Search NASA⌕ Search

Engineering topics

Mathurin, Leanne

Publications and source records attributed to Mathurin, Leanne.

Characterizing The Mechanical Properties of Polyurethane Foams

The Department of Energy has many radioactive facilities that are on the path of deactivation and decommissioning (D and D). These facilities can sit cold and dark for many years before final disposition, and must be maintained to ensure no radiological release occurs in the interim. Improvements and additions to D and D tool sets can greatly: Save time and money, Reduce worker risk. Conventional fixatives widely used often take the form of paints or films that are not readily applicable to 3-dimensional void spaces. Foams are one promising platform that may offer solutions to a number of contaminated problem sets such as: Gloveboxes, Pipes, Tanks. SRNL is working to characterize various commercial foams that would encapsulate the interior volume of a given space and are capable of immobilizing any remaining contamination. One key performance metric of these foams is how well they will perform in an accident scenario. To this end, SRNL is researching the mechanical properties of these foams to ensure that the material can withstand the environment of application while maintaining structural integrity. ASTM standard E3191-18 served as a guiding document for this project, outlining the requirements that foaming fixatives used for the mitigation of radioactive contamination need to meet before being implemented. Objective: Quantification of the mechanical properties of 6 commercial polyurethane foams was performed using multiple ASTM standards to record measurements for: Compression testing: Flexible Foams, Force required to produce 50% compression, Rigid Foams, Compressive and apparent modulus, Point of 10% core deformation, The 'Zero Deformation' point, Compressive strength, Yield point. Tensile testing: Tensile strength, Tensile stress, Percent elongation. Experiment 1: An electromechanical compressive tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1621, each rigid foam was compressed at 10% of the measured thickness per minute until the sample was 13% of it's original thickness. Per ASTM D35/4, each flexible foam was pre-flexed twice to 80% original thickness at a rate of 250 mm/min, then compressed to 80% original thickness at a rate of 50 mm/min. Experiment 2: An electromechanical tensile tester (MTS Criterion Series 43) was used to evaluate 6 foams (4 flexible, 2 rigid). Per ASTM D1623, rigid foams were pulled apart at a rate of 1.27 mm/min until the sample broke. Per ASTM D35/4, flexible foams were pulled apart at a rate of 500 mm/min until the sample broke. The strongest material in both compression and tensile testing scenarios was found to be the rigid intumescent polyurethane Hilti foam. The experiments revealed that the Hilti foam in a tensile scenario had a peak stress value that was larger than the closest competitor by a factor of 2.3 and a compressive yield point that was larger than the closest competitor by a factor of 1.4, indicating that the Hilti foam is the best choice for implementation in mechanically harsh environments. The performance metrics measured can serve as a basis for future mechanical tests that would help set relevant ASTM standards (E3191) for intumescent polyurethane foams in fixating applications. Tests like surface adhesion, impact, and flame tests would serve as a better indicator as to how this material would perform in environmentally harsh scenarios often found in decommissioned nuclear facilities. Further tests of the foams' intumescent properties would also be important should these foams be implemented in environmentally harsh scenarios.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concoction and Appraisal of Radiation Hardened Polyurethane Foams for DOE Decontamination and Decommissioning (D and D) Operations

Since World War 2, a number of nuclear facilities have been relocating their nuclear waste to long term storage, or final disposition. These facilities face monumental challenges in cleaning up the fixated transferrable radioactive waste that is left in these facilities after initial cleaning operations have ended. SRNL has identified a solution that is utilizing two-part epoxy foams with heavy metal additives for fixating and shielding transferable radioactive material that has accumulated in non uniform volumes. The purpose of this experiment is to make a library of data of physical characteristics of each foam and additive combination that will have data concerning how the material cures and performs in different environments with varying temperatures and how it will act and perform after being irradiated. Materials Being Tested: - Foam iT 7FR, Foam iT 23FR, 3M Fire Barrier foam, and Hilti CP620 foam; - Additives Bi, Bi2O{sub 3}, Na{sub 2}WO{sub 3}, and WO{sub 3} at 12.5% and 25%. What's being investigated: - Expansion data from each foam; - Radiation shielding data for each foam combination; - Peak temperatures for each foam. Utilized a FLIR thermal camera to find peak temperature and time it took the foam to reach it. No noticeable difference in volume or weight after blank foam samples sat in the environmental chamber for 24 hours except the 3M foam at the extreme relative humidity of 90% highlighted above. The more additives used in the foam, the more they were able to shield. The foams begin to saturate around 100% wt% where more additive used will not increase the shielding capability of the foam. Similar thermal dispersion in blanks and in samples with Bi additive. Time taken to peak temperature is very similar between the two. Similar peak temperatures in blanks and in Bi samples. Hilti had slightly elevated temperatures. All foams maintained their physical properties post environmental chamber except the 3M foam. With the increased sponginess from the high relative humidity's, 3M may be disqualified for further testing if its mechanical properties also suffer. While curing all foams had their peak temperature occur between 40 deg. C and 70 deg. C except the Hilti which occurred above 90 deg. C with and without additive. With this information, no foams would be disqualified. After radiation shielding studies, it was found that IT 14 with Bismuth and Bismuth Oxide Additives provided the best shielding of Co-60 with over 9% attenuation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing The Mechanical Properties of Polyurethane Foams

The purpose is to determine the mechanical properties of polyurethane foams with the intent of using PU foams to fill large void asymmetrical volumes like a glovebox to fixate transferable radiological material. Testing the resiliency of foam technologies when exposed to physicals stressors will be done. Six COTS PU foams considered will be fabricated and tested (iT 7, iT 8, iT 14, iT 23, 3M Fire Barrier, and Hilti) with and without additives at 12.5% wt (Bi, WO{sub 3}, and Na{sub 2}WO{sub 3}). Polyurethanes (PU) are a special class of polymeric materials that have great potential in many applications. Used in automotive, biomedical, construction, and textiles industries. Sought after due to its versatility and superior properties. PU foams have become one of the most prominent PU-based products. Bench-scale testing by SRNL and FIU-ARC confirmed PU foam technology's superior capabilities: Cured in various and desired volumes; No samples generated heat above 90 deg. C during curing reaction; Incorporation of additives (Bi, WO{sub 3}, BiO{sub 3}, Na{sub 2}WO{sub 3}) led to the following shielding: 98% of Am-241, 16% of Cs-137, 9.5% of Co-60. Proved foams' resistance to thermal stressors: Foams lasted 2 hours of direct flame; Excellent thermal insulation; Maintained structural integrity; No smoke or flame propagation. Experiment 1: A tensile tester (MTS Criterion Series 43) will be utilize to evaluate various properties of different PU rigid and flexible foams with and without additives (at 12.5% wt) under tension at 1 mm/s. Experiment 2: A thermogravimetric analysis (TGA) and Dynamic Mechanical Analyzer (DMA) will be employed to determine PU foams' breakdown of physical properties while under a constant heat rate (10 C/min) and strain rate (1%) under a period of time. Foams with additives showed an increase in stiffness and durability during tensile testing with WO{sub 3} producing the best results for Foam iT 7. All the other foam samples showed similar trends. Glass transition temperature (Tg) range for Foam iT 7 with Na{sub 2}WO{sub 3} ranged from 120-150 C while Foam iT 7 blank Tg range was from 90-110 C with a difference of about 30 C showing improvement with addition of additives.

36 MATERIALS SCIENCE↗