Search NASA⌕ Search

Engineering topics

Martz, Harry E.

Publications and source records attributed to Martz, Harry E..

At least 19 records

Dose Measurement on Microfocus Computed Tomography Scanner

This Standard Operating Procedure (SOP) outlines the steps for measuring dose in x-ray computed tomography (CT) scans [1] on the MicroCT (MCT) system at the High Explosives Application Facility (HEAF) and other systems relevant to the Livermore Explosives Detection Program (LEDP). These systems include: the DHS LLNL MCT in HEAF, aka HEAFCAT, DHS LLNL MCT Testbed (TB) in B327, and the MCTs at TRMG, HEX2, HMEX, CBX, and IPMO, as described in Section 4.

42 ENGINEERING↗

HME MicroCT Data Acquisition, Processing and Data Request Overview

This document is a short summary of the steps required for MicroCT evaluation of a specimen. This includes data acquisition through image analysis, for the Explosives Threat Assessment (ETA) program. Expected outputs for each stage are outlined. Information and data shall be shipped to LLNL as described herein.

42 ENGINEERING↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Method for system-independent material characterization from spectral X-ray CT

We propose a method for material characterization using Spectral X-ray Computed Tomography (SCT). Our SCT method takes advantage of recently-developed MultiX ME 100 photon counting detectors to simultaneously measure the energy dependence of a material's linear attenuation coefficient (LAC). Relative electron density (ρ e ) and effective atomic number (Z e ) are estimated directly from the energy-dependent LAC measurements. The method employs a spectral correction algorithm and automated selection and weighting of the energy bins for optimized performance. When examining materials with Z e ≤ 23, this method achieves accuracy comparable to traditional dual-energy CT, which is often realized through consecutive data acquisitions, and is compatible with any spectral detector. The method disregards data in photon starved energy channels improving the detection of highly attenuating materials, compared to techniques that use energy integrating detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to Extract System-Independent Material Properties From Dual-Energy X-Ray CT

In 2016, we published a method for processing dual-energy computed tomography (DECT) data called system-independent rho-e/Z-e (ρ e /Z e ) or SIRZ. Using data from multiple DECT systems and spectra, SIRZ estimated the electron density ρ e and effective atomic number Z e (based on published X-ray cross sections), for a set of known specimens. However, the decomposition process required complex spectral modeling of the DECT system, which made SIRZ difficult to implement and automate. This paper describes the subsequent work on “SIRZ-2” to simplify the spectral modeling, automate the process, and improve its range and versatility. The SIRZ-2 basis functions are more accurate for the X-ray energy range (<;200 keV) and materials that are common to DECT applications in security and nondestructive characterization. To evaluate the SIRZ-2 performance, eight well-characterized specimens (with Z e of 6-20) were scanned with multiple spectral pairs (up to 200 keV) on seven different DECT systems, including a commercial airport luggage scanner. For these varied tests, the average SIRZ-2 relative errors for ρ e estimates were four times lower (0.7% compared to 3.0% for SIRZ), while average Z e relative errors were comparably low for both methods (<;1.5%). Average precision errors were also low (<;2.3% for both). SIRZ-2 produces accurate, repeatable, and system-independent material property estimates of (ρ e , Z e ) that can be directly compared across DECT systems and over time.

42 ENGINEERING↗

An Overview of Nondestructive Evaluation and Characterization at Lawrence Livermore National Laboratory

For more than 60 years, Lawrence Livermore National Laboratory (LLNL) has developed and employed advanced technologies in both nondestructive evaluation (NDE) and nondestructive characterization (NDC) to enhance national security. Additonally, the Laboratory established an extensive array of NDC capabilities that enable the inspection and characterization of virtually every element on the periodic table. This allows for the evaluation of structures of interest with densities ranging from ~20 mg/cm 3 to approximately 20 g/cm 3 , across length scales from nanometers to meters, and over time scales ranging from microseconds to decades. This paper provides an overview of the NDE and NDC activities at LLNL, illuminating current research and development interests in well-established areas such as weapons and explosives research, and in new areas such as additive manufacturing. Traditional NDC techniques, such as X-ray radiography and computed tomography, are also discussed. Furthermore, new approaches, such as X-ray phase-contrast imaging and X-ray ptychography, are examined.

36 MATERIALS SCIENCE↗

Similarity Analysis: Comparison of a Standard 60mL With a 50mL Container for MicroCT

A 50mL container with a one inch outer diameter has been proposed for holding specimen materials scanned at LLNL and Tyndall Air Force Research Laboratory (TAFRL). In order to determine whether or not this new container would significantly affect MicroCT results, a similarity analysis procedure developed at LLNL was used. This procedure compares multiple first and second order statistics obtained from CT reconstructed images generated by the MicroCT analysis process, and prescribes similarity constraints as guidance. For this study, water was scanned on the MicroCT system at LLNL, twice in the standard 60mL container and twice in the proposed 50mL container. Data were analyzed following the Standard Operating Procedure (SOP) for MicroCT analysis. Comparison of analytical results shows that the new container does not satisfy all similarity analysis criteria (certain second order statistics are outside of similarity analysis constraints).

42 ENGINEERING↗

Similarity Analysis: Comparison of a Standard 60mL With an Anti-Static Container for MicroCT

Pursuant to safety concerns, an anti-static container has been proposed for holding specimen materials scanned by an International Partner (IP) on a MicroCT system. In order to determine whether or not this new container would significantly affect MicroCT results, a similarity analysis procedure developed at LLNL was used. This procedure compares multiple first and second order statistics obtained from CT reconstructed images generated by the MicroCT analysis process, and prescribes similarity constraints as guidance. For this study, water was scanned on a MicroCT system in both a standard container and the proposed anti-static container under Test Plan 83. Data were analyzed following the Standard Operating Procedure (SOP) for MicroCT analysis. Comparison of analytical results shows that the anti-static container satisfies all similarity analysis criteria.

42 ENGINEERING↗

Summary Statistics for TA_SH01_130819: Micro-CT Data Acquired at LLNL, Specimen 1 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_SH01_130819, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images. The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_LT03_130723: Micro-CT Data Acquired at LLNL, Specimen 2 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79.

42 ENGINEERING↗

Summary Statistics for TA_LP04_130708: Micro-CT Data Acquired at LLNL, Specimen 4 of 4

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79.

42 ENGINEERING↗

X-ray Nanoscope for Electronics Assurance

The United States does not have a comprehensive program to certify that integrated circuits (ICs) going into U.S. weapons systems do not contain malicious circuits. Destructive techniques are slow and labor intensive. In response to these concerns, DARPA initiated its TRUST in Integrated Circuits program to develop nondestructive technologies that will ensure the trust of ICs used in military systems, but designed and fabricated under untrusted conditions.

42 ENGINEERING↗

Plan for the Purchase of MCT and EDS Reference Materials, Source Filters, Cu Strips, and Carousel Sub-Assemblies

The goal of this effort is to improve the quality and consistency of MCT and EDS data across the program. New references, aluminum (Al) and Cu filters, and Cu strips will be of known high purity and quality, traceable to documented chemical analyses. A single Program organization will be responsible to purchase, fabricate, assemble, inspect, control, and supply these items to the Program to ensure adequate and uniform quality and quality control.

42 ENGINEERING↗

Image Reconstruction of Imatron Electron-Beam Tomography Data

In this paper we describe the development of a filtered backprojection image reconstruction algorithm for an Imatron Electron-Beam Tomography (EBT) scanner. Raw data, software to perform data correction routines, and a technical document on the data format were all provided by Imatron. This document describes the basic geometry of the EBT scanner and the steps of the image reconstruction algorithm. Finally we demonstrate that the image quality our reconstruction algorithm is comparable with the reconstructed images provided by Imatron on an airport luggage data set.

42 ENGINEERING↗

FY2011 Engineering Innovations, Research, and Technology Report

This report summarizes key research, development, and technology advancements in Lawrence Livermore National Laboratory’s Engineering Directorate for FY2011. These efforts exemplify Engineering’s nearly 60-year history of developing and applying the technology innovations needed for the Laboratory’s national security missions, and embody Engineering’s mission to “Enable program success today and ensure the Laboratory’s vitality tomorrow.

42 ENGINEERING↗

Using Segmentation in CT Metal Artifact Reduction

Metal artifact reduction methods in computed tomography replace the projection data passing through metals with an estimate of the true data. Inaccurate estimation leads to the generation of secondary artifacts. Data estimates can be improved by the use of prior knowledge of the projection data. In this paper, a method has been created to generate a prior image. The method uses computer vision techniques to segment regions of the initially reconstructed image and then discriminates between regions that are likely to be artifacts and anatomical structures. Results on test images show that metal artifacts are reduced and that few secondary artifacts are present, even in the case of multiple metal objects.

42 ENGINEERING↗

MicroCT: Automated Analysis of CT Reconstructed Data of Home Made Explosive Materials Using the Matlab MicroCT Analysis GUI

This Standard Operating Procedure (SOP) provides the specific procedural steps for analyzing reconstructed CT images obtained under the IDD Standard Operating Procedures for data acquisition and MicroCT image reconstruction, per the IDD Quality Assurance Plan for MicroCT Scanning. Although intended to apply primarily to MicroCT data acquired in the HEAFCAT Facility at LLNL, these procedures may also be applied to data acquired at Tyndall from the YXLON cabinet and at TSL from the HEXCAT system. This SOP also provides the procedural steps for preparing the tables and graphs to be used in the reporting of analytical results. This SOP applies to production work - for R and D there are two other semi-automated methods as given in [4, 5].

42 ENGINEERING↗