Search NASA⌕ Search

Engineering topics

Mantenieks, M. A.

Publications and source records attributed to Mantenieks, M. A..

32 records · Page 2

Status of 30-centimeter-diameter mercury ion thruster isolator development

Results are presented of several 30 cm diameter mercury ion thruster isolator life tests that show that the onset and exponential increase of leakage current problems observed in earlier thruster operations and isolator tests have been solved. A 10,006 hour life test of a main isolator vaporizer operated with no mercury flow at 320 C and 1500 volts was found to have no onset of leakage current during the test. A cathode-isolator vaporizer operated with a mercury discharge at 340 to 360 C and 1200 volts for 18,000 hours, was found to have a small increase of leakage current with time. A 10,000 hour thruster life test exhibited no increase of leakage current during the life test. Isolators have been developed which will satisfy 30 cm mercury ion thruster mission requirements.

Mantenieks, M. A.↗

Sputtering phenomena of discharge chamber components in a 30-cm diameter Hg ion thruster

Sputtering and deposition rates were measured for discharge chamber components of a 30-cm diameter mercury ion thruster. It was found that sputtering rates of the screen grid and cathode baffle were strongly affected by geometry of the baffle holder. Sputtering rates of the baffle and screen grid were reduced to 80 and 125 A/hr, respectively, by combination of appropriate geometry and materials selections. Sputtering rates such as these are commensurate with thruster lifetimes of 15,000 hours or more. A semiempirical sputtering model showed good agreement with the measured values.

Mantenieks, M. A.↗

Dynamic characteristics of a 30-centimeter mercury ion thruster

The present work reports on measurements of the fluctuations in the beam current, discharge current, neutralizer keeper current, and discharge voltage of a 30-cm ion thruster made with 60Hz laboratory-type power supplies. The intensities of the fluctuations (ratio of the root-mean-square magnitude to time-average quantity) were found to depend significantly on the beam and magnetic baffle currents. The shape of the frequency spectra of the discharge plasma fluctuations was related to the beam and magnetic baffle currents. The predominant peaks of the beam and discharge current spectra occurred at frequencies less than 30 kilohertz. This discharge chamber resonance could be attributable to ion-acoustic wave phenomena. Cross-correlations of the discharge and beam currents indicated that the dependence on the magnetic baffle current was strong. The measurements revealed that the discharge current fluctuations directly contribute to the beam current fluctuations and that the power supply characteristics can modify these fluctuations.

Serafini, J. S.↗

Studies of internal sputtering in a 30-cm ion thruster

Initial studies have been made of the sputtering and deposition phenomena in a 30-cm thruster. Sputtering rates, of the cathode baffle, one of the main sources of sputtered material in a thruster, have beem measured by weight loss as a function of several thruster parameters. Sputtering rates were found to increase with both cathode flow rate and beam current when constant discharge voltage of 37 volts and power losses of 185 ev/ion were maintained. Sputtering rates were reduced 24% as discharge voltage was decreased from 37 to 33 volts while keeping discharge power constant. Qualitative agreement was found between sputtering rates obtained by the weight loss and those implied by spectroscopically observed line intensities of the excited iron sputtered atoms. After the completion of the sputtering tests, deposition and sputtering sites inside the thruster were identified.

Mantenieks, M. A.↗

A multiple thruster array for 30-cm thrusters

The 3.0-m diameter chamber of the 7.6-m diameter by 21.4-m long vacuum tank at NASA LeRC was modified to permit testing of an array of up to six 30-cm thrusters with a variety of laboratory and thermal vacuum bread-board power systems. A primary objective of the Multiple Thruster Array (MTA) program is to assess the impact of multiple thruster operation on individual thruster and power processor requirements. The areas of thruster startup, steady-state operation, throttling, high voltage recycle, thrust vectoring, and shutdown are of special concern. The results of initial tests are reported.

Rawlin, V. K.↗

Studies of internal sputtering in a 30-cm ion thruster

Initial studies have been made of the sputtering and deposition phenomena in a 30-cm thruster. Sputtering rates, of the cathode baffle, one of the main sources of sputtered material in a thruster, have been measured by weight loss as a function of several thruster parameters. Sputtering rates were found to increase with both cathode flow rate and beam current when constant discharge voltage of 37 volts and power loses of 185 ev/ion were maintained. Sputtering rates were reduced 24% as discharge voltage was decreased from 37 to 33 volts while keeping discharge power constant. Qualitative agreement was found between sputtering rates obtained by the weight loss and those implied by spectroscopically observed line intensities of the excited iron sputtered atoms. After the completion of the sputtering tests, deposition and sputtering sites inside the thruster were identified.

Mantenieks, M. A.↗

Dynamic characteristic of a 30-cm mercury ion thruster

Measurements of the fluctuations of the discharge and beam plasmas of a 30 centimeter ion thruster were performed using 60 Hertz laboratory type power supplies. The time-varying properties of the discharge voltage and current, the ion beam current, and neutralizer keeper current were measured. The intensities of the fluctuations were found to depend on the beam and magnetic baffle currents. The shape of the frequency spectra of the discharge plasma fluctuations was found to be related to the beam and magnetic baffle currents. The measurements indicated that the discharge current fluctuations directly contribute to the beam current fluctuations and that the power supply characteristics modify these fluctuations.

Serafini, J. S.↗

Investigation of mercury thruster isolators

Mercury ion thruster isolator lifetime tests were performed using different isolator materials and geometries. Tests were performed with and without the flow of mercury through the isolators in an oil diffusion pumped vacuum facility and cryogenically pumped bell jar. The onset of leakage current in isolators tested occurred in time intervals ranging from a few hours to many hundreds of hours. In all cases, surface contamination was responsible for the onset of leakage current and subsequent isolator failure. Rate of increase of leakage current and the leakage current level increased approximately exponentially with isolator temperature. Careful attention to shielding techniques and the elimination of sources of metal oxides appear to have eliminated isolator failures as a thruster life limiting mechanism.

Mantenieks, M. A.↗

Investigation of mercury thruster isolators

Mercury ion thruster isolator lifetime tests were performed using different isolator materials and geometries. Tests were performed with and without the flow of mercury through the isolators in an oil diffusion pumped vacuum facility and cryogenically pumped bell jar. The onset of leakage current in isolators occurred in time intervals ranging from a few hours to many hundreds of hours. In all cases, surface contamination was responsible for the onset of leakage current and subsequent isolator failure. Rate of increase of leakage current and the leakage current level increased approximately exponentially with isolator temperature. Careful attention to shielding techniques and the elimination of sources of metal oxides appear to have eliminated isolator failures as a thruster life limiting mechanism.

Mantenieks, M. A.↗