Search NASA⌕ Search

Engineering topics

Marshall, Thomas C.

Publications and source records attributed to Marshall, Thomas C..

Electric and kinematic structure of the Oklahoma mesoscale convective system of 7 June 1989

Balloon soundings of electric field in Oklahoma mesoscale convective systems (MCS) were obtained by the National Severe Storms Laboratory in the spring of 1989. This study focuses on a sounding made in the rearward edge of an MCS stratiform rain area on 7 June 1989. Data from Doppler radars, a lightning ground-strike location system, satellite, and other sources is used to relate the mesoscale attributes of the MCS to the observed electric-field profile.

Hunter, Steven M.↗

Electric field soundings through thunderstorms

Twelve balloon soundings of the electric field in thunderstorms are reported. The maximum magnitude of E in the storms averaged 96 +/-28 kV/m, with the largest being 146 kV/m. The maximum was usually observed between vertically adjacent regions of opposite charge. Using a 1D approximation to Gauss' law, four to ten charge regions in the storms are inferred. The magnitude of the density in the charge regions varied between 0.2 and 13 nC/cu m. The vertical extent of the charge regions ranged from 130 to 2100 m. None of the present 12 storms had charge distributions that fit the long-accepted model of Simpson et al. (1937, 1941) of a lower positive charge, a main negative charge, and an upper positive charge. In addition to regions similar to the Simpson model, the present storms had screening layers at the upper and lower cloud boundaries and extra charge regions, usually in the lower part of the cloud.

Marshall, Thomas C.↗

Electrical and kinematic structure of an Oklahoma mesoscale convective system

The case study examines the dynamics and kinematics of a mesoscale convective system (MCS) by comparing its meteorological parameters with in situ electrical measurements. Conventional MCS characteristics are reported including a rear inflow jet, wake low, and a bipolar cloud-to-ground pattern, but some nonclassical conditions are also reported. Horizontally long cloud-to-ground electrical strikes are noted which demonstrate that cloud-to-ground electrical data alone cannot entirely characterize stratiform electrification in MCSs.

Hunter, Steven M.↗

Electrical structure in two thunderstorm anvil clouds

Electrical structures in two thunderstorm anvil clouds (or 'anvils'), one in New Mexico, the other in Oklahoma, were investigated, using measurements of electric field by balloon-carried instruments and a one-dimensional model to calculate the time and spatial variations of electrical parameters in the clear air below the anvil. The electric field soundings through the two thunderstorm anvils showed similar charge structures; namely, negatively charged screening layers on the top and the bottom surfaces, a layer of positive charge in the interior, and one or two layers of zero charge. It is suggested that the positive charge originated in the main positive charge region normally found at high altitudes in the core of thunderclouds, and the negatively charged layers probably formed as screening layers, resulting from the discontinuity in the electrical conductivity at the cloud boundaries.

Marshall, Thomas C.↗

Mobile, high-wind, balloon-launching apparatus

In order to place instruments for measuring meteorological and electrical parameters into thunderstorms, an inexpensive apparatus has been developed which makes it possible to inflate, transport, and launch balloons in high winds. The launching apparatus is a cylinder of bubble plastic that is made by joining the sides of the cylinder together with a velcro rip strip. A balloon is launched by pulling the rip strip rapidly. This allows the balloon to pop upward into the ambient low-level wind and carry its instrumentation aloft. Different-sized launch tubes are constructed to accommodate particular sizes of balloons. Balloons have been launched in winds of about 20 m/s.

Rust, W. David↗