Improvement of the intrinsic time resolving power of the Cologne iron-free orange type electron spectrometers

Conversion electron spectroscopy represents an important tool for nuclear structure analysis of medium and heavy nuclei. Two iron-free magnetic electron spectrometers of the orange type have been installed at the Institute for Nuclear Physics of the University of Cologne. The very large transmission of 15% and the very good energy resolution of 1% makes the iron-free orange spectrometer a powerful instrument. By means of fast timing techniques, lifetimes of nuclear excited states can be measured with an accuracy better than 20 ps. For the first time, the energy dependent centroid position of prompt events yielding the time-walk characteristics (the prompt curve) of the orange spectrometer fast timing setup has been measured using prompt secondary {delta}-electrons generated in a pulsed beam experiment. The prompt curve calibrated as a function of energy allows precise lifetime determination down to a few tens of picoseconds by the use of the centroid shift method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear structure analysis using the Orange Spectrometer

Recently, an Orange spectrometer, a focusing iron-free magnetic spectrometer, has been installed at a beam line of the 10 MV Tandem accelerator of the IKP of the University of Cologne. The high efficiency of 15% of 4{pi} for the detection of conversion electrons and the energy resolution of 1% makes the Orange spectrometer a powerful instrument. From the conversion electron spectrum, transition multipolarities can be determined using the so called K to L ratio. In combination with an array of germanium and lanthanum bromide detectors, e{sup -}-{gamma}-coincidences can be performed to investigate the level scheme. Moreover, the very fast lanthanum bromide scintillator with an energy resolution of 3% allows e{sup -}-{gamma} lifetime measurements down to 0.3 ns. A second Orange spectrometer can be added to build the Double Orange Spectrometer for e{sup -}-e{sup -}-coincidences. It is indispensable for lifetime measurements of low intensity or nearby lying transitions as often occur in odd-A and odd-odd nuclei. The capabilities are illustrated with several examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Isomers in Fission Fragments

The structure of neutron-rich nuclei produced as secondary fission fragments was investigated using the EUROGAM and GAMMASPHERE ACS arrays, the LOHENGRIN fission-fragment mass separator and the FIFI fission-fragment identifier. Fission products were populated in spontaneous fission of {sup 248}Cm and {sup 252}Cf and in thermal neutron-induced fission of {sup 233}U, {sup 235}U and {sup 241}Pu at ILL Grenoble. Particularly useful in such studies are isomeric states, well populated in fission due to their yrast character, easy to detect due to their long half lives and easy to interpret because of their relatively simple composition. We discuss their role in studies of neutron-rich nuclei, giving examples of isomers found in our recent experiments. A special type of K-isomers, resulting from 'crossing' of extruder and intruder orbitals plays a role in the mechanism of a sudden onset of deformation in the A = 100 and A = 150 regions. We present evidence for these isomers in both regions. Possible further studies in this field are proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗