Search NASA⌕ Search

Engineering topics

Mathur, B. S.

Publications and source records attributed to Mathur, B. S..

Precise T and F intercomparison via VLF phase measurements

Continuous phase recording of the 16kHz transmission from GBR (UK) are being made and published midday phase data of GBR are received regularly from laboratories in the US, FGR, and UK. The local time scale (UTC, India), at the National Physical Laboratory in New Delhi, and those at the foreign laboratories are intercompared using the VLF phase data. A major factor which limits the accuracy of long term comparison is the seasonal variation in the VLF over delay over long paths. By taking into account the seasonal delay variations in a semiempirical way, the accuracy of time and frequency comparisons can be improved. Over a one year period, accuracy of a few parts in 10 to the 14th power in frequency and 1 to 2 micron sec in time were obtained. The relative frequency offset difference between UTC, (India) and UTC (PTB, Germany) of (7.0 + or - 0.1) x 10 to the -13 power agrees well with that obtained in a satellite experiment.

Gupta, A. S.↗

Precise time and frequency intercomparison between NPL, India and PTB, Federal Republic of Germany via satellite symphonie-1

A time and frequency intercomparison experiment conducted using Earth stations in New Delhi, India and Raisting, FRG is described. The NPL clock was placed at New Delhi Earth Station and the Raisting Clock was calibrated with PTB/Primary standard via LORAN-C and travelling clocks. The random uncertainity of time comparisons, represented by two sample Allan Variance sigma (30 seconds), was less than 10 nanoseconds. The relative frequency difference between the NPL and Raisting Clocks, SNPL, RAIS, as measured over the 44 days period was found to be -15.7 x 10 to the -13th power. The relative frequency difference between PTB Primary Standard and Raisting Clock, SPTB, RAIS, during this period, was measured to be -22.8 x 10 to the -13th power. The relative frequency difference between NPL clock and PTB Primary Standard, SNPL, PTB, thus, is +7.1 x 10 to the -13th power. The clock rate (UTC, India) of +7.1 + or - 0.5 x 10 to the -13th power, agrees well with that obtained via VLF phase measurements over one year period and with USNO travelling clock time comparisons made in September, 1980.

Mathur, B. S.↗

Clock synchronisation experiment in India using symphonie satellite

A recent clock synchronization experiment between the National Physical Laboratory (NPL), New Delhi and Space Applications Center (SAC), Ahemedabad, in India via geostationary satellite symphonie 2, stationed at 49 E longitude, is reported. A two-way transmission using a microwave transponder considered to provide the greatest precision in synchronization of two remote clocks is described.

Somayajulu, Y. V.↗

A study of time dissemination via satellite in India

A simultaneous two way clock synchronization experiment between three Earth stations, was performed and improvements over the technique earlier attempted in which transmit/receive roles of the two stations were alternated at regular intervals, were studied. Time signals via two modes high frequency and satellite were critically monitored and analyzed. This time format was modified to include the additional information about time of the day in year, month, day, hour, minute and second as well as DUT1 in BCD code and was disseminated via the satellite. These signals were decoded, displayed and studied. Some preliminary work on time transfer via TV using direct satellite broadcast, was also conducted.

Mathur, B. S.↗