Search NASA⌕ Search

Engineering topics

Matam, Manjunath

Publications and source records attributed to Matam, Manjunath.

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.

array↗

Quantifying and Valuing Fundamental Characteristics and Benefits of Floating PV Systems

This project undertook the first systematic and comprehensive collection of Floating Photovoltaic (FPV) related techno-ecological data across diverse geographic regions of the United States. It examined FPV performance, assessed potential environmental risks and benefits, and provided data to support the development of research protocols for better understanding the impacts of FPV. As part of this process, we conducted a detailed study of four existing FPV sites and three land-based PV (LPV) sites in Florida and California.

14 SOLAR ENERGY↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months. Index Terms - photovoltaic module, floating PV systems, string, array, temperature, mismatch, utility scale.

ENGINEERING,SOLAR ENERGY↗

Review of Potential–Induced Degradation in Bifacial Photovoltaic Modules

Bifacial modules are increasingly deployed in the field and are expected to represent half of the market share within 10 years. Their rear structure differs from monofacial modules to allow additional light absorption. However, it brings new reliability challenges to address. In particular, the risk of potential-induced degradation (PID) is increased as both module sides are impacted. Different PID processes have been identified in the literature: shunting type (PID-s), polarization type (PID-p), Na penetration type, and corrosion type (PID-c). Their occurrence depends on the photovoltaic system configuration as well as the module's materials. Apart from PID-s, PID processes are not well understood and extensive research is needed to elucidate the PID scenario and underlying mechanisms. Herein, current knowledge about PID processes and their impact on the main bifacial modules in the market are gathered with the aim to guide future research. Bifacial module technologies and leakage current paths leading to PID are described. Indoor and outdoor PID testing methods are detailed. For each bifacial module technology, the PID processes are investigated with their indicators, mechanism and recovery process. Furthermore, PID-impacting factors and limitation solutions are finally reported and a state of the art on PID modeling is presented.

14 SOLAR ENERGY↗

High-Resolution Floating Solar PV Data

This dataset contains over two years of 1-minute resolution data collected from four floating solar sites, as well as data from a land-based PV system co-located with one of the floating sites. The dataset includes highly granular module temperature measurements - five modules per floating site, with three sensors per module, totaling 15 module temperature sensors per floating site. In addition to the module temperature data, meteorological data collected at the floating sites is also included, along with traditional PV system-level parameters. The data is intended for analysis of solar energy production, efficiency, and performance degradation over time. For information about the data file usage see the "README" resource below. See "Metadata File" for information about individual files and other metadata information.

Array↗

Mismatch losses in a PV system due to shortened strings

Numerous events may require intentional removal of one or more photovoltaic modules from a string, shortening the length of the string relative to others within the array, resulting in a string length mismatch. The impact of such a mismatch is not well understood either in measurable operational effects (voltage, current, power) or in the potential effects on long-term module health. It is impractical to solely approach this problem experimentally due to the size and complexity of arrays that may experience string length shortening. Here this work presents simulations, validated through limited field experiments on a two string array, providing a basis from which more complex arrays and scenarios may be explored. Refinement of the simulation achieves an overall error in IMPP for the nominal (S 1 ) and test strings (S 2 ) between the simulation and experimental values, through all test conditions, of +0.35 ± 1.46% and -0.36 ± 1.58% respectively. Shortening one of two strings by one module results in a power loss greater than the power contribution of the module alone (1.29 module equivalents); the impact increases through the maximum test case of a six module mismatch with a power loss equivalent to more than 11 modules. The impact of using string-end blocking diodes is presented with an emphasis at the array maximum power point and at open circuit. Implications are discussed for arrays of higher complexity.

14 SOLAR ENERGY↗