Search NASA⌕ Search

Engineering topics

Manukian, Ara

Publications and source records attributed to Manukian, Ara.

Plant health sensing

If plants are to be used as a food source for long term space missions, they must be grown in a stable environment where the health of the crops is continuously monitored. The sensor(s) to be used should detect any diseases or health problems before irreversible damage occurs. The method of analysis must be nondestructive and provide instantaneous information on the condition of the crop. In addition, the sensor(s) must be able to function in microgravity. This first semester, the plant health and disease sensing group concentrated on researching and consulting experts in many fields in attempts to find reliable plant health indicators. Once several indicators were found, technologies that could detect them were investigated. Eventually the three methods chosen to be implemented next semester were stimulus response monitoring, video image processing and chlorophyll level detection. Most of the other technologies investigated this semester are discussed here. They were rejected for various reasons but are included in the report because NASA may wish to consider pursuing them in the future.

Manukian, Ara↗

Non-destructive plant health sensing using absorption spectroscopy

The sensor group of the 1988 EGM 4001 class, working on NASA's Controlled Ecological Life Support Systems (CELSS) project, investigated many different plant health indicators and the technologies used to test them. The project selected by the group was to measure chlorophyll levels using absorption spectroscopy. The spectrometer measures the amount of chlorophyll in a leaf by measuring the intensity of light of a specific wavelength that is passed through a leaf. The three wavelengths of light being used corresponded to the near-IR absorption peaks of chlorophyll a, chlorophyll b, and chlorophyll-free structures. Experimentation showed that the sensor is indeed measuring levels of chlorophyll a and b and their changes before the human eye can see any changes. The detector clamp causes little damage to the leaf and will give fairly accurate readings on similar locations on a leaf, freeing the clamp from having to remain on the same spot of a leaf for all measurements. External light affects the readings only slightly so that measurements may be taken in light or dark environments. Future designs and experimentation will concentrate on reducing the size of the sensor and adapting it to a wider range of plants.

Bledsoe, Jim↗