Search NASA⌕ Search

Engineering topics

Mannion, Joseph M.

Publications and source records attributed to Mannion, Joseph M..

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method of making a carbon filament for thermal ionization

A method for modifying a carbon thermal ionization filament is disclosed. In particular, the method requires a step of reacting a fluorine-containing compound with the carbon thermal ionization filament to provide a fluorinated carbon thermal ionization filament. Such method can result in a fluorinated carbon thermal ionization filament that can be employed in a system, such as a thermal ionization mass spectrometer, for ionizing a sample.

Mannion, Joseph M.↗

Comprehensive Chemical Fingerprinting by Multidimensional GC and Supervised Machine Learning

This project leveraged advances in machine learning based data analysis techniques and untargeted analytical methods for organic analysis to progress nuclear nonproliferation technologies beyond current capabilities. The developed approaches can be used to detect and identify complex chemical fingerprints of facilities of interest. These techniques have been developed for fields such as metabolomics and genomics but have not been applied to nuclear nonproliferation applications. Adaptation of these techniques for volatile organic compound analysis has far reaching application within the scientific community including environmental chemistry, atmospheric physics, and climate sciences.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive Chemical Fingerprinting by Multidimensional GC and Supervised Machine Learning

This project leverages advances in machine learning based data analysis techniques and untargeted omic analytical methods to progress nuclear nonproliferation technologies beyond current capabilities. The developed approaches can be used to identify and detect complex chemical fingerprints of facilities of interest. These techniques have been developed for fields such as metabolomics and genomics but have not been applied to nuclear nonproliferation applications. Adaptation of these techniques for volatile organic compound analysis has far reaching application within the scientific community including environmental chemistry, atmospheric physics, and climate sciences.

97 MATHEMATICS AND COMPUTING↗

Rapid paper spray mass spectrometry characterization of uranium and exemplar molecular species

The ability to detect and quantify the presence of specific inorganic elements and complexes is essential for environmental monitoring and nuclear safeguards applications. In this work, paper spray ionization mass spectrometry (PSI–MS) was used for the rapid chemical and isotopic characterization of trace inorganic species collected on cotton swipe substrates. Here, the direct analysis of cotton swipes using this ambient ionization technique led to fast sample analysis that retained original chemical information of the source material with minimal sample preparation. Mass spectra were collected on an atmospheric pressure ionization, high–resolution mass spectrometer for solutions containing uranyl acetate, uranyl chloride, uranyl nitrate, and uranyl tri– n –butylphosphate (uranyl–TBP) complexes. Gadolinium nitrate was used as an internal standard for the quantitative analysis of uranium. To demonstrate the ability to characterize inorganic contaminants in the presence of uranium, a multi–element inorganic standard containing U, Bi, Pb, Cd, Fe, and Zn was deposited onto cotton substrates and directly analyzed without purification. All elements doped on the cotton substrate were detected with strong signal–to–noise (S/N) ratios (S/N~1000 for UO 2 + on multi–element doped swipes) and high integrated intensities (>10 5 counts) from collection periods of approximately 1 min. Limits of detection were determined to be approximately 94 ng for UO 2 + and uranyl acetate through the measurement of ppb level solutions. The rapid analysis of uranium and other inorganic–containing samples while still retaining original chemical information (e.g. uranyl complexation) was demonstrated. Qualitative detection and speciation were achieved in less than 1 min of analysis. For uranium isotopic quantitation, longer accumulations (>15 min) can be sustained to improve the accuracy of minor 235 U isotopic abundance measurements to approximately 1% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗