Search NASA⌕ Search

Engineering topics

Manukyan, Khachatur

Publications and source records attributed to Manukyan, Khachatur.

Cross-sections for 43 Sc, 44 m Sc, and 44 g Sc from two heavy ion reactions

Two different heavy ion reactions were used to produce 43 Sc (t$_{\frac12}$ = 3.891 h), 44g Sc (t$_{\frac12}$ = 4.042 h), and 44m Sc (t$_{\frac12}$ = 58.61 h) among other stable or long-lived chemically separable products. Production cross sections for 19 F + 27 Al and the reverse kinematic reaction 35 Cl + nat B were measured using an MC-SNICS ion source and the Notre Dame FN Tandem Accelerator. 19 F beams from 35 to 60 MeV were produced with beam currents between 40–80 pnA and 35 Cl beams were produced at six entrance energies with comparable beam currents. This work reports nuclear reaction cross sections 27 Al ( 19 F, x) 43 Sc, 27 Al ( 19 F, pn) 44g Sc, and 27 Al ( 19 F, pn) 44m Sc at six energies between 35 and 60 MeV lab energy. Cross sections within the same energy range were measured for 27 Al ( 19 F, 3pn) 42 K and 27 Al ( 19 F, 3p) 43 K. Comparative measurements were performed for the same compound nucleus produced from nat B( 35 Cl, x) 43 Sc, nat B( 35 Cl, pn) 44g Sc, and nat B( 35 Cl, pn) 44m Sc. The measured thin target cross sections show an overestimation by several statistical models for the scandium radioisotopes. This is corroborated by the measured thick target production rates for both entrance channels. This may be due to angular momentum effects of a heavy ion entrance channel compared to light-ion production, but additional work is required to understand this discrepancy. Finally, these measurements demonstrate that the medically useful 43 Sc, 44g Sc, and 44m Sc radioisotopes can be free of the long-lived contaminant 46 Sc without the use of enriched targets, using heavy ion beams and robust target materials.

07 ISOTOPE AND RADIATION SOURCES↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-pressure phase transition in 3-D printed nanolamellar high-entropy alloy by imaging and simulation insights

Abstract We report on the high-resolution imaging and molecular dynamics simulations of a 3D-printed eutectic high-entropy alloy (EHEA) Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2 consisting of nanolamellar BCC and FCC phases. The direct lattice imaging of 3D-printed samples shows the Kurdjumov–Sachs (K–S) orientation relation {111} FCC parallel to {110} BCC planes in the dual-phase lamellae. Unlike traditional iron and steels, this alloy shows an irreversible BCC-to-FCC phase transformation under high pressures. The nanolamellar morphology is maintained after pressure cycling to 30 GPa, and nano-diffraction studies show both layers to be in the FCC phase. The chemical compositions of the dual-phase lamellae after pressure recovery remain unchanged, suggesting a diffusion-less BCC–FCC transformation in this EHEA. The lattice imaging of the pressure-recovered sample does not show any specific orientation relation between the two resulting FCC phases, indicating that many grain orientations are produced during the BCC–FCC phase transformation. Molecular dynamics simulations on phase transformation in a nanolamellar BCC/FCC in K–S orientation show that phase transformation from BCC to FCC is completed under high pressures, and the FCC phase is retained on decompression aided by the stable interfaces. Our work elucidates the irreversible phase transformation under static compression, providing an understanding of the orientation relationships in 3-D printed EHEA under high pressures.

3-D Printing↗