Search NASA⌕ Search

Engineering topics

Markey, Mia K.

Publications and source records attributed to Markey, Mia K..

Quantitative Assessment of Breast Cosmetic Outcome After Whole-Breast Irradiation

Purpose: To measure, by quantitative analysis of digital photographs, breast cosmetic outcome within the setting of a randomized trial of conventionally fractionated (CF) and hypofractionated (HF) whole-breast irradiation (WBI), to identify how quantitative cosmesis metrics were associated with patient- and physician-reported cosmesis and whether they differed by treatment arm. Methods and Materials: From 2011 to 2014, 287 women aged ≥40 with ductal carcinoma in situ or early invasive breast cancer were randomized to HF-WBI (42.56 Gy/16 fractions [fx] + 10-12.5 Gy/4-5 fx boost) or CF-WBI (50 Gy/25 fx + 10-14 Gy/5-7 fx). At 1 year after treatment we collected digital photographs, patient-reported cosmesis using the Breast Cancer Treatment and Outcomes Scale, and physician-reported cosmesis using the Radiation Therapy Oncology Group scale. Six quantitative measures of breast symmetry, labeled M1-M6, were calculated from anteroposterior digital photographs. For each measure, values closer to 1 imply greater symmetry, and values closer to 0 imply greater asymmetry. Associations between M1-M6 and patient- and physician-reported cosmesis and treatment arm were evaluated using the Kruskal-Wallis test. Results: Among 245 evaluable patients, patient-reported cosmesis was strongly associated with M1 (vertical symmetry measure) (P<.01). Physician-reported cosmesis was similarly correlated with M1 (P<.01) and also with M2 (vertical symmetry, P=.01) and M4 (horizontal symmetry, P=.03). At 1 year after treatment, HF-WBI resulted in better values of M2 (P=.02) and M3 (P<.01) than CF-WBI; treatment arm was not significantly associated with M1, M4, M5, or M6 (P≥.12). Conclusions: Quantitative assessment of breast photographs reveals similar to improved cosmetic outcome with HF-WBI compared with CF-WBI 1 year after treatment. Assessing cosmetic outcome using these measures could be useful for future comparative effectiveness studies and outcome reporting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing variability in the output of pattern classifiers using histogram shaping

Purpose: The authors present a novel technique based on histogram shaping to reduce the variability in the output and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs. Methods: The authors identify different sources of variability in the output of linear pattern classifiers with identical ROC curves, which also result in classifiers with differently distributed outputs. They theoretically develop a novel technique based on the matching of the histograms of these differently distributed pattern classifier outputs to reduce the variability in their (sensitivity, specificity) pairs at fixed decision thresholds, and to reduce the variability in their actual output values. They empirically demonstrate the efficacy of the proposed technique by means of analyses on the simulated data and real world mammography data. Results: For the simulated data, with three different known sources of variability, and for the real world mammography data with unknown sources of variability, the proposed classifier output calibration technique significantly reduced the variability in the classifiers' (sensitivity, specificity) pairs at fixed decision thresholds. Furthermore, for classifiers with monotonically or approximately monotonically related output variables, the histogram shaping technique also significantly reduced the variability in their actual output values. Conclusions: Classifier output calibration based on histogram shaping can be successfully employed to reduce the variability in the output values and (sensitivity, specificity) pairs of pattern classifiers with identical ROC curves, but differently distributed outputs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗