The role of thermal energy storage in industrial energy conservation

Thermal Energy Storage for Industrial Applications is a major thrust of the Department of Energy's Thermal Energy Storage Program. Utilizing Thermal Energy Storage (TES) with process or reject heat recovery systems is shown to be extremely beneficial for several applications. Recent system studies resulting from contracts awarded by the Department of Energy (DOE) identified four especially significant industries where TES appears attractive - food processing, paper and pulp, iron and steel, and cement. Potential annual fuel savings with large scale implementation of near term TES systems for these industries is over 9,000,000 bbl of oil. This savings is due to recuperation and storage in the food processing industry, direct fuel substitution in the paper and pulp industry and reduction in electric utility peak fuel use through inplant production of electricity from utilization of reject heat in the steel and cement industries.

Duscha, R. A.↗

Thermal storage for industrial process and reject heat

Industrial production uses about 40% of the total energy consumed in the United States. The major share of this is derived from fossil fuel. Potential savings of scarce fuel is possible through the use of thermal energy storage (TES) of reject or process heat for subsequent use. Results of study contracts awarded by the Department of Energy (DOE) and managed by the NASA Lewis Research Center have identified three especially significant industries where high temperature TES appears attractive - paper and pulp, iron and steel, and cement. Potential annual fuel savings with large scale implementation of near-term TES systems for these three industries is nearly 9 million bbl of oil.

Duscha, R. A.↗

Thermal storage for industrial process and reject heat

Industrial production uses about 40 percent of the total energy consumed in the United States. The major share of this is derived from fossil fuel. Potential savings of scarce fuel is possible through the use of thermal energy storage (TES) of reject or process heat for subsequent use. Three especially significant industries where high temperature TES appears attractive - paper and pulp, iron and steel, and cement are discussed. Potential annual fuel savings, with large scale implementation of near-term TES systems for these three industries, is nearly 9,000,000 bbl of oil.

Duscha, R. A.↗

Thermal storage for electric utilities

Applications of the thermal energy storage (TES) principle (storage of sensible heat or latent heat, or heat storage in reversible chemical reactions) in power systems are evaluated. Load leveling behind the meter, load following at conventional thermal power plants, solar thermal power generation, and waste heat utilization are the principal TES applications considered. Specific TES examples discussed include: storage heaters for electric-resistance space heating, air conditioning TES in the form of chilled water or eutectic salt baths, hot water TES, and trans-seasonal storage in heated water in confined aquifers.

Swet, C. J.↗

An analytical study of reduced-gravity propellant settling

Full-scale propellant reorientation flow dynamics for the Centaur D-1T fuel tank were analyzed. A computer code using the simplified marker and cell technique was modified to include the capability for a variable-grid mesh configuration. Use of smaller cells near the boundary, near baffles, and in corners provides improved flow resolution. Two drop tower model cases were simulated to verify program validity: one case without baffles, the other with baffles and geometry identical to Centaur D-1T. Flow phenomena using the new code successfully modeled drop tower data. Baffles are a positive factor in the settling flow. Two full-scale Centaur D-1T cases were simulated using parameters based on the Titan/Centaur proof flight. These flow simulations indicated the time to clear the vent area and an indication of time to orient and collect the propellant. The results further indicated the complexity of the reorientation flow and the long time period required for settling.

Bradshaw, R. D.↗

Atmospheric temperature measurements by Raman laser scattering

System makes continuous synoptic measurement of air temperatures and temperature profiles from the ground in real time. Development is based on principle that intensity distribution of Raman scattered laser light is a function of temperature and it is theoretically possible to measure air temperature by analyzing its Raman spectrum.

Masica, W. J.↗

Low gravity reorientation in a scale-model Centaur liquid-hydrogen tank

An experiment was conducted to investigate the process of liquid reorientation from one end of a scale-model Centaur liquid-hydrogen tank to the other end by means of low-level accelerations. Prior to reorientation, the liquid was stabilized at the top of the tank at a Bond number of 15. Tanks both with and without ring baffles and with tank radii of 5.5 and 7.0 centimeters were used in the study. Reorientation acceleration values were varied to obtain Bond numbers of 200 and 450. Liquid fill levels of 20 and 70 percent were used. From the data in this study, relations were developed to estimate reorientation event times in unbaffled tanks through the point of final liquid clearing from the top of the tank. The insertion of ring baffles drastically changed the reorientation flow profiles but resulted in only minor differences in the times of tank-top uncovering and liquid collection.

Salzman, J. A.↗

Determining gas temperatures from laser scattering.

Lidar techniques may be applicable to inelastic, Raman scattering. When a light beam interacts with gas molecules, the energies of scattered photons may be increased or decreased relative to the incident photons. The Raman return signal can theoretically yield information on gas pressure, temperature, and molecular species concentration. The temperature can be calculated from the measurement of two scattered Raman rotational line intensities. Questions of measurement accuracy, line selection, and multiple line ratios are considered. The measurement apparatus is discussed together with the measurement techniques.

Salzman, J. A.↗