Search NASASearch

Engineering topics

Mason, P. V.

Publications and source records attributed to Mason, P. V..

At least 19 records

Analysis of Polarized Dust Emission Using Data from the First Flight of SPIDER

Using data from the first flight of Spider and from the Planck High Frequency Instrument, we probe the properties of polarized emission from interstellar dust in the Spider observing region. Component-separation algorithms operating in both the spatial and harmonic domains are applied to probe their consistency and to quantify modeling errors associated with their assumptions. Analyses of diffuse Galactic dust emission spanning the full Spider region demonstrate (i) a spectral energy distribution that is broadly consistent with a modified-blackbody (MBB) model with a spectral index of β d = 1.45 ± 0.05 (1.47 ± 0.06) for E (B)-mode polarization, slightly lower than that reported by Planck for the full sky; (ii) an angular power spectrum broadly consistent with a power law; and (iii) no significant detection of line-of-sight polarization decorrelation. Tests of several modeling uncertainties find only a modest impact (~10% in σ r ) on Spider's sensitivity to the cosmological tensor-to-scalar ratio. The size of the Spider region further allows for a statistically meaningful analysis of the variation in foreground properties within it. Assuming a fixed dust temperature T d = 19.6 K, an analysis of two independent subregions of that field results in inferred values of β d = 1.52 ± 0.06 and β d = 1.09 ± 0.09, which are inconsistent at the 3.9σ level. Furthermore, a joint analysis of Spider and Planck 217 and 353 GHz data within one subregion is inconsistent with a simple MBB at more than 3σ, assuming a common morphology of polarized dust emission over the full range of frequencies. This evidence of variation may inform the component-separation approaches of future cosmic microwave background polarization experiments.

79 ASTRONOMY AND ASTROPHYSICS

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic microwave background (CMB) polarimeters aspire to measure the faint B-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence, rotation of the polarization of the CMB arising from parity-violating physics, which would produce nonzero expectation values for the CMB's temperature to B-mode correlation (TB) and E-mode to B-mode correlation (EB) spectra. However, instrumental systematic effects can also cause these TB and EB correlations to be nonzero. In particular, an overall miscalibration of the polarization orientation of the detectors produces TB and EB spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the BB spectrum. We find that BICEP1 three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of alpha = −2.77deg +/- 0.86deg (statistical) +/- 1.3deg (systematic). We have revised the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We also account for the (negligible) impact of measured beam systematic effects. We investigate the polarization rotation for the BICEP1 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either of these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the TB and EB spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological B-mode spectrum from leaked E-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from r < 0.70 to r < 0.65 at 95% confidence.

three-year

Scientific Verification of Faraday Rotation Modulators: Detection of Diffuse Polarized Galactic Emission

The design and performance of a wide bandwidth linear polarization-modulator based on the Faraday effect is described. Faraday Rotation Modulators (FRMs) are solid-state polarization switches that are capable of modulation up to approx 10 kHz. Six FRMs were utilized during the 2006 observing season in the Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment; three FRMs were used at each of BICEP fs 100 and 150 GHz frequency bands. The technology was verified through high signal-to-noise detection of Galactic polarization using two of the six FRMs during four observing runs in 2006. The features exhibit strong agreement with BICEP fs measurements of the Galaxy using non-FRM pixels and with the Galactic polarization models. This marks the first detection of high signal-to-noise mm-wave celestial polarization using fast, active optical modulation. The performance of the FRMs during periods when they were not modulated was also analyzed and compared to results from BICEP fs 43 pixels without FRMs.

Moyerman, S.

Space Infrared Telescope Facility mission and cryogenic design

The Space Infrared Telescope Facility is the last of the Great Observatory missions. It is presently scheduled for launch in 2001. The mission will study the infrared spectrum from 2 to 1200 microns with three imaging and spectral instruments. The observatory will have a 5 year lifetime and will be placed in a 100,000 km earth orbit. The cryogenic system is based on a 4000 I superfluid helium cryostat. The mission and the cryogenic system are described, and the cryogenic technology issues are discussed.

Mason, P. V.

Third-sound propagation in thick films of superfluid He-4

Atkins' (1959) basic theory of third sound in thick films of superfluid He-4 is extended here to include a heat source for exciting third sound. A one-dimensional model obeying periodic boundary conditions is developed which can represent a variety of experimentally important configurations. General solutions for the model equations are found which give a complete description of third-sound waves in terms of displacement of the film surface, superfluid velocity, and temperature change as functions of space and time. Algebraic expressions for quantities that occur in general formulas are found for special excitation signals. The structure of third sound is calculated for the first time and the results are found to be inconsistent with previous findings. A direct method for accurately measuring the vaporization coefficient is also presented.

Jackson, H. W.

Long-term performance of the passive thermal control systems of the IRAS spacecraft

Degradation of passive thermal control systems in space is a matter of serious concern and has been observed in many missions. The performance of the passive thermal control systems of the Infrared Astronomical Satellite (IRAS) over a period of three years is reported here. An exterior temperature of 200 K and a sunshade temperature of approximately 100 K were maintained over this period without significant degradation. The temperature of the telescope contained in the IRAS cryostat was also observed for two years after expenditure of the helium cryogen. It remained at 100 K with no degradation.

Mason, P. V.

The Spacelab 2 superfluid helium experiment

An experiment to investigate the properties of superfluid helium in a microgravity environment flew on the Shuttle on the Spacelab 2 mission in July and August of 1985. This paper summarizes the flight experiment and describes the preliminary results. The experiment comprised an investigation of long-wavelength third-sound waves in micron-thick films, a study of the motions of superfluid helium under milli-g and micro-g accelerations, and measurements of the fluctuations in temperature associated with the small motions of the bulk helium. An additional accomplishment was to qualify and characterize a reflyable, space compatible cryostat.

Mason, P. V.

Preliminary results of the Spacelab 2 superfluid helium experiment

An experiment to investigate the properties of superfluid helium in a microgravity environment flew on the Shuttle on the Spacelab 2 mission in July and August of 1985. This paper summarizes the flight experiment and describes some preliminary results. The experiment comprised an investigation of long-wavelength third-sound waves in micron-thick films, a study of the motions of superfluid helium under milli-g and micro-g accelerations, and measurements of the fluctuations in temperature associated with the small motions of the bulk helium. An additional objective was to qualify and characterize a reflyable, space-compatible cryostat.

Mason, P. V.

IRAS cryogenic system flight performance report

It is pointed out that the Infrared Astronomical Satellite (IRAS) is the first telescope to perform observations in the far infrared from orbit. IRAS was launched on January 25, 1983 into a 900 km orbit. The use of the first large superfluid helium dewar in space makes it possible to provide a 2 K telescope environment for an anticipated period of one year. A description of the cryogenic system of IRAS is presented, taking into account the superfluid helium tank, the insulation system, the vacuum shell, the aperture cover, and the fluid management system. The dynamic performance of the cryogenic system is considered along with aspects of prelaunch preparations. Details of flight performance are also discussed, giving attention to transient performance, and steady state performance.

Urbach, A. R.

Infrared Astronomical Satellite (IRAS) superfluid helium tank temperature control

The infrared detectors on the Infrared Astronomical Satellite (IRAS), which was placed into a polar orbit in January 1983, are cooled to a temperature of less than 3 K by thermal coupling to the main cryogenic tank (MCT) containing superfluid helium. A porous plug built into the vent line entrance acts as a superfluid helium liquid/vapor separator in zero gravity. A description of the IRAS MCT flight porous plug is presented, and tests of the plug in situ are discussed, taking into account submerged plug tests, a restart test, and a cold vapor flow test. Aspects of flow rate determination in the case of an unavailability of flight flow rate data are also considered.

Petrac, D.

Helium hammer in superfluid transfer

Large transient pressure pulses, referred to as a helium hammer, which occurred in the transfer line of the main cryogenic tank during the development tests of the Infrared Astronomical Satellite, launched on January 25, 1983, are analyzed, and the measures taken to prevent a failure described. The modifications include an installation of a 2.3-liter surge tank upstream, and a back-up relief valve downstream, of a burst disk. The surge tank is designed to attenuate a 0.33-MPa pressure pulse at the inlet down to 0.092 MPa at the outlet. A mechanism of the pulse generation is suggested, which involves flashing and rapid recondensation of the small amount of liquid entering the warm section of a transition to room temperature.

Tward, E.

Damping of thermoacoustic oscillations

A commonly encountered and troublesome problem in cryogenic systems is related to the occurrence of thermoacoustic oscillations (TAO). The oscillations are accompanied by large heat fluxes which can cause large increases in the boiloff from dewars. Such a boiloff can lead to a serious degradation in performance. It appears, therefore, highly advisable to incorporate mechanisms for damping TAO in those parts of the system where there oscillations might occur. The present investigation is concerned with the criteria for the design of such damping mechanisms. Attention is given to the theory regrading the suppression of TAO, a damper consisting of a capillary with a surge tank, and porous solid dampers.

Tward, E.

Progress report on the infrared astronomical satellite cryogenic system

The main cryogen tank is sized to hold 70 kg of superfluid helium with 12 percent ullage at a temperature of 1.8 K. The insulation system surrounds the main cryogen tank with four blankets of multilayer insulation spaced by means of three vapor-cooled shields. It is noted that the multilayer insulation is 6.4 micron double-aluminized Mylar separated by polyester net. The main shell provides the primary structural integrity of the system. In orbit the main shell is cooled to 170 K using insulation blankets on one side and second surface paint on the opposite side. The aperture cover subassembly is the vacuum seal for the main shell during operation on the ground. It is also a gas condensation trap before and during cooldown of the main cryogen tank during launch hold. It contains 6 kg of supercritical helium, which permits 14 days on orbit with a 48-hour launch pad hold.

Urbach, A. R.

Dynamics of superfluid helium in zero gravity

The Spacelab 2 superfluid helium experiment was designed to: (1) examine the behavior of capillary waves and measure their velocity and dampling; (2) study the sloshing motion of bulk superfluid helium in near-zero gravity in order to determine its effects on sensors and attitude control systems for far infrared telescopes; and (3) determine the temperature distributions in the liquid and their correlation with bulk motion. The experiment system includes a helium cryostat with a sensor head and a microcomputer to provide electrical excitation and gather and transmit resultant responses to the experiment teams on the ground. Astronaut intervention is possible.

Mason, P. V.