Search NASA⌕ Search

Engineering topics

Masters, N.

Publications and source records attributed to Masters, N..

Time-resolved X-ray diffraction diagnostic development for the National Ignition Facility

Here we present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 10 11 , 10.25-keV photons/ns at the 400 μm diameter sample.

36 MATERIALS SCIENCE↗

Developing a platform for Fresnel diffractive radiography with 1 μ m spatial resolution at the National Ignition Facility

An x-ray Fresnel diffractive radiography platform was designed for use at the National Ignition Facility. It will enable measurements of micron-scale changes in the density gradients across an interface between isochorically heated warm dense matter materials, the evolution of which is driven primarily through thermal conductivity and mutual diffusion. Here we use 4.75 keV Ti K-shell x-ray emission to heat a 1000 μm diameter plastic cylinder, with a central 30 μm diameter channel filled with liquid D 2 , up to 8 eV. This leads to a cylindrical implosion of the liquid D 2 column, compressing it to ~2.3 g/cm 3 . After pressure equilibration, the location of the D 2 /plastic interface remains steady for several nanoseconds, which enables us to track density gradient changes across the material interface with high precision. For radiography, we use Cu He- α x rays at 8.3 keV. Using a slit aperture of only 1 μm width increases the spatial coherence of the source, giving rise to significant diffraction features in the radiography signal, in addition to the refraction enhancement, which further increases its sensitivity to density scale length changes at the D 2 /plastic interface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

Increased Ion Temperature and Neutron Yield Observed in Magnetized Indirectly Driven $\mathrm{D_2}$-Filled Capsule Implosions on the National Ignition Facility

Here, the application of an external 26 Tesla axial magnetic field to a D 2 gas-filled capsule indirectly driven on the National Ignition Facility is observed to increase the ion temperature by 40% and the neutron yield by a factor of 3.2 in a hot spot with areal density and temperature approaching what is required for fusion ignition. The improvements are determined from energy spectral measurements of the 2.45 MeV neutrons from the D(d, n) 3 He reaction, and the compressed central core B field is estimated to be ~4.9 kT using the 14.1 MeV secondary neutrons from the D(T, n) 4 He reactions. The experiments use a 30 kV pulsed-power system to deliver a ~ 3 μs current pulse to a solenoidal coil wrapped around a novel high-electrical-resistivity AuTa 4 hohlraum. Radiation magnetohydrodynamic simulations are consistent with the experiment

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 2–4 keV multilayer mirrored channel for the NIF Dante system

During inertial confinement fusion experiments at the National Ignition Facility (NIF), a capsule filled with deuterium and tritium (DT) gas, surrounded by a DT ice layer and a high-density carbon ablator, is driven to the temperature and densities required to initiate fusion. In the indirect method, 2 MJ of NIF laser light heats the inside of a gold hohlraum to a radiation temperature of 300 eV; thermal x rays from the hohlraum interior couple to the capsule and create a central hotspot at tens of millions degrees Kelvin and a density of 100–200 g/cm3. During the laser interaction with the gold wall, m-band x rays are produced at ∼2.5 keV; these can penetrate into the capsule and preheat the ablator and DT fuel. Preheat can impact instability growth rates in the ablation front and at the fuel–ablator interface. Monitoring the hohlraum x-ray spectrum throughout the implosion is, therefore, critical; for this purpose, a Multilayer Mirror (MLM) with flat response in the 2–4 keV range has been installed in the NIF 37° Dante calorimeter. Precision engineering and x-ray calibration of components mean the channel will report 2–4 keV spectral power with an uncertainty of ±8.7%.

Rubery, M. S. (ORCID:0000000344152818)↗

High-yield magnetic recoil neutron spectrometer on the National Ignition Facility for operation up to 60 MJ

We report that recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 x 10 17 , places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (T ion ), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 x 10 17 , and yield and T ion up to 2 x 10 18 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 x 10 19 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10x but also improve signal-to-background by 5x.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Magnetized Indirect Drive Project on the National Ignition Facility

A new project is underway at the National Ignition Facility with the goal of applying a seed magnetic field to the fusion fuel in an indirect drive hohlraum implosion and quantifying the effect on the hot-spot temperature, shape and neutron yield. Magnetizing fusion fuel is calculated to reduce heat loss from the implosion core by constraining the motion of electrons and fusion-generated alpha particles; this can improve the chances of achieving high-gain fusion in a laboratory plasma. Here, we describe the goals of this project and the significant scientific and technological challenges which must be overcome for this project to succeed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long duration x-ray source development for x-ray diffraction at the National Ignition Facility

We present the results of experiments to produce a 10 ns-long, quasi-monochromatic x-ray source. This effort is needed to support time-resolved x-ray diffraction (XRDt) measurements of phase transitions during laser-driven dynamic compression experiments at the National Ignition Facility. To record XRDt of phase transitions as they occur, we use high-speed (∼1 ns) gated hybrid CMOS detectors, which record multiple frames of data over a timescale of a few to tens of ns. Consequently, to make effective use of these imagers, XRDt needs the x-ray source to be narrow in energy and uniform in time as long as the sensors are active. The x-ray source is produced by a laser irradiated Ge foil. Our results indicate that the x-ray source lasts during the whole duration of the main laser pulse. Both time-resolved and time-integrated spectral data indicate that the line emission is dominated by the He-α complex over higher energy emission lines. Time-integrated spectra agree well with a one-dimensional Cartesian simulation using HYDRA that predicts a conversion efficiency of 0.56% when the incident intensity is 2 × 1015 W/cm2 on a Ge backlighter.

Werellapatha, K. (ORCID:0000000293154054)↗

Using time-resolved penumbral imaging to measure low hot spot x-ray emission signals from capsule implosions at the National Ignition Facility

Here, we have developed and fielded a new x-ray pinhole-imaging snout that exploits time-resolved penumbral imaging of low-emission hot spots in capsule implosion experiments at the National Ignition Facility (NIF). We report on results for a series of indirectly driven Be capsule implosions that aim at measuring x-ray Thomson scattering (XRTS) spectra at extreme density conditions near stagnation. In these implosions, x-ray emission at stagnation is reduced by 100 – 1000x compared to standard inertial confinement fusion (ICF) implosions to mitigate undesired continuum background in the XRTS spectra. Our snout design enables not only measurements of peak x-ray emission times, t o , where standard ICF diagnostics would not record any signal, but also allows for inference of hot spots shapes. Measurement of t o is crucial to account for shot-to-shot variations in implosion velocity and therefore to benchmark the achieved plasma conditions between shots and against radiation hydrodynamics simulations. Additionally, we used differential filtering to infer a hot spot temperature of 520 ± 80 eV, which is in good agreement with predictions from radiation hydrodynamic simulations. Here, we find that, despite fluctuations of the x-ray flash intensity of up to 5x, the emission time history is similar from shot to shot, and slightly asymmetric with respect to peak x-ray emission.

47 OTHER INSTRUMENTATION↗

Short pulse, high resolution, backlighters for point projection high-energy radiography at the National Ignition Facility

High-resolution, high-energy X-ray backlighters are very active area of research for radiography experiments at the National Ignition Facility (NIF) [Miller et al., Nucl. Fusion 44, S228 (2004)], in particular those aiming at obtaining Compton-scattering produced radiographs from the cold, dense fuel surrounding the hot spot. We report on experiments to generate and characterize point-projection-geometry backlighters using short pulses from the advanced radiographic capability (ARC) [Crane et al., J. Phys. 244, 032003 (2010); Di Nicola et al., Proc. SPIE 2015, 93450I-12], at the NIF, focused on Au micro-wires. We show the first hard X-ray radiographs, at photon energies exceeding 60 keV, of static objects obtained with 30 ps-long ARC laser pulses, and the measurements of strength of the X-ray emission, the pulse duration and the source size of the Au micro-wire backlighters. For the latter, a novel technique has been developed and successfully applied.

42 ENGINEERING↗

Resolving hot spot microstructure using x-ray penumbral imaging (invited)

We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arbitrary Lagrangian Eulerian Adaptive Mesh Refinement

This is a simulation code involving an ALE (arbitrary Lagrangian-Eulerian) hydrocode with AMR (adaptive mesh refinement) and pluggable physics packages for material strength, heat conduction, radiation diffusion, and laser ray tracing developed a LLNL, UCSD, and Berkeley Lab. The code is an extension of the open source SAMRAI (Structured Adaptive Mesh Refinement Application Interface) code/library. The code can be used in laser facilities such as the National Ignition Facility. The code is alsi being applied to slurry flow (landslides).

Koniges, A.↗