Search NASA⌕ Search

Engineering topics

Mark, Paul

Publications and source records attributed to Mark, Paul.

Automated Data Review of Analytical Laboratory Results at Los Alamos National Laboratory - 20299

Newport News Nuclear BWXT-Los Alamos, LLC (N3B) collects samples in support of the U.S. Department of Energy's (DOE) Office of Environmental Management (EM) Los Alamos Legacy Cleanup Contract (LLCC). N3B receives and reviews over 1.6 million sample data points annually in support of various ongoing environmental monitoring and remediation projects of the LLCC. N3B must demonstrate and document that reported external analytical laboratory data produced for the LLCC are of sufficient quality to fulfill their intended purpose and to support defensible decision making as described in EPA QA/G4 Guidance for the Data Quality Objectives Process 1994. In 2018, N3B assumed management of the LLCC along with the Environmental Information Management (EIM) database that contains all historical and current environmental data associated with the LLCC. The entire EIM database is shared between N3B, Triad National Security, LLC (Triad), and New Mexico Environment Department (NMED). These three parties jointly manage the database, its configuration, and changes / updates. All environmental data that are entered into EIM are updated and available, on a daily basis, in the linked public database Intellus New Mexico (Intellus). The quality and defensibility of the environmental data generated from sampling activities is a key component of an effective remediation process. Providing quality data is accomplished through a data assessment process that includes examination, verification, and validation. Examination is the assessment of completeness of the deliverables, identification of any reporting errors, and determining the usability of the data based on the laboratory's evaluation of its data as described in the case narrative received with the data. Verification consists of an evaluation of the Electronic Data Deliverables (EDD) data report to determine the extent to which the external analytical laboratories met method and contract-specific quality control and reporting requirements. Validation consists of determining the data quality and the extent to which the external analytical laboratories accurately and completely reported all sample and quality control results and satisfied all contract requirements. EIM contains an automatic Data Validation Module which performs automated data review (DVM ADR). DVM ADR is a tool to assist in the validation process. When DVM ADR is used in conjunction with manual examination of sample data packages, the combination of the two will meet and exceed the requirements of verification. N3B recognized an opportunity for process improvement, focusing on DVM ADR configuration and enhancements in EIM. Testing EIM's configuration provided proof of the DVM ADR's capabilities and flexibility to accurately perform routine data checks based on analytical methods and regulatory requirements. In addition, the DVM ADR module was improved through enhancements for all analytes, particularly upgrades for radiochemistry data. Extensive testing of the DVM ADR module occurred using EDDs from actual laboratory analyses on the EIM testing site. During this process, N3B manipulated EDD information to verify that the actual outcomes matched the expected outcomes. The results of this testing were shared with the database architects, and configuration improvements were identified to address these results. During this process, N3B identified that the radiochemical DVM ADR capabilities were underutilized, and so enhanced the DVM ADR functionality with respect to radioanalytical assessment. N3B environmental data uploads to Intellus on a daily basis from EIM, once the analytical data undergoes examination and verification. As such, it is important to have a high level of confidence in the quality and defensibility of the data. The process of manual examination, along with the DVM ADR, in conjunction with full validation of a percentage the data specified through the Data Quality Objectives greatly increases efficiency of data review and confidence level of the quality of the data, and gives the project managers, governmental offices, and the public expedited access to high-quality data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robust Method to Identify Groundwater Affected By Redox Conditions at Los Alamos National Laboratory Legacy Cleanup Site - 20497

To facilitate the mission of the Department of Energy's (DoE's) Environmental Management Program at Los Alamos National Laboratory (LANL), a significant number of groundwater monitoring wells with depths ranging from 152-396 meter were completed for characterization and monitoring. Groundwater at Los Alamos tends to be oxygen saturated with very low concentrations of organic matter. Drilling fluids can introduce residual carbon causing an increase in microbial activity and local reducing conditions around the well, potentially impacting representativeness of groundwater data quality for redox sensitive constituents. We assert that the redox state of the wells can robustly be identified by aqueous solution concentrations of iron and manganese. An automated review process has been built into a computer-based data management system enabling an efficient screening process for identifying reducing conditions that are not caught using standard data-validation protocol, and ensures that important data quality issues are thoroughly identified and addressed in an efficient and timely manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2018 Annual Site Environmental Report

Los Alamos National Laboratory’s (the Laboratory’s) annual site environmental reports are prepared annually by the Laboratory’s environmental organizations, as required by U.S. Department of Energy Order 231.1B, Administrative Change 1, Environment, Safety, and Health Reporting, and Order 458.1, Administrative Change 3, Radiation Protection of the Public and the Environment. The following chapters in this report discuss our success in complying with environmental laws, regulations, and orders (Chapter 2, Compliance Summary); how we manage the Laboratory’s environmental performance (Chapter 3, Environmental Programs); how we monitor for air emissions of radioactive materials and climate conditions (Chapter 4, Air Quality); how we monitor for effects of Laboratory operations on groundwater quality (Chapter 5, Groundwater Monitoring); how we monitor the movement of chemicals and radionuclides by storm water runoff and the levels of chemicals and radionuclides in deposited sediment (Chapter 6, Watershed Quality); how we monitor for the presence, levels, and effects of chemicals and radionuclides in plants, animals, soil, and vegetation (Chapter 7, Ecosystem Health); and finally, what radionuclide dose or risk from chemical exposure members of the public may experience as a result of Laboratory operations (Chapter 8, Public Dose and Risk Assessment). This report follows plain language guidelines, as required for federal agencies by the Plain Language Act of 2010. More information about plain language can be found at http://www.plainlanguage.gov/index.cfm. You will notice we have substantially reduced the use of acronyms and abbreviations and are using active voice and personal pronouns. We hope you find this report useful. If you have suggestions for improving this report, additional questions, or want a copy of this report, please contact us at envoutreach@lanl.gov, or call the Communications Office at 505-665-7000. This report, its supplemental tables, and the 2018 Annual Site Environmental Report Summary are available at http://www.lanl.gov/environment/environmental-report.php. Note: This document has been revised since it was initially published on September 23, 2019. The revisions included corrections to figure and table references, changes in heading levels, adding blank pages where appropriate, and changes of an editorial nature.

54 ENVIRONMENTAL SCIENCES↗