Test Report for DPP-1 Regulatory Compliance Testing. Volume 1 - Main Report

Consolidated Nuclear Security, LLC (CNS), the management and operating contractor for the Y-12 National Security Complex (Y-12) for the National Nuclear Security Administration (NNSA), is currently responsible for the regulatory testing of a new Type B fissile material shipping package called the Defense Programs Package (DPP)-1. The DPP-1 is a drum packaging with an inner liner and a removable lid. Both the drum body and the lid are filled with an impact-limiting, thermal-insulating material that protects the inner containment vessel (CV) during normal conditions of transport (NCT) and hypothetical accident conditions (HAC) as defined by 10 US code of Federal Regulations (CFR) 71. In fiscal year 2021, the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP), located at the National Transportation Research Center (NTRC), conducted Type B performance tests as prescribed in Title 10 Code of Federal Regulations Part 71 (10 CFR 71) on seven DPP-1 prototype units. This test report documents test unit (TU) preparation, pretest condition, conditioning of each TU, NCT and HAC testing, and posttest measurements and observations made of the damage resulting from these tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test Report for the Qualification Testing of the ORNL-SFC-W-1 Special Form Capsule

Three prototypes the ORNL-SFC-W-1 special form capsules (SFCs) of the same design were evaluated to determine if the requirements of Title 49, Code of Federal Regulations (CFR), Part 173.469, Tests for Special Form Class 7 (Radioactive) Materials, were met. The results of the special form tests are documented in this test report. This report describes the special form testing activities performed on the three ORNL-SFC-W-1 capsules. The test units were designated as TU-1, TU-2 and TU-3. TU-1 was subjected to leak testing, impact testing and percussion testing. TU-1 was leak tested using the leak rate test specified in 49 CFR 173.469(a)(4)(i). The impact test was conducted according to the requirements in 49 CFR 173.469 (b)(1). The percussion test that was carried out on TU-1 was conducted in accordance with 49 CFR 173.469 (b)(2). Both TU-2 and TU-3 were subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469(b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests as specified in American National Standards Institute (ANSI) N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in American Society for Testing and Measurement (ASTM) E 493. The determined standardized leak rates obtained from the test and the calculations for all the test units met the requirements for special form certification. The testing was performed under the direction of the Oak Ridge National Laboratory (ORNL) Package Testing Program (PTP).

42 ENGINEERING↗