search

Engineering topics

Mannion, Danielle R.

Publications and source records attributed to Mannion, Danielle R..

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical Assessment of Impurities Found in Process Gases using the InfiTOF, a High Resolution, Low Mass, Variable Time-of-Flight Mass Spectrometer

The JEOL InfiToF is a high-resolution, low mass (HRLM) mass spectrometer (MS) with the application potential to meet analytical needs for tritium handling systems, such as those at the Savannah River Tritium Facilities (SRTE) and those used in fusion research. The Service Level Agreement (SLA) #144 line 27 “InfiTOF R&D” has concluded its first year of efforts under Tritium Recycle and Renewal. The project goals for FY22 were: (1) Production of a finalized modification list for tritium hardened components in the InfiTOF, (2) perform an assessment on impurity gases commonly found in process gases from Tritium Facilities and (3) begin developing a set of standardized work instructions that will be used as a basis for operations on the InfiTOF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

LDRD External Report Summary

Matrix-Assisted Ionization is a new and highly promising mass spectrometry technique for rapid analysis of uranium; however, the chemistry and physics underlying this ionization mechanism are largely unknown. This effort seeks to understand the fundamental ionization phenomena by characterizing both ionization matrix materials themselves and analyte chemistry ionization trends.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗