Search NASA⌕ Search

Engineering topics

Marcus, R. Kenneth

Publications and source records attributed to Marcus, R. Kenneth.

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Coupling of the Liquid Sampling–Atmospheric Pressure Glow Discharge to Orbitrap Mass Analyzers for Uranium Isotope Ratio Analysis: Evolution of the Methodology and Implications to the Field

Just over a decade ago, a truly outside-of-the-box approach to isotope ratio mass spectrometry (IRMS) was undertaken between research groups at Clemson University and the Pacific Northwest National Laboratory. The original motivation dealt with projections as to whether or not microplasmas could be developed into practical elemental ionization sources, perhaps for transportable analysis applications. In particular, the use of the liquid sampling–atmospheric pressure glow discharge (LS-APGD) was pursued. Its interfacing to an ultra-high resolution Orbitrap platform, proved not only facile, but opened up a wealth of potential applications. Here, we lay out a historical, tutorial description of the interfacing and the evolution of the methodology regarding IRMS of uranium. Practical challenges and opportunities are described, which hopefully provide guidance to further applications in high resolution IRMS. It is hoped that, while detailed and lengthy, the didactic nature of the presentation provides experimental insights and tips, and also serves as an homage to our very good friend, Professor Gary M. Hieftje, whose scientific inspiration and comradery have been immeasurably important in our own careers.

Koppenaal, David W.↗

Multi-electrode/multi-modal atmospheric pressure glow discharge plasma ionization device

Apparatus include an atmospheric pressure glow discharge (APGD) analyte electrode defining an analyte discharge axis into an APGD volume, and a plurality of APGD counter electrodes having respective electrical discharge ends directed to the APGD volume, wherein the APGD analyte electrode and the APGD counter electrodes are configured to produce an APGD plasma in the APGD volume with a voltage difference between the APGD analyte electrode and one or more of the AGPD counter electrodes. An electrode can be integrated into an ion inlet. Apparatus can be configured to perform auto-ignition and/or provide multi-modal operation through selectively powering electrodes. Electrode holder devices are disclosed. Related methods are disclosed.

Koppenaal, David W.↗

Improved uranium isotopic ratio determinations for the liquid sampling-atmospheric pressure glow discharge orbitrap mass spectrometer by use of moving average processing

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) is a versatile combined atomic and molecular (CAM) ionization source capable of ionizing elemental species, small polar compounds, low-polarity polycyclic aromatic hydrocarbons, and proteins. While the LS-APGD has been proven capable of determining the 235U/238U isotope ratio in enriched and natural uranium, recent efforts have strived to reduce the analysis time of individual measurements by employing higher-order data processing techniques, specifically, moving average methods. Additionally, the use of a moving average (of data windows of various widths) improves the precision of the ratio measurements and reduces the number of scans needed to be collected to generate high-precision results. Additionally, use of the moving average minimizes the quantity of sample that needs to be analyzed while reducing the measurement time. These reductions have allowed isotope ratio (IR) determinations to be made using injections instead of direct infusion of the analyte. For example, employing a 40-point window width in the moving average to direct infusion data reduced the percent relative standard deviation (% RSD) of the 235U/238U values from 3.4% to 0.5%. For the injection of a 100 μL aliquot, the % RSD was reduced from 5.3% to 0.7%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗