Search NASA⌕ Search

Engineering topics

Marashdeh, Qussai M.

Publications and source records attributed to Marashdeh, Qussai M..

Propellant Mass Gauging in a Spherical Tank under Micro-Gravity Conditions Using Capacitance Plate Arrays and Machine Learning

Propellant mass gauging under micro-gravity conditions is a challenging task due to the unpredictable position and shape of the fuel body inside the tank. Micro-gravity conditions are common for orbiting satellites and rockets that operate on limited fuel supplies. Capacitance sensors have been investigated for this task in recent years; however, the effect of various positions and shapes of the fuel body is not analyzed in detail. In this paper, we investigate this with various fill types, such as annular, core-annular, and stratified fills at different positions. We compare the performance among several curve-fitting-based approaches and a machine-learning-based approach, the latter of which offers superior performance in estimating the fuel content.

47 OTHER INSTRUMENTATION↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗

Flow Loop Study of ECT-Based Volume Fraction Monitoring in Oil–Water Two-Phase Flows

Measurement of phase volume fractions in water-containing multiphase flows is necessary for the optimization of a host of industrial flow processes. Many water-containing multiphase flows can be classified as either water-dispersed or water-continuous mixtures. A recently developed approach based on Hanai’s mixture formula and utilizing electrical capacitance tomography (ECT) sensors have shown good potential for obtaining water volume fraction estimates in two-phase water-containing flows with different water salinity levels. However, the proposed approach was investigated via controlled experiments restricted to static configurations while, in practice, multiphase flows can be dynamic and unpredictable. In this work, we perform a flow loop study of the proposed ECT-based method for volume fraction estimation in oil–water two-phase flows. Here, we evaluate the performance of the proposed method in both water-dispersed and water-continuous flow regimes by employing different types of capacitive sensors in cylindrical arrangements and parallel-plate rectangular arrangements.

02 PETROLEUM↗

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

Relevance Vector Machine Image Reconstruction Algorithm for Electrical Capacitance Tomography With Explicit Uncertainty Estimates

We present a Relevance Vector Machine (RVM) based algorithm for electrical capacitance tomography (ECT) applications that can concurrently provide image reconstruction results and uncertainty estimates about the reconstruction. To illustrate the RVM operation in ECT, we simulate typical ECT scenarios, making explicit the connection between the reconstructed pixel values and the corresponding uncertainty estimates in each case. We compare the RVM reconstruction performance with that of the Iterative Landweber Method (ILM) and the least absolute shrinkage and selection operator (LASSO) in all the considered scenarios. The results show that, in addition to the key advantage of providing uncertainty measures, RVM can achieve similar reconstruction results with either lower or similar computational complexity.

42 ENGINEERING↗

Inverse Normalization Method for Cross-Sectional Imaging and Velocimetry of Two-Phase Flows Based on Electrical Capacitance Tomography

Proper normalization of the measured capacitance data is a prerequisite in electrical capacitance tomography (ECT). Conventional methods, such as parallel and series normalization, assume a higher permittivity perturbation in a homogeneous (lower) permittivity background. Although this is applicable to a number of cases, some two-phase flows are better modeled instead as a lower permittivity perturbation in a homogeneous (higher) permittivity background. A different normalization method is proposed for such cases, which provides similar image quality as conventional, but is particularly beneficial for velocimetry applications based on sensitivity gradient of ECT sensor. Furthermore, simulation and experimental results are provided to illustrate the advantages for the proposed normalization technique.

47 OTHER INSTRUMENTATION↗

Velocity Profiling of Multiphase Flows Using Capacitive Sensor Sensitivity Gradient

Velocity profiling of a flow involves the task of determining the velocity vector at every point in a given flow volume. A new method is proposed for velocity profiling of multiphase flows based on electrical capacitance volume tomography (ECVT) sensors. The proposed method utilizes a mapping between the change in measured capacitances and the displacement of flow that is effected by the spatial gradient of the sensitivity distribution. Here, this novel mapping not only avoids the need for costly image cross-correlations but also is fully compatible with existing ECVT sensor and image reconstruction algorithms. Simulation and measurement results are provided to demonstrate the proposed method.

47 OTHER INSTRUMENTATION↗

Electrical Capacitance Volume Tomography: A Comparison between 12- and 24-Channels Sensor Systems

Spatial resolution represents akey performance aspect in electrical capacitance volume tomography (ECVT). Factors affecting the resolution include the ``soft-field'' nature of ECVT, the number of capacitance channels used, the ill-conditioned nature of the imaging reconstruction problem, and the signal-to-noise ratio of the measurement apparatus. In this study, the effect of choosing different numbers of capacitance plates on the performance of ECVT is investigated. Specifically, two ECVT sensors with 12 and 24 capacitance channels but covering equal volumes of a cylinder are used to examine the resulting impact on the image resolution.

20 FOSSIL-FUELED POWER PLANTS↗