Engineering topics
Martinez, M.
Publications and source records attributed to Martinez, M..
Pre-equilibrium evolution of conserved charges with initial conditions in the ICCING Monte Carlo event generator
Heavy-ion collisions can be well described through relativistic viscous hydrodynamics, but questions still remain when hydrodynamics is applicable because the initial state may begin very far from equilibrium. Thus, a pre-equilibrium evolution phase is used to bridge the gap between the initial state and hydrodynamics. KøMPøST is one such pre-equilibrium model that propagates the energy-momentum tensor by decomposing it into the background and fluctuations around that background, whose evolution is captured by Green's functions. We extend this formalism to include conserved charges and calculate the corresponding nonequilibrium Green's functions in the relaxation-time approximation. The ICCING algorithm initializes conserved charges in the initial state by sampling $g$ → $q$$\overline{q}$ splitting probabilities and is, thus, perfectly positioned to implement Green's functions for charge propagation. As a result, we show that this method alters the initial-state charge geometries and is applicable in central to mid-central collisions.
Machine Learning Techniques for Pile-Up Rejection in Cryogenic Calorimeters
CUORE Upgrade with Particle IDentification (CUPID) is a foreseen ton-scale array of Li 2 MoO 4 (LMO) cryogenic calorimeters with double readout of heat and light signals. Its scientific goal is to fully explore the inverted hierarchy of neutrino masses in the search for neutrinoless double beta decay of 100 Mo. Pile-up of standard double beta decay of the candidate isotope is a relevant background. We generate pile-up heat events via injection of Joule heater pulses with a programmable waveform generator in a small array of LMO crystals operated underground in the Laboratori Nazionali del Gran Sasso, Italy. This allows to label pile-up pulses and control both time difference and underlying amplitudes of individual heat pulses in the data. We present the performance of supervised learning classifiers on data and the attained pile-up rejection efficiency.
Optimization of a single module of CUPID
CUPID is the next generation experiment which will use scintillating cryogenic calorimeters to search for the neutrinoless double β decay. This unobserved process would shed light on the nature of the neutrino, which up to our knowledge could be a Majorana or a Dirac particle, and would give us an important hint to explain the lack of antimatter in the universe. This ambitious search needs a detector with unique characteristics such as an extremely low background level and an excellent energy resolution. CUPID is now in advanced R&D state to optimize the detector design in order to completely exploit the potentialities of scintillating cryogenic calorimeters. In the following I will describe the test performed at the LNGS (Laboratori Nazionali del Gran Sasso) of a single module of the future CUPID detector. In this contribution we present the performance obtained with a novel assembly concept, proving that it matches the requirements for CUPID.
Searching for New Physics in two-neutrino double beta decay with CUPID
In the past few years, attention has been drawn to the fact that a precision analysis of two-neutrino double beta decay (2υββ) allows the study of interesting physics cases like the emission of Majoron bosons and possible Lorentz symmetry violation. These processes modify the summed-energy distribution of the two electrons emitted in 2υββ. CUPID is a next-generation experiment aiming to exploit 100 Mo-enriched scintillating Li 2 MoO 4 crystals, operating as cryogenic calorimeters. Given the relatively fast half-life of 100 Mo 2υββ and the large exposure that can be reached by CUPID, we expect to measure with very high precision the 100 Mo 2υββ spectrum shape, reaching great sensitivities in the search for distortions induced by the physics beyond the Standard Model. In this contribution, we present the CUPID exclusion sensitivity for such New Physics processes, as well as the preliminary projected background of CUPID.
Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs
To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.
Background identification in cryogenic calorimeters through $\alpha -\alpha$ delayed coincidences
Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of $\alpha -\alpha$ delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the $\alpha$ decay position.
Novel technique for the study of pileup events in cryogenic bolometers
Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.
Cryogenic control system operational experience at SNS
Abstract The helium cryogenic system at Spallation Neutron Source (SNS) provides cooling to 81 superconducting radio frequency cavities. To support the operation of the cryogenic facility, a highly reliable control system consisting of software, hardware, and Human Machine Interface (HMI) has been developed and improved during the first fifteen years of operation. Integrating the cryogenic control system with other subsystems of the SNS complex is an important aspect to the success of the operation. The operating experience, lessons learned and recommendations to consider for future facilities will be detailed in this paper.
Perspectives of lowering CUORE thresholds with Optimum Trigger
CUORE is a cryogenic experiment that focuses on the search of neutrinoless double beta decay in 130Te and it is located at the Gran Sasso National Laboratories. Its detector consists of 988 TeO 2 crystals operating at a base temperature of ~10 mK. It is the first ton-scale bolometric experiment ever realized for this purpose. Thanks to its large target mass and ultra-low background, the CUORE detector is also suitable for the search of other rare phenomena. In particular the low energy part of the spectra is interesting for the detection of WIMP-nuclei scattering reactions. One of the most important requirements to perform these studies is represented by the achievement of a stable energy threshold lower than 10 keV. Here, the CUORE capability to accomplish this purpose using a low energy software trigger will be presented and described.
Laser-driven x-ray and proton micro-source and application to simultaneous single-shot bi-modal radiographic imaging
Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.
First results from the CUORE experiment
CUORE (Cryogenic Underground Observatory for Rare Events) is a ton-scale experiment aiming to the search of neutrino-less double beta decay in 130 Te with a projected sensitivity on the Majorana effective mass close to the inverted hierarchy region. The CUORE detector consists of a segmented array of 988 TeO 2 bolometers, organized in 19 towers and operated at a temperature of about 10 mK thanks to a custom cryogenic system which, besides the uncommon scale, observes several constraints from the radio-purity of the materials to the mechanical decoupling of the cooling systems. The successful commissioning of the CUORE cryogenic system has been completed early in 2016 and represents an outstanding achievement by itself. The installation of the detector proceeded along 2016 followed by the cooldown to base temperature at the beginning of 2017. The CUORE detector is now operational and has been taking science data since Spring 2017. With the first ~3 weeks of collected data, we present here the most stringent constraint on the 130 Te half-live for the neutrino-less double beta decay.
Initial performance of the CUORE detector
CUORE, the Cryogenic Underground Observatory for Rare Events, is an experiment searching for the neutrinoless double-beta decay of 130 Te. The first CUORE dataset was acquired in May and June 2017 and consisted of 10.6 kg-yr of TeO 2 exposure, with several days of calibration data before and after the physics dataset. We discuss here the initial performance of the CUORE detector and cryostat in this first dataset.
Critical behavior of the bulk viscosity in QCD
Not Available
Double-beta decay of $^{130}\hbox {Te}$ to the first $0^+$ excited state of $^{130}\hbox {Xe}$ with CUORE-0
We report on a search for double beta decay of 130 Te to the first 0 + excited state of 130 Xe using a 9.8kg·yr exposure of 130 Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double beta decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $T_{0_1^+}^{0ν}$ > 7.9·10 23 yr and $T_{0_1^+}^{2ν}$ > 2.4·10 23 yr (90%CL). Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $T_{0_1^+}^{0ν}$ > 1.4·10 24 yr and $T_{0_1^+}^{2ν}$ > 2.5·10 23 yr (90%CL).
The response function of Fujifilm BAS-TR imaging plates to laser-accelerated titanium ions
Calibrated diagnostics for energetic particle detection allow for the systematic study of charged particle sources. The Fujifilm BAS-TR imaging plate (IP) is a reusable phosphorescent detector for radiation applications such as x-ray and particle beam detection. The BAS-TR IP has been absolutely calibrated to many low-Z (low proton number) ions, and extending these calibrations to the mid-Z regime is beneficial for the study of laser-driven ion sources. The Texas Petawatt Laser was used to generate energetic ions from a 100 nm titanium foil, and charge states Ti 10+ through Ti 12+ , ranging from 6 to 27 MeV, were analyzed for calibration. A plastic detector of CR-39 with evenly placed slots was mounted in front of the IP to count the number of ions that correspond with the IP levels of photo-stimulated luminescence (PSL). Here, a response curve was fitted to the data, yielding a model of the PSL signal vs ion energy. Comparisons to other published response curves are also presented, illustrating the trend of PSL/nucleon decreasing with increasing ion mass.
Beam distortion effects upon focusing an ultrashort petawatt laser pulse to greater than 10 22 W/cm 2
When an ultrashort laser pulse is tightly focused to a size approaching its central wavelength, the properties of the focused spot diverge from the diffraction-limited case. Here, we report on this change in behavior of a tightly focused petawatt-class laser beam by an $f/1$ off-axis parabolic mirror (OAPM). Considering the effects of residual aberration, the spatial profile of the near-field, and pointing error, we estimate the deviation in peak intensities of the focused spot from the ideal case. Here, we verify that the estimated peak intensity values are within an acceptable error range of the measured values. With the added uncertainties in target alignment, we extend the estimation to infer on-target peak intensities of ≥10 22 W/cm 2 for a target at the focal plane of this $f/1$ OAPM.
Stochastic hydrodynamics and long time tails of an expanding conformal charged fluid
Not Available