Search NASA⌕ Search

Engineering topics

Mason, Mary L.

Publications and source records attributed to Mason, Mary L..

Experimental Study of an Axisymmetric Dual Throat Fluidic Thrust Vectoring Nozzle for Supersonic Aircraft Application

An axisymmetric version of the Dual Throat Nozzle concept with a variable expansion ratio has been studied to determine the impacts on thrust vectoring and nozzle performance. The nozzle design, applicable to a supersonic aircraft, was guided using the unsteady Reynolds-averaged Navier-Stokes computational fluid dynamics code, PAB3D. The axisymmetric Dual Throat Nozzle concept was tested statically in the Jet Exit Test Facility at the NASA Langley Research Center. The nozzle geometric design variables included circumferential span of injection, cavity length, cavity convergence angle, and nozzle expansion ratio for conditions corresponding to take-off and landing, mid climb and cruise. Internal nozzle performance and thrust vectoring performance was determined for nozzle pressure ratios up to 10 with secondary injection rates up to 10 percent of the primary flow rate. The 60 degree span of injection generally performed better than the 90 degree span of injection using an equivalent injection area and number of holes, in agreement with computational results. For injection rates less than 7 percent, thrust vector angle for the 60 degree span of injection was 1.5 to 2 degrees higher than the 90 degree span of injection. Decreasing cavity length improved thrust ratio and discharge coefficient, but decreased thrust vector angle and thrust vectoring efficiency. Increasing cavity convergence angle from 20 to 30 degrees increased thrust vector angle by 1 degree over the range of injection rates tested, but adversely affected system thrust ratio and discharge coefficient. The dual throat nozzle concept generated the best thrust vectoring performance with an expansion ratio of 1.0 (a cavity in between two equal minimum areas). The variable expansion ratio geometry did not provide the expected improvements in discharge coefficient and system thrust ratio throughout the flight envelope of typical a supersonic aircraft. At mid-climb and cruise conditions, the variable geometry design compromised thrust vector angle achieved, but some thrust vector control would be available, potentially for aircraft trim. The fixed area, expansion ratio of 1.0, Dual Throat Nozzle provided the best overall compromise for thrust vectoring and nozzle internal performance over the range of NPR tested compared to the variable geometry Dual Throat Nozzle.

Flamm, Jeffrey D.↗

Design Enhancements of the Two-Dimensional, Dual Throat Fluidic Thrust Vectoring Nozzle Concept

A Dual Throat Nozzle fluidic thrust vectoring technique that achieves higher thrust-vectoring efficiencies than other fluidic techniques, without sacrificing thrust efficiency has been developed at NASA Langley Research Center. The nozzle concept was designed with the aid of the structured-grid, Reynolds-averaged Navier-Stokes computational fluidic dynamics code PAB3D. This new concept combines the thrust efficiency of sonic-plane skewing with increased thrust-vectoring efficiencies obtained by maximizing pressure differentials in a separated cavity located downstream of the nozzle throat. By injecting secondary flow asymmetrically at the upstream minimum area, a new aerodynamic minimum area is formed downstream of the geometric minimum and the sonic line is skewed, thus vectoring the exhaust flow. The nozzle was tested in the NASA Langley Research Center Jet Exit Test Facility. Internal nozzle performance characteristics were defined for nozzle pressure ratios up to 10, with a range of secondary injection flow rates up to 10 percent of the primary flow rate. Most of the data included in this paper shows the effect of secondary injection rate at a nozzle pressure ratio of 4. The effects of modifying cavity divergence angle, convergence angle and cavity shape on internal nozzle performance were investigated, as were effects of injection geometry, hole or slot. In agreement with computationally predicted data, experimental data verified that decreasing cavity divergence angle had a negative impact and increasing cavity convergence angle had a positive impact on thrust vector angle and thrust efficiency. A curved cavity apex provided improved thrust ratios at some injection rates. However, overall nozzle performance suffered with no secondary injection. Injection holes were more efficient than the injection slot over the range of injection rates, but the slot generated larger thrust vector angles for injection rates less than 4 percent of the primary flow rate.

Flamm, Jeffrey D.↗

Static Investigation of a Multiaxis Thrust-Vectoring Nozzle With Variable Internal Contouring Ability

The thrust efficiency and vectoring performance of a convergent-divergent nozzle were investigated at static conditions in the model preparation area of the Langley 16-Foot Transonic Tunnel. The diamond-shaped nozzle was capable of varying the internal contour of each quadrant individually by using cam mechanisms and retractable drawers to produce pitch and yaw thrust vectoring. Pitch thrust vectoring was achieved by either retracting the lower drawers to incline the throat or varying the internal flow-path contours to incline the throat. Yaw thrust vectoring was achieved by reducing flow area left of the nozzle centerline and increasing flow area right of the nozzle centerline; a skewed throat deflected the flow in the lateral direction.

Wing, David J.↗

Experimental investigation of spherical-convergent-flap thrust-vectoring two-dimensional plug nozzles

An experimental investigation of multiaxis thrust vectoring nozzles with spherical convergent flaps (SCF) and a convertible (in-flight deployable) centerline plug were tested in the NASA-Langley 16-Foot Transonic Tunnel Static Test Facility. Parameters tested during the static test included plug length, external shroud length, shroud internal angle, and yaw vector angle. Results indicated that the SCF convertible-plug nozzle flow is highly three dimensional and characterized by internal flow separation and shock effects. The resultant thrust and discharge coefficient levels were lower than previous wedge nozzle results. In addition, increasing shroud internal angle increased resultant thrust ratio but decreased discharge coefficient. Increasing shroud length increased resultant thrust ratio performance for NPR's greater than 6.0 but for NPR's less than 6.0, resultant thrust ratio decreased as shroud length increased. Increasing plug length caused an increase in resultant thrust ratio and an increase in discharge coefficient. Increasing geometric yaw vector angle had no effect on resultant thrust ratio and little effect on discharge coefficient.

Cler, Daniel L.↗

Internal performance of Highly Integrated Deployable Exhaust Nozzles

The internal performance characteristics of Highly Integrated Deployable Exhaust Nozzles (HIDEN) applicable to advanced short take-off and vertical landing aircraft have been investigated. Four nozzle concepts, designed for fan and core flow installations, were tested with varying contraction ratio and nozzle exit plane shape. In addition, two offtake duct designs, along with several centerbody and blocker geometries were tested to evaluate their effect on the static thrust and flow performance. This investigation was conducted in the static test facility of the NASA Langley 16-Foot Transonic Tunnel. A six-component strain-gage balance collected force and moment data, and static pressure, total pressure, and total temperature measurements were also made internal to the model. Room temperature, dry high-pressure air was used to simulate jet exhaust. The results indicate that the internal performance of these HIDEN concepts is comparable to previously tested nozzle concepts designed for thrust vectoring about a bearing plane. This report presents the configuration design of the HIDEN concepts and the results of the internal performance testing.

Taylor, John G.↗

A static investigation of the thrust vectoring system of the F/A-18 high-alpha research vehicle

A static (wind-off) test was conducted in the static test facility of the Langley 16-foot Transonic Tunnel to evaluate the vectoring capability and isolated nozzle performance of the proposed thrust vectoring system of the F/A-18 high alpha research vehicle (HARV). The thrust vectoring system consisted of three asymmetrically spaced vanes installed externally on a single test nozzle. Two nozzle configurations were tested: A maximum afterburner-power nozzle and a military-power nozzle. Vane size and vane actuation geometry were investigated, and an extensive matrix of vane deflection angles was tested. The nozzle pressure ratios ranged from two to six. The results indicate that the three vane system can successfully generate multiaxis (pitch and yaw) thrust vectoring. However, large resultant vector angles incurred large thrust losses. Resultant vector angles were always lower than the vane deflection angles. The maximum thrust vectoring angles achieved for the military-power nozzle were larger than the angles achieved for the maximum afterburner-power nozzle.

Mason, Mary L.↗

Multiaxis thrust vectoring using axisymmetric nozzles and postexit vanes on an F/A-18 configuration vehicle

A ground-based investigation was conducted on an operational system of multiaxis thrust vectoring using postexit vanes around an axisymmetric nozzle. This thrust vectoring system will be tested on the NASA F/A-18 High Alpha Research Vehicle (HARV) aircraft. The system provides thrust vectoring capability in both pitch and yaw. Ground based data were gathered from two separate tests at NASA Langley Research Center. The first was a static test in the 16-foot Transonic Tunnel Cold-Jet Facility with a 14.25 percent scale model of the axisymmetric nozzle and the postexit vanes. The second test was conducted in the 30 by 60 foot wind tunnel with a 16 percent F/A-18 complete configuration model. Data from the two sets are being used to develop models of jet plume deflection and thrust loss as a function of vane deflection. In addition, an aerodynamic interaction model based on plume deflection angles will be developed. Results from the scale model nozzle test showed that increased vane deflection caused exhaust plume turning. Aerodynamic interaction effects consisted primarily of favorable interaction of moments and unfavorable interaction of forces caused by the vectored jet plume.

Bowers, Albion H.↗

External nozzle flap dynamic load measurements on F-15 S/MTD model

Dynamic pressure loads were obtained on 1/12 scale models of the F-15B production aircraft and the F-15 S/MTD experimental aircraft with rectangular nozzles and canards. Flight Mach numbers from 0.51 to 1.20 were studied for aircraft angles of attack from 0 to 10 deg and nozzle pressure ratios from 1.00 to 5.09. The results show that dynamic levels are lower in the internozzle region of twin rectangular nozzles than are levels found with twin axisymmetric nozzles. At other locations, the levels associated with both geometries are of the same order of magnitude when normalized by aircraft dynamic Q. At Mach number of 0.51, the loads spectrum is dominated by plume shock noise processes for both geometries. Above Mach 0.51, this mechanism is associated with either vortex bursting from a forward location or turbulent boundary layer separation over the nozzle external flaps. At supersonic speeds both geometries show significantly decreased load levels.

Seiner, John M.↗

An experimental investigation of thrust vectoring two-dimensional convergent-divergent nozzles installed in a twin-engine fighter model at high angles of attack

An investigation was conducted in the Langley 16-Foot Transonic Tunnel to determine thrust vectoring capability of subscale 2-D convergent-divergent exhaust nozzles installed on a twin engine general research fighter model. Pitch thrust vectoring was accomplished by downward rotation of nozzle upper and lower flaps. The effects of nozzle sidewall cutback were studied for both unvectored and pitch vectored nozzles. A single cutback sidewall was employed for yaw thrust vectoring. This investigation was conducted at Mach numbers ranging from 0 to 1.20 and at angles of attack from -2 to 35 deg. High pressure air was used to simulate jet exhaust and provide values of nozzle pressure ratio up to 9.

Capone, Francis J.↗

Transonic Navier-Stokes solutions of three-dimensional afterbody flows

The performance of a three-dimensional Navier-Stokes solution technique in predicting the transonic flow past a nonaxisymmetric nozzle was investigated. The investigation was conducted at free-stream Mach numbers ranging from 0.60 to 0.94 and an angle of attack of 0 degrees. The numerical solution procedure employs the three-dimensional, unsteady, Reynolds-averaged Navier-Stokes equations written in strong conservation form, a thin layer assumption, and the Baldwin-Lomax turbulence model. The equations are solved by using the finite-volume principle in conjunction with an approximately factored upwind-biased numerical algorithm. In the numerical procedure, the jet exhaust is represented by a solid sting. Wind-tunnel data with the jet exhaust simulated by high pressure air were also obtained to compare with the numerical calculations.

Compton, William B., III↗

Static performance of an axisymmetric nozzle with post-exit vanes for multiaxis thrust vectoring

An investigation was conducted in the static test facility of the Langley 16-Foot Transonic Tunnel to determine the flow-turning capability and the nozzle internal performance of an axisymmetric convergent-divergent nozzle with post-exit vanes installed for multiaxis thrust vectoring. The effects of vane curvature, vane location relative to the nozzle exit, number of vanes, and vane deflection angle were determined. A comparison of the post-exit-vane thrust-vectoring concept with other thrust-vectoring concepts is provided. All tests were conducted with no external flow, and nozzle pressure ratio was varied from 1.6 to 6.0.

Berrier, Bobby L.↗

Static performance of nonaxisymmetric nozzles with yaw thrust-vectoring vanes

A static test was conducted in the static test facility of the Langley 16 ft Transonic Tunnel to evaluate the effects of post exit vane vectoring on nonaxisymmetric nozzles. Three baseline nozzles were tested: an unvectored two dimensional convergent nozzle, an unvectored two dimensional convergent-divergent nozzle, and a pitch vectored two dimensional convergent-divergent nozzle. Each nozzle geometry was tested with 3 exit aspect ratios (exit width divided by exit height) of 1.5, 2.5 and 4.0. Two post exit yaw vanes were externally mounted on the nozzle sidewalls at the nozzle exit to generate yaw thrust vectoring. Vane deflection angle (0, -20 and -30 deg), vane planform and vane curvature were varied during the test. Results indicate that the post exit vane concept produced resultant yaw vector angles which were always smaller than the geometric yaw vector angle. Losses in resultant thrust ratio increased with the magnitude of resultant yaw vector angle. The widest post exit vane produced the largest degree of flow turning, but vane curvature had little effect on thrust vectoring. Pitch vectoring was independent of yaw vectoring, indicating that multiaxis thrust vectoring is feasible for the nozzle concepts tested.

Mason, Mary L.↗

Effect of varying internal geometry on the static performance of rectangular thrust-reverser ports

An investigation has been conducted to evaluate the effects of several geometric parameters on the internal performance of rectangular thrust-reverser ports for nonaxisymmetric nozzles. Internal geometry was varied with a test apparatus which simulated a forward-flight nozzle with a single, fully deployed reverser port. The test apparatus was designed to simulate thrust reversal (conceptually) either in the convergent section of the nozzle or in the constant-area duct just upstream of the nozzle. The main geometric parameters investigated were port angle, port corner radius, port location, and internal flow blocker angle. For all reverser port geometries, the port opening had an aspect ratio (throat width to throat height) of 6.1 and had a constant passage area from the geometric port throat to the exit. Reverser-port internal performance and thrust-vector angles computed from force-balance measurements are presented.

Re, Richard J.↗

Static investigation of post-exit vanes for multiaxis thrust vectoring

Transonic wind tunnel tests are conducted to determine the flow-turning capabilities and nozzle internal performance of axisymmetric and nonaxisymmetric nozzles employing postexit vanes for multiaxis thrust-vectoring. The geometric parameters investigated for the axisymmetric nozzle installation were number of vanes, vane curvature, vane location relative to nozzle exit, and vane deflection angle; for the nonaxisymmetric cases, the parameters were vane planform and curvature, nozzle type, and nozzle exit aspect ratio. Nozzle pressure ratio was varied from 1.5 to 6.0, using high pressure air.

Berrier, Bobby L.↗

Multiaxis aircraft control power from thrust vectoring at high angles of attack

Extensive research programs conducted at the Langley Research Center have shown that thrust vectoring can be provided by multifunction (nonaxisymmetric) nozzles. Most of this research has been conducted on pitch vectoring at both static and forward flight conditions. Recent efforts have been aimed at evaluating yaw vectoring concepts at static (wind off) conditions. This paper summarizes results for three different twin-engine fighter configurations tested over a Mach number range of 0.15 to 2.47 at angles of attack up to 35 deg. The objective of these investigations was to determine the multiaxis control power characteristics provided by thrust vectoring. All three configurations employed two-dimensional convergent-divergent nozzles which provided pitch vectoring by differential deflection of the upper and lower nozzle divergent flaps. Three different means of yaw vectoring were tested: (1) a translating nozzle sidewall; (2) yaw flaps located in the nozzle sidewalls; and (3) canted nozzles. These investigations were conducted in the Langley 16-Foot Transonic Tunnel and the Lewis 10 x 10-Foot Supersonic Tunnel. Longitudinal and direction control power from thrust vectoring was greater than that provided by aerodynamic control effectors at low speed or at high angles of attack.

Capone, Francis J.↗