Search NASA⌕ Search

Engineering topics

Mathew, Paul

Publications and source records attributed to Mathew, Paul.

At least 37 records · Page 2

R&D and Implementation Outcomes from the U.S.-India Bilateral Center for Building Energy Research and Development Program

This paper explores the role of international partnerships to facilitate low-energy building design, construction, and operations. We present the strategic approach, joint research and development outcomes, and implementation activities of a unique U.S.-India program on buildings energy efficiency, the Center for Building Energy Research and Development. We discuss the collaboration successes in both countries despite their dissimilar building contexts, implementation challenges and opportunities. We highlight a range of R&D outcomes, such as novel tools and technologies developed and tested by the joint teams, with their technical energy savings potential, as well as results of capacity building and technology demonstrations. A deep-dive into key new scientific methods around building energy monitoring and benchmarking that could have a significant impact on high-performance of buildings in both countries is also provided. Finally, in addition to joint R&D successes, pathways to deployment, and lessons learned are discussed as key takeaways.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and the Real Estate Lifecycle: Stakeholder Perspectives

This report characterizes opportunities and pitfalls for leveraging key building lifecycle “events” as intervention points to enhance energy efficiency in real estate portfolios. It is based primarily on 33 interviews conducted with key industry stakeholders, including commercial real estate owners, operators, tenants, investors, developers, vendors, architecture/engineering firms, and construction managers. We focus on the following key events in the real estate life cycle because they are likely to present an opportunity for energy efficiency improvements: a) purchase or sale of a property; b) renovation; c) major equipment replacement; d) lease turnover or renewal; and e) refinancing. The stakeholder interviews covered business roles and processes, priorities, and sensitivities in these commercial real estate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComEd – LBNL ‘Beyond Widgets’ Project Automated Shading Integrated with Lighting and HVAC Controls: System Program Manual

This program manual contains detailed technical information for developing an incentive program for automated shading integrated with lighting and HVAC controls. The manual was developed by Lawrence Berkeley National Laboratory, in collaboration with ComEd as a partner in the ‘Beyond Widgets’ project funded by the U.S. Department of Energy Building Technologies Office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Cost Savings of Systems-Based Building Retrofits: A Study of Three Integrated Lighting Systems in Comparison with Component Based Retrofits

Most building retrofit projects are still component-based in that they typically address only one piece or type of equipment at a time. Systems-based retrofits that seek to address multiple components in an integrated manner have the potential to provide significantly greater energy savings. Lawrence Berkeley National Laboratory (LBNL) partnered with several utilities to develop and evaluate three different integrated retrofit packages involving lighting systems: automated shading with daylight dimming controls, workstation-specific lighting with daylight controls, and task/ambient lighting with plug load occupancy controls. Specifically, our analysis sought to quantify the marginal benefits of these systems (energy savings as well as lighting performance and visual comfort) relative to component based approaches. The analysis was based on a combination of measured performance data from LBNL’s FLEXLAB® test facility and energy simulations. All three systems were compared to a simple fluorescent-to-LED retrofit, which represents the component-based approach. While the simple LED upgrade provides significant lighting energy savings of 63%, the systems yielded energy savings of 81-93%, which equates to additional savings of 49-82% over the simple LED upgrade. All systems tested provided satisfactory visual comfort as well, indicating good potential for market acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raising the Rent Premium: Moving Green Building Research Beyond Certifications and Rent

Advocates for high-performing, energy efficient buildings understand the hurdles to proving the business case to spur development and investment decisions among commercial real estate owners and investors. Although there is significant evidence that green buildings exhibit increased financial performance via decreased operating expenses and non-energy benefits such as workplace comfort and employee productivity, green building practitioners still face an uphill battle when asked to prove the profits, most frequently pointing to rent premium as an indicator to attract investment. This paper documents a recently conducted literature review commissioned by the US Department of Energy (DOE) of 39 peer-reviewed and published academic papers pertaining to green or energy-related building attributes and financial performance. The review (first published here) indicated that 27 papers found a positive correlation between green building certifications and rents. If this is the case, then why are green building development and energy efficiency retrofits not the norm for the industry? This paper first synthesizes the recent literature review to illustrate that the existing body of empirical evidence supports green building investment. Next, it describes a workshop of leading academics in real estate sustainability and finance who met in late 2017 to discuss gaps in green building research and assess data challenges in their fields. Insights synthesized the workshop were used to drive new DOE led research that can provide value and understanding to investors and builders of high performing buildings. Finally, the paper offers insights into why the market is not properly pricing building efficiency, with factors ranging from improper mitigation of risks associated with energy and lack of transparency and responsibility felt by building end users, and what further steps are needed to transform green building investment practices in the commercial real estate industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Widgets: Validated Systems Energy Savings and Utility Custom Incentive Program Systems Trends

Energy efficiency upgrades to buildings to date through avenues such as utility incentive programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Integrated building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings (Regnier et al. 2017) that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – energy savings assessments are inherently more complex and are not easily suited to the deemed measure model, and implementation of systems can be more disruptive. This paper presents the outcomes of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with ComEd, a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)), and Xcel Energy (CO, MN). Previous work described the potential for energy savings of these systems at the individual and market level, early test findings for the task-ambient lighting system, and described the work products to develop utility incentive programs (Regnier et al. 2016). This paper presents validated end use energy savings of all three systems showing energy savings of ~20% for automated shading combined with daylight dimming (does not include light fixture retrofit savings); 30-46% for task-ambient lighting systems combined with plug load occupancy controls, depending on technology package and office building size (no daylight dimming impacts); and ~94% in the south-façade daylit zone for workstation specific lighting systems with daylight dimming (including lighting retrofit and task tuning). Using a U.S. Department of Energy (DOE) reference building model (DOE 2018), this translates to whole building savings of 2-5% (large-medium commercial), 12-23% (large-small commercial), and 13-15% (medium-large commercial) for these systems respectively. Early findings from the utilities in deploying these systems through their incentive programs indicate that deployment methods such as direct install programs might be best suited for these integrated systems. Further, early findings from a scoping study across custom utility programs and federal retrofit programs indicate that component level retrofits are still prevalent even in these programs, pointing towards an opportunity for deeper energy savings deployment. High performance retrofit case studies demonstrate that deeper energy savings is possible through integrated approaches. Market stakeholder interviews indicate however that there is generally a low level of awareness of the potential for energy savings of these three integrated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Do energy costs really affect commercial mortgage default risk? New results and implications for energy efficiency investments [PowerPoint]

This paper presents new results on the link between energy factors and commercial mortgage default. First, we summarize results from an empirical analysis of the impact of source energy use intensity (EUI) and electricity prices on mortgage default. We used a unique data set that merges building-level energy use data from city benchmarking ordinances and financial data for commercial mortgages on the same buildings. We found that building source EUI and electricity price are statistically and economically associated with commercial mortgage defaults. Next, we present five case studies on the impact of energy use and price variations on default risk: three office buildings, a hotel, and a multi-family residential building. We use the empirical model coefficients to compute the default risk impacts due to variations in source EUI and electricity price over the course of the mortgage term. We found that variations in source EUI could raise or lower the default rates in these properties by between 5% and 40%, depending on the property type and geography. Electricity pricing has an even greater effect – roughly 60% change in default rate in the Denver area and nearly 90% in northern California. Finally, we propose an energy risk score that lenders can use to assess energy risk and inform mortgage terms. The score is being developed and piloted in collaboration with three mortgage lenders. We conclude with implications of this score as a market signal and mechanism for incentivizing energy efficiency investments through the commercial mortgage channel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Packaged scalable energy information systems for hotels

Purpose: Building energy information systems (EIS) are performance monitoring software, data acquisition hardware and communication systems used to store, analyze and display building energy data. Some $60bn are spent annually on wasted energy in the US buildings, and actions taken based on EIS data can enable operational energy savings of approximately 10 per cent in the US commercial sector (approximately two quads of primary energy). However, EIS adoption is low because of various technical and market challenges. This paper aims to provide technical specifications for standardized EIS packages that can help overcome barriers and accelerate scale. Design/methodology/approach: Here, a five-step approach was followed: identifying business drivers as key determinants for hotel sector-specific packages; addressing heterogeneity to develop standardized, tiered packages; determining performance metrics for key stakeholders; recommending streamlined data architecture; and developing visualization enabling insights and actions. Findings: Technical specifications for two tiers (entry and advanced) of EIS packages for hotels have been developed. EIS vendor, integrator and client organization’s facilities and IT staff have been considered as key stakeholders. Findings from six field demonstrations show benefits of cost-effectiveness, through reduced transactional, first and operational costs, scalability, by accommodating heterogeneity across the building sub-sector, simplicity, by integrating meters, gateways and software in the package and actionability in organizations, across various decision-making levels. Originality/value: Building owners and operators can use these specifications to ease procurement and installation of EIS in their facilities. EIS software vendors can use them to develop new product offerings for underserved sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Widgets -- Systems Incentive Programs for Utilities

Utility incentive programs remain one of the most significant means of deploying commercialized, but underutilized building technologies to scale. However, these programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – baseline energy use must be defined and measured; the metrics for energy and performance must be defined and tested against; in addition, system savings must be validated under well understood conditions. This paper presents a sample of findings of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with Xcel Energy (CO, MN), ComEd, and a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)). Furthermore, these program packages consist of system specifications, system performance, M&V protocols, streamlined assessment methods, market assessment and implementation guidance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of Building Data Frameworks across Countries: Lessons for India

The report outlines the initial explorations carried out by LBNL on available examples of energy data collection frameworks for buildings. Specifically, this monograph deals with European experience in the buildings sector, the US experience in the commercial buildings sector, and examples of data collection effort in Singapore and China to capture the Asian experience in the commercial sector. The review also provides a summary of the past efforts in India to collect and use commercial building energy data and its strengths and weaknesses. The overall aim of this activity is to help understand the use cases that drive the granularity of data being collected and the range of methodologies adopted for the data collection effort. This review is a key input and reference for developing a data collection framework for India, and also clarifies general thinking on the institutional structure that may be amenable for data collection effort to match the needs and requirements of commercial building sector in India.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Xcel Energy – LBNL ‘Beyond Widgets’ Project. Workstation Specific Lighting with Daylight Dimming Controls System Program Manual

This program manual was developed through a U.S. Department of Energy project to develop streamlined utility program approaches to the deployment of integrated systems in commercial offices. Integrated systems present deep opportunities for energy savings, however by nature these systems have additional levels of complexity and effort required for their design and energy savings assessment, which create barriers for utility incentive programs to develop streamlined cost effective incentive programs to capture these savings. This project worked with Xcel Energy in Colorado and Minnesota to select an integrated system and develop a streamlined approach to its deployment for small and large commercial offices. Xcel Energy worked with LBNL to select a workstation specific lighting system with daylight dimming controls, applied as a retrofit in commercial office spaces. Previous studies indicated a potential lighting annual energy savings of 28-63%, with an average of 47% for this system type, due to reduced fixture LPD and controls only, not including a full fixture replacement from a condition such as T8 to LED. Xcel also had a desire to incorporate this fixture replacement in their integrated system package, and as a result annual energy lighting savings are expected to be higher. FLEXLAB testing of the system for 500 lux minimum output conditions translated into a 94% annual energy savings for this system. Market analysis was developed for large and medium commercial office buildings in Xcel’s Minnesota and Colorado markets showing a potential for 48-295 and 120-672 GWh of energy savings potential for Colorado and Minnesota respectively. Total Resource Costs (TRC) vary by location and technology package used (enterprise versus non-enterprise lighting controls system), and vary from 0.29 to 1.27 and 0.06 and 0.44 for a Retrofit case, and 0.20 to 1.63 and 0.07 to 0.57 for a Replace on Burnout strategy for Colorado and Minnesota respectively. These results indicate good potential for demonstrating a strong technical and economic case for deployment of this system type in Xcel’s Colorado territory, while deployment in the Minnesota market may be advisable as well as part of a portfolio of programs, or as an effort to help shift the market into integrated systems deployment in general. It should be noted that the cost of avoided energy in both markets is significantly low ($0.07/kWh for Minnesota, $0.08/kWh for Colorado), and these TRC values would not be representative of deployment potential in other markets with higher utility rates. In addition, installation costs used for these systems may decrease with time, further enhancing their return on investment. Overall, workstation specific lighting systems with daylight dimming controls present a very strong potential for cost effective lighting energy savings, as demonstrated by the FLEXLAB test results and previous case studies. Further energy savings may be realized from the use of fixture-specific occupancy sensors as well, although this approach was not considered in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing the Laboratory Market

Laboratories are estimated to be 3-5 times more energy intensive than typical office buildings and offer significant opportunities for energy use reductions. Although energy intensity varies widely, laboratories are generally energy intensive due to ventilation requirements, the research instruments used, and other health and safety concerns. Because the requirements of laboratory facilities differ so dramatically from those of other buildings, a clear need exists for an initiative exclusively targeting these facilities. The building stock of laboratories in the United States span different economic sectors, include governmental and academic institution, and are often defined differently by different groups. Information on laboratory buildings is often limited to a small subsection of the total building stock making aggregate estimates of the total U.S. laboratories and their energy use challenging. Previous estimates of U.S. laboratory space vary widely owing to differences in how laboratories are defined and categorized. A 2006 report on fume hoods provided an estimate of 150,000 laboratories populating the U.S. based in part on interviews of industry experts, however, a 2009 analysis of the 2003 Commercial Buildings Energy Consumption Survey (CBECS) generated an estimate of only 9,000 laboratory buildings. This report draws on multiple data sources that have been evaluated to construct an understanding of U.S. laboratories across different sizes and markets segments. This 2016 analysis is an update to draft reports released in October and December 2016.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unlocking energy efficiency in small commercial buildings through mechanical contractors

Although buildings smaller than 4,645 m 2 account for nearly half of the energy used in U.S. commercial buildings, energy-efficiency programs to date have primarily focused on larger buildings. Stakeholder interviews conducted during a scoping study by Lawrence Berkeley National Laboratory (LBNL) indicated interest in energy efficiency from the small commercial building sector, provided solutions are simple and of low cost. To address this need, an energy management package (EMP) was developed to deliver energy management to small commercial buildings via HVAC contractors, because they already serve these clients and the transaction cost to market would be reduced. This energy-management approach is unique from, but often complementary to, conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Furthermore, this paper presents an overview of the EMP, the business model to deliver it, and preliminary demonstration findings from a pilot use of the EMP. Results from the pilot validated that contractors could deliver the EMP in 4–8 h per building per year and that energy savings of 3–5% are feasible through this approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Establishing a Commercial Buildings Energy Data Framework for India: A Comprehensive Look at Data Collection Approaches, Use Cases and Institutions

Enhancing energy efficiency of the commercial building stock is an important aspect of any national energy policy. Understanding how buildings use energy is critical to formulating any new policy that may impact energy use, underscoring the importance of credible data. Data enables informed decision making and good quality data is essential for policy makers to prioritize energy saving strategies and track implementation. Given the uniqueness of the buildings sector and challenges to collecting relevant energy data, this study characterizes various elements involved in pertinent data collection and management, with the specific focus on well-defined data requirements, appropriate methodologies and processes, feasible data collection mechanisms, and approaches to institutionalizing the collection process. This report starts with a comprehensive review of available examples of energy data collection frameworks for buildings across different countries. The review covers the U.S. experience in the commercial buildings sector, the European experience in the buildings sector and other data collection initiatives in Singapore and China to capture the more systematic efforts in Asia in the commercial sector. To provide context, the review includes a summary and status of disparate efforts in India to collect and use commercial building energy data. Using this review as a key input, the study developed a data collection framework for India with specific consideration to relevant use cases. Continuing with the framework for data collection, this study outlines the key performance indicators applicable to the use cases and their collection feasibility, as well as immediate priorities of the participating stakeholders. It also discusses potential considerations for data collection and the possible approaches for survey design. With the specific purpose of laying out the possible ways to structure and organize data collection institutionally, the study collates existing mechanisms to analyze building energy performance in India and opportunities for standardizing data collection. This report describes the existing capacities and resources for establishing an institutional framework for data collection, the legislation and mandates that support such activity, and identifies roles and responsibilities of the relevant ministries and organizations. Finally, the study presents conclusions and identifies two major data collection strategies within the existing legal framework.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Factors in Commercial Mortgages: Gaps and Opportunities

The commercial real estate mortgage market is enormous, with almost half a trillion dollars in deals originated in 2015. Relative to other energy efficiency financing mechanisms, very little attention has been paid to the potential of commercial mortgages as a channel for promoting energy efficiency investments. The valuation and underwriting elements of the business are largely driven by the “net operating income” (NOI) metric – essentially, rents minus expenses. While NOI ostensibly includes all expenses, energy factors are in several ways given short shrift in the underwriting process. This is particularly interesting when juxtaposed upon a not insignificant body of research revealing that there are in fact tangible benefits (such as higher valuations and lower vacancy and default rates) for energy-efficient and “green” commercial buildings. This scoping report characterizes the current status and potential interventions to promote greater inclusion of energy factors in the commercial mortgage process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

India Commercial Buildings Data Framework: A Summary of Potential Use Cases

This report details a potential set of use cases for India’s Commercial Buildings Data Framework. The use cases are aimed at enabling data-driven, evidence-based policy making and at transforming the market for energy efficiency in the building sector by facilitating the adoption of (1) superior energy-efficient building design and operation and maintenance practices, and (2) better specification and procurement of end-use equipment and systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S.– India Joint Center for Building Energy Research and Development (CBERD) Caring for the Energy Health of Healthcare Facilities

The U.S.-India Joint Center for Building Energy Research & Development (CBERD), created through the Partnership to Accelerate Clean Energy (PACE) agreement between the United States and India, is a research and development (R&D) center with over 30 institutional and industry partners from both nations. This five-year presidential initiative is jointly funded by the U.S. Department of Energy and the Government of India. CBERD aims to build upon a foundation of collaborative knowledge, tools, and technologies, and human capabilities that will increase development of high-performance buildings. To reach this goal, the R&D focuses on energy use reduction throughout the entire life cycle of buildings—i.e., design, construction, and operations. During the operations phase of buildings, even with best-practice energy-efficient design, actual energy use can be much higher than the design intent. Every day, much of the energy consumed by buildings serves no purpose (Roth et al. 2005). Building energy information systems (EIS) are commercially available systems that building owners and facility managers use to assess their building operations, measure, visualize, analyze, and report energy cost and consumption. Energy information systems can enable significant energy savings by tracking energy use, identifying consumption patterns, and benchmarking performance against similar buildings, thereby identifying improvement opportunities. The CBERD team has identified potential energy savings of approximately 2 quads of primary energy in the United States, while industry building energy audits in India have indicated potential energy savings of up to 30 percent in commercial buildings such as offices. Additionally, the CBERD team has identified healthcare facilities (e.g., hospitals, clinics), hotels, and offices as the three of the highest-growth sectors in India that have significant energy consumption, and that would benefit the most from implementation of EIS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Center Energy Practitioner (DCEP) Program

The main objective for the DCEP program is to raise the standards of those involved in energy assessments of data centers to accelerate energy savings. The program is driven by the fact that significant knowledge, training, and skills are required to perform accurate energy assessments. The program will raise the confidence level in energy assessments in data centers. For those who pass the exam, the program will recognize them as Data Center Energy Practitioners (DCEPs) by issuing a certificate. Hardware req.: PC, MAC; Software Req.: Windows; Related/Auxiliary software--MS Office; Type of files: executable modules, user guide; Documentation: e-user manual; Documentation: http://www.1.eere.energy.gov/industry/datacenters/ 12/10/15-New Documentation URL: https://datacenters.lbl.gov/dcep

Traber, Kim↗