Search NASA⌕ Search

Engineering topics

Marshall, William J.

Publications and source records attributed to Marshall, William J..

At least 19 records

Verified, Archived, Library of Inputs and Data (VALID) Supporting Files

This dataset contains input, output, and sensitivity data files for computational simulations with the SCALE code system as part of the Verified, Archived Library of Inputs and Data (VALID). The simulations cover critical benchmark experiments from the International Criticality Safety Benchmark Evaluation Project. The files are to be housed in a public directory for distribution. The information contained in the files have been approved for release by the Organisation for Economic Co-operation and Development Nuclear Energy Agency (NEA). Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases.

keff↗

Neutron Absorber Plate Characterization Plan for Criticality Experiments Design [Slides]

The goal of this presentation is to show the feasibility of performing a critical experiment with a B 4 C/Aluminum alloy neutron absorber plate. The motivation of this experiment is to provide integral data on modern neutron absorber product “Boralcan” by Rio Tinto. In 2020, used in about 20% of spent fuel pools in the US, and in casks for storage and transportation in the US and in Europe. The added value of this experiment: Neutron absorber plate modeling method verification: homogeneous or not, a lot of potential savings by relaxing boron loading credit limits. No available critical benchmark involving Boralcan, other boron-related experiments are relatively old. Nuclear data validation for B, C, and Al in the form of B 4 C in Al matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutron Absorber Plate Characterization Plan for Criticality Experiments Design

After being used in nuclear installations, depleted fuel can still be highly reactive and must be handled securely to prevent any radiological or criticality concerns. In particular, spent fuel from use in nuclear power reactors must be stored and transported in specifically designed containers using neutron absorber materials to prevent criticality. Various neutron absorber material types exist and are manufactured by various entities, as thoroughly described in the Handbook of Neutron Absorber Materials for Spent Nuclear Fuel Storage and Transportation Applications written by EPRI. Presently, one of the most modern and most widely used types of neutron absorber material contains particles of boron carbide, or B 4 C, embedded in aluminum matrix: Boralcan, manufactured by Rio Tinto. It is very important for the community to know as much as possible about such neutron absorber materials. Therefore, in the recent years, a US Department of Energy National Nuclear Security Administration–Nuclear Criticality Safety Program funded project initiated design of an experiment that places Boralcan neutron-absorbing plates in an established critical assembly using low-enriched uranium fuel at the Sandia Pulsed Reactor Facility/Critical Experiments (SPRF/CX) apparatus at Sandia National Laboratories. The goal of the experiment is to produce high-quality benchmark data to submit to the International Criticality Safety Benchmark Evaluation Project (ICSBEP), for use in validating calculational tools and nuclear data by criticality safety analysts. The project, named IER-554, is currently in its final design stage, following a successful preliminary design. In the work documented in the design study, ten critical configurations using Boralcan neutron absorber plates were designed, and the experiment was proven to be feasible, with a predicted low k eff uncertainty around 100 pcm. An overview of the modeled cutout of the critical assembly with a Boralcan plate is shown in Figure 1, representing one of the configurations planned for the critical experiments. Before the plates are inserted in the critical assembly, it is necessary to know more about their composition and uniformity. This summary focuses on the plate characterization plans. Each plate will undergo (1) neutron transmission measurements at different locations to determine the 10 B areal density and (2) an in-depth x-ray computed tomography (XCT) examination to obtain the exact Sizes and distribution of the B4C powder particles inside the plates. In parallel, plate modeling studies are performed with a goal to determine the validity of the currently used approximation of modeling the neutron absorber plates as a homogeneous mixture of Aluminum 1100 alloy and B4C— instead of explicitly modeling the B4C particles. By using the experimental 10 B areal density measurements, and the exact size and location of the B4C particles obtained by XCT, a plate model can theoretically be built that reproduces the plate with extremely high fidelity. The results of this modeling study could increase the confidence of the criticality safety community in its modeling methods when using this type of neutron absorber material, and the industry could use these validations to change the boron loading credit limits from the U.S. Nuclear Regulatory Commission standard review plan for dry cask storage of spent nuclear fuel. The modeling calculations are performed with SCALE 6.3.0 using the KENO V.a sequence for criticality calculations with the ENDF/B-VIII.0 continuous-energy cross section library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 523 CED – 1 Report

This report documents the preliminary design phase of the Critical Experiment Design (CED-1) conducted as part of integral experiment request (IER) 523. The purpose of IER-523 is to determine critical configurations of 35 weight percent (wt%) enriched uranium dioxideberyllium oxide (UO 2 -BeO) material with Seven Percent Critical Experiment (7uPCX) fuels at Sandia National Laboratories (Sandia). Preliminary experiment design concepts, neutronic analysis results, and proposed paths for continuing the CED process are presented. This report builds on the feasibility and justification of experimental need report (CED-0) completed in December 2021.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the Sum-of-Fractions Methodology for Water and Polyethylene Moderated Systems

Sum-of-Fractions is a method intended to assure a subcritical margin for aqueous solutions and slurries of fissionable isotopes. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope in a mixture to its individual minimum subcritical mass limit is less than or equal to one. The basis of the Sum-of Fractions has historically been derived from allowances given in ANSI/ANS-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the Sum-of-Fractions for water or polyethylene moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 mAm, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water or polyethylene moderated and reflected mixtures containing the nuclides are evaluated with SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water or polyethylene moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the k eff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Devices and systems for material transportation

Various embodiments relate to devices for transporting high-assay low-enriched uranium (HALEU). A device may include at least one section, wherein each section of the at least one section includes a number of storage tubes. Each storage tube, which is configured to receive and hold a container, extends from adjacent a first end of the section toward a second, opposite end of the section. Each section further includes a number of flux traps, wherein each storage tube of the number of storage tubes is at least partially surrounded by a flux trap of the number of flux traps Associated systems are also disclosed.

Eidelpes, Elmar F.↗

Impact of Thermal Scattering Law on Similarity Assessment in Light-Water or Polyethylene-Moderated Systems

A collaborative effort between Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) is underway to provide a technical basis and methodology for the criticality safety community to use the sum of fractions (SoF) method for generating limits for mixtures of “selected actinide nuclides” included in the ANSI/ANS 8.15 standard. The PNNL scope in this project is to define a range of mixtures of 233 U, 235 U, and 239 Pu moderated with either light water or polyethylene and to examine the critical masses for these mixtures. The ORNL scope is primarily to provide validation support for these studies. More complete discussion of the project and its validation aspects will be presented at the upcoming International Conference on Nuclear Criticality Safety (ICNC) this Fall in Sendai, Japan. Clear differences in benchmark similarity to application systems as assessed by the integral parameter ck are noted in the validation studies performed as part of this project as a function of moderator. The c k value is a correlation coefficient that represents that amount of shared uncertainty in k eff due to cross sections between two systems. Individual nuclide-reaction contributions between the two systems can be simply summed to arrive at the total c k value. Specifically, the c k values for light-water–moderated solution experiments are higher for a water-moderated application than for a polyethylene-moderated application. This result is neither totally unexpected nor surprising, but the magnitude of the difference was difficult to anticipate. The TSUNAMI sequence, in the SCALE 6.2.4 code package developed by ORNL, was used to generate eigenvalues and reactivity effects with perturbation-theory based approach through sensitivity coefficients for all nuclides in the system with all reactions and energy groups. The TSUNAMI-Indices and Parameters (IP) sequence then uses the sensitivity data generated through TSUNAMI to generate relational parameters (i.e., c k ) to determine the degree of similarity between systems. One detail of the SCALE material and data implementation must be discussed at this point. Several thermal scattering laws (TSLs) are available for 1 H. SCALE uses a different nuclide ID number for each TSL; essentially, each version of 1 H is treated as a unique nuclide. For example, 1 H bound in water ( 1 H-H2O) is assigned the nuclide ID 1001, whereas 1 H bound in polyethylene (h-poly) is assigned the nuclide ID 9001001. The same cross section data are used for all reactions in 1 H, regardless of TSL, except for scattering below the TSL cutoff energy. TSUNAMI-IP treats different nuclide IDs as different nuclides; thus, no uncertainty is shared between 1 H-H2O and h-poly, despite much of the same data, including covariance data, being used for both nuclides. This presents a question: how much of the difference in assessed similarity between water- and polyethylene-moderated systems is due to the moderators, and how much is caused by the treatment of 1 H-H2O and h poly with cross section and covariance data. The extended edits generated by TSUANMI-IP allow for an investigation of this issue specifically, as well as a demonstration of the general techniques available within TSUNAMI to understand the results of the similarity assessment. This paper presents and analyzes the similarity assessment of both water- and polyethylene-moderated systems for a single benchmark: PST-002-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Design of Critical Experiments Involving Commercially Available B 4 C Neutron Absorber Plates with Low-Enriched UO 2 Fuel [Slides]

Conclusions of this presentation conclude that the experiment is feasible with at least 10 critical configurations, and low expected benchmark uncertainty. Potential high impact for the understanding of commercially used neutron absorber plates. Next steps are to think about other configurations: rod pitch, other rods – Finalize plate support, uncertainty study. Additionally, the potential use of IER-441 central test region to safely place the plate in the core. Next steps include the Determination of the neutron absorber plate characterization path and the Potential SINBAD benchmark of neutron transmission measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 305 CED-3a Summary Report

Under IER-305, critical experiments will be done with and without molybdenum sleeves on 7uPCX fuel rods. New critical assembly hardware has been designed and procured to accomplish the experiments with the fuel supported by in a 1.55 cm triangular-pitched array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Abstract]

The SCALE code package offers several nuclear data libraries to support Monte Carlo (MC) transport, as well as MC-based derivation of $\kappa$ eff sensitivity and uncertainty (S/U) data. The CSAS sequence using the KENO MC code can utilize continuous-energy (CE) cross sections, or pre-generated multigroup (MG) cross section libraries. The use of MG libraries introduces bias into calculations in exchange for faster transport solutions. The TSUNAMI-3D sequence also utilizes KENO MC calculations. TSUNAMI-3D has two CE calculational methods: the Iterated Fission Probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications, e.g., fissionable and polyethylene reflectors

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expansion of the ORNL VALID Library [Slides]

VALID continues as a library of high-quality models used for testing SCALE and nuclear data. Recent expansion of VALID was the largest impactful change in a decade. Adding 233 U experiments circa 2017 added more cases. There are a huge number of cases in the pipeline, but a lack of qualified staff and funding to complete reviews. Future plans should simplify the process and increase the availability of models and results for external users.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Request 305: CED-3b Summary Report

Under IER-305, critical experiments were done with and without molybdenum sleeves on 7uPCX fuel rods. The experiments were done in new critical assembly hardware designed to support the 7uPCX fuel in a 1.55 cm triangular-pitched array.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cumulative χ 2 Metric for VALID for ENDF/B-VII.1 and ENDF/B-VIII.0 in SCALE 6.3b9 [Slides]

Quantifying the performance of a new evaluation is difficult and doing so for a new library is significantly more challenging. Cumulative χ 2 metric is an established approach to comparing distributions. In this case, C/E results from different libraries. Andrei Trkov and Roberto Capote have published cumulative χ 2 results for ENDF/B-VIII.0. Cumulative χ 2 metric was recently calculated for VALID library maintained at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Selected Uses of TSUNAMI in Critical Experiment Design and Analysis

Validation in criticality safety is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 and enable investigation of the parameters at which such a critical condition is achieved. For the critical experiments used in a validation to capture the biases of the materials and neutron energy spectra of interest, those materials must be included in the experiment such that they influence k eff or another observable parameter with statistical significance. This paper discusses the use of sensitivity uncertainty (S/U) methods to develop critical experiments for various purposes. S/U techniques are useful for understanding the underlying components of nuclear data which affect the k eff or another parameter of a given configuration. S/U calculations are most commonly used to compare existing experiments to applications of interest; however, S/U techniques can also be used to identify, optimize, or assess features of proposed experiments so that they can better test specific portions of nuclear data or match an application of interest. The S/U techniques discussed here are from the TSUNAMI code system. The two primary codes discussed in this work are TSUNAMI-3D, which implements the KENO criticality code to calculate the sensitivity of k eff to nuclear data, and TSAR, which calculates the sensitivity of a reactivity difference between two configurations based on their TSUNAMI-3D generated sensitivity profiles. The methods used in these tools are discussed in more detail in the SCALE manual. This paper is one of a series on the development and use of TSUNAMI tools. The other papers address development of TSUNAMI methods and a review of TSUNAMI applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Testing of ENDF/B-VIII.0 at ORNL [Slides]

This presentation provides an overview of comparisons of ENDF/B-VII.1 and ENDF/B-VIII.0 and uses VALID suite to test >600 cases with ENDF/B-VII.1 and ENDF/B-VIII.0 in KENO V.a/KENO-VI, although a limited number of cases have been tested with TSUNAMI. It provides a results summary of KENO V.a/KENO-VI with a pooled results summary. The presentation also discusses changes for LCT experiments, MCT experiments, MST experiments, and PST experiments. A few words about graphite are also provided and the presentation states that graphite performance investigated across ENDF/B-VII.0, ENDF/B-VII.1, and ENDF/B-VIII.0 for MSR and HTGR models. A brief summary of the results is presented to make sure the Validation Committee is aware of the work. Also presented is an Eigenvalue comparison with a graphite moderated system, and comparison between an HTR-10 pebble model ENDF/B-VII.1 vs. ENDF/B-VIII.0, which provides different graphite data. In conclusion, ORNL has recently completed a comparison of ENDF/B-VIII.0 and ENDF/B-VII.1 using the VALID library. Work is also being performed for advanced reactor applications. Other efforts on-going and they are also trying to investigate more intermediate spectrum cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗