ASX O-ring Life Testing Using a LAW High Bound Melter Feed Simulant (Final Report)

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is planning to utilize an Isolok sampler to sample the contents of the Low Activity Waste (LAW) and High Level Waste (HLW) Melter Feed Preparation Vessels (MFPV) as well as the contents of the LAW Concentrate Receipt Vessel (CRV). Over the course of testing, it has been recognized that the long term reliability of the o-ring seals in the Isolok sampler are an important component in sampling. The Isolok sampler will be collecting samples of melter feed that contain a high percentage of highly abrasive particles which can impact the life of the o-rings. Although o-ring life in normal service is typically several hundred thousand cycles (such as in the air cylinders and other non-abrasive environments), no data are available for the life of the o-ring seals in this abrasive environment. To address this concern, a Test Exception was issued to perform testing to determine whether the o-rings in an Isolok sampler will continue to function through one year of projected HLW MFPV sampler operation, or approximately 7,000 sampler piston cycles. This final report provides results of the o-ring testing that was performed with the ASX sampler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Composition Variability Testing Using High Bounding LAW Melter Feed Simulant

This report documents the results of the testing that was performed to fulfill the Low Activity Waste (LAW) pretreated waste and melter feed product qualification requirements for Chemical Composition during Production as described in the Immobilized Low Activity Waste (ILAW) Product Compliance Plan and the Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the LAW melter feed preparation process and the resulting ILAW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to adequately mix the LAW melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the content level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a 72.7% scaled down tank, 8 feet in diameter, which was used to represent the LAW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to that of the WTP tank. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using a simulant that represented the high bound of rheology for the LAW melter feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreated Waste and Melter Feed Composition Variability Testing Using HLW Simulants

This report documents the results of the testing that was performed to fulfill the High Level Waste (HLW) pretreated waste and melter feed product qualification requirements for chemical composition and product loading as described in the Immobilized High Level Waste (IHLW) Wasteform Compliance Plan and the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the melter feed preparation process and the resulting IHLW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize pretreated waste and the melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP HLW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated HLW prior to GFC addition and the HLW melter feed after GFC addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DM100 and DM1200 Melter Testing with High Waste Loading Glass Formulations for Hanford High-Aluminum HLW Streams (Test Plan)

This Test Plan describes work to support the development and testing of high waste loading glass formulations that achieve high glass melting rates for Hanford high aluminum high level waste (HLW). In particular, the present testing is designed to evaluate the effect of using low activity waste (LAW) waste streams as a source of sodium in place of chemical additives, sugar or cellulose as a reductant, boehmite as an aluminum source, and further enhancements to waste processing rate while meeting all processing and product quality requirements. The work will include preparation and characterization of crucible melts in support of subsequent DuraMelter 100 (DM100) tests designed to examine the effects of enhanced glass formulations, glass processing temperature, incorporation of the LAW waste stream as a sodium source, type of organic reductant, and feed solids content on waste processing rate and product quality. Also included is a confirmatory test on the HLW Pilot Melter (DM1200) with a composition selected from those tested on the DM100. This work builds on previous work performed at the Vitreous State Laboratory (VSL) for Department of Energy’s (DOE’s) Office of River Protection (ORP) to increase waste loading and processing rates for high-iron HLW waste streams as well as previous tests conducted for ORP on the same waste composition. This Test Plan is prepared in response to an ORP-supplied statement of work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radar Level Measurement in the Presence of Foam Using an LAW High Bound Pretreated Waste Simulant

During previous testing with LAW simulants, the radar level detector, installed in a scale WTP LAW CRV tank at the VSL, worked well when the tank was being mixed. However, if the agitator was stopped and foam was present on the surface, then the radar detector measured the distance to the top of the foam, not the liquid level beneath the foam. This finding has a significant impact on the WTP because if the foam is thick enough, this will cause a high-biased level reading which could affect the composition of the melter feed because too much GFCs would be added to the tank. To address the response of the radar level detector to foam, a Test Exception was issued to perform additional testing that would determine whether the radar level detector signal can be adjusted such that it can identify the foam and liquid levels and reliably operate in the presence of foam on the surface of the slurry. This final report provides results of the testing that was performed with the radar level detector in the presence of foam on the liquid surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pretreated Waste and Melter Feed Composition Variability Testing Using LAW Simulants

This report documents the results of the testing that was performed to fulfill the Low Activity Waste (LAW) pretreated waste and melter feed product qualification requirements for Chemical Composition during Production as described in the Immobilized Low Activity Waste (ILAW) Product Compliance Plan and the Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the LAW melter feed preparation process and the resulting ILAW glass composition. In part, this control depends on (1) the ability of the Concentrate Receipt Vessel (CRV) system to homogenize the pretreated LAW concentrate feed, provide representative sampling of the vessel contents, measure the content level over the vessel operating range, and uniformly transfer the vessel contents, and (2) the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize the LAW melter feed after addition of the glass forming chemicals (GFCs) and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP LAW CRV and the LAW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated LAW prior to GFC addition and the LAW melter feed after GFC additions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Small Scale Melter Testing of HLW Algorithm Glasses: Matrix 2 Tests

The principal objectives of the DM100 tests were to determine the effects of variations in feed composition on glass processing rates and melter conditions (off-gas characteristics, glass processing, foaming, cold cap, etc.) at constant bubbling rate. These variations represent bounding concentrations of aluminum, boron, chromium, manganese, silicon, sodium, potassium, lanthanum, titanium, zinc, zirconium, strontium, and lithium. In addition, samples from these tests were used to assess the effects on glass durability as a result of these changes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗