Search NASA⌕ Search

Engineering topics

Mariano Mercado

Publications and source records attributed to Mariano Mercado.

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly flow boiling in the heating configuration is relevant to the propellant transfer process both in microgravity and on other planetary surfaces. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper demonstrates how these correlations have been ported into Thermal Desktop to improve predictive performance. To test the validity of the new correlations, Thermal Desktop is validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid.

cryogenic propellant transfer↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

Progress on the Reduced Gravity Cryogenic Transfer (RGCT) Project

Reduced gravity transfer of cryogenic propellants is crucial to being able to perform planned extended-duration space exploration missions. However, the transfer of cryogenic propellants under reduced gravity conditions has never been demonstrated in a mass-efficient fashion. Efficient cryogenic fluid transfer methods will reduce the transfer time or amount of propellant consumed for chilldown of transfer lines and tanks and ensure successful engine restart or fill of a customer receiver tank. The purpose of the Reduced Gravity Cryogenic Transfer (RGCT) project is to enhance line chilldown, tank chilldown, and tank fill/transfer in a reduced gravity environment through (1) ground and reduced gravity cryogenic testing and (2) numerical model development and validation, which includes empirical, lumped capacitance, and computational fluid dynamics modeling. Technologies developed, data gathered, and models developed and validated under RGCT have played a critical role in enabling longer duration in-space missions. This presentation will provide a description of the ongoing cryogenic propellant transfer ground and reduced gravity testing, numerical modeling, and technology development to-date.

Boiling↗

Parametric Analysis of the Charge-Hold-Vent Method for Cryogenic Propellant Tank Chill Down

Abstract. In the absence of external heat exchangers, the on-orbit transfer of cryogenic propellants requires the receiver tank to first be quenched to a sufficiently low energy state to allow for a continuous no-vent fill to avoid unnecessary venting of liquid. One proposed method for tank chilldown that minimizes the potential for venting liquid is the charge hold vent (CHV) method. CHV follows a cyclic process that gradually removes thermal energy from the receiver tank by injecting liquid with the vent valve closed and allowing the fluid and wall to reach near-thermal equilibrium before venting the superheated vapor. However, the CHV method must be optimized to minimize complexity, mass, and time. This paper presents a modular CHV analytical model used to quantify the number of cycles and propellant mass consumed based on first principles. The model is used to examine the effect of eight parameters: receiver tank material, volume, mass, maximum expected operating pressure, and initial pressure, liquid injection pressure and temperature, and the target temperature. The model is validated against the only two available CHV datasets. Based on results, the tank mass-to-volume ratio is the most important factor in determining the number of CHV cycles and thus degree of difficulty in tank chilldown. The model can easily be used for early-stage design, sizing, and analysis of cryogenic propellant transfer systems. Keywords: tank chilldown, charge-hold-vent, no-vent fill

Tank Chilldown↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Helium

Understanding two-phase cryogenic propellant behavior is key to enabling technologies for future spaceflight missions. Developing accurate models of two-phase flow phenomena, particularly in the current work, flow boiling in the heating configuration, is relevant to the propellant transfer process both in 1-g and microgravity. Currently there is a need for more accurate, direct cryogenic data anchored models for various boiling phenomena. Recently, universal correlations for cryogens flowing in heated tubes have been developed for a wide variety of fluids, thermodynamic conditions, and various regimes across the boiling curve, and have been patched to provide a smooth, continuous predictive curve. This paper describes implementation and validation of these correlations into Thermal Desktop to improve predictive performance, with a focus on liquid helium. Results from Thermal Desktop using both the built-in and new correlations are validated against a historical dataset of flow boiling experiments in the heating configuration using liquid helium. Based on results, the new correlations show a substantial improvement over the original built-in flow boiling correlations in Thermal Desktop in predicting the wall temperature as a function of preponderant parameters for this quantum fluid at temperatures greater than the lambda temperature, T λ = 2.17K.

cryogenic propellant transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Methane and Liquid Nitrogen

Future in-space cryogenic architectures will depend on the ability to accurately model various stages of cryogenic propellant transfer and storage. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling phenomena. This paper presents the implementation and validation of recently developed universal cryogenic flow boiling correlations for saturated flow boiling heat transfer coefficients (HTC) and critical heat flux (CHF) into the Thermal Desktop (SINDA/FLUINT) modeling software. The correlations are validated against steady state cryogenic flow boiling historical heated tube cases from liquid nitrogen and liquid methane experiments covering a wide range of inlet conditions, mass flux, and heat flux. Overall, Thermal Desktop with the new universal cryogenic flow boiling correlations demonstrates significant improvement in predictive performance for both wall temperature and CHF location compared to the Thermal Desktop model with built-in correlations when both are compared to the data.

Mariano Mercado↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

Cryogenic Propellant Transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

cryogenic propellant transfer↗