Search NASA⌕ Search

Engineering topics

Marsili, P

Publications and source records attributed to Marsili, P.

Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasma

Two Doppler spectroscopy diagnostics with complementary capabilities are developed to measure the ion temperatures and velocities of FRC plasmas in the C-2 device. First, the multichord ion doppler diagnostic can simultaneously measure 15 chords of the plasma using an image intensified camera. Second, a single-chord fast-response ion Doppler diagnostic provides much higher faster time response by using a 16-channel photo-multiplier tube array. To study the neutral density of deuterium under different wall and plasma conditions, a highly sensitive eight-channel D-alpha diagnostic has been developed and calibrated for absolute radiance measurements. These spectroscopic diagnostics capabilities, combined with other plasma diagnostics, are helping to understand and improve the field reversed configuration plasmas in the C-2 device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact high-speed high-sensitivity second-harmonic interferometer for electron density measurement

A second-harmonic interferometer based on a CW Nd:YAG laser is presented. The device is extremely compact and versatile and is developed for line-integrated electron density measurements in large plasma machines. A sensitivity in measuring line-integrated electron density of 4x10{sup 13} cm{sup -2} with time resolution of 8 {mu}s, and 10{sup 13} cm{sup -2} with time resolution of 50 {mu}s, is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗