Search NASA⌕ Search

Engineering topics

Matsui, Tsutomu

Publications and source records attributed to Matsui, Tsutomu.

Direct Mapping of Polyclonal Epitopes in Serum by HDX-MS

Elucidating the interactions that drive antigen recognition is central to understanding antibody-mediated protection and is vital for the rational design of immunogens. Often, structural knowledge of epitopes targeted by antibodies is derived from isolated studies of monoclonal antibodies, for which numerous structural techniques exist. In contrast, there are very few approaches capable of mapping the full scope of antigen surfaces targeted by polyclonal sera through the course of a natural antibody response. Here, in this study, we develop an approach using immobilized antigen coupled to hydrogen/deuterium exchange with mass spectrometry (HDX-MS) to probe epitope targeting in the context of the fully native serum environment. Using the well-characterized Staphylococcal enterotoxin B (SEB) as a model system, we show that complex combinations of epitopes can be detected and subtle differences across different anti-sera can be discerned. This work reveals new insight into how neutralizing antibodies and antisera target SEB, and more importantly, establishes a novel method for directly mapping the epitope landscape of polyclonal sera.

antigens↗

Adaptable SEC‐SAXS data collection for higher quality structure analysis in solution

Abstract The two major challenges in synchrotron size‐exclusion chromatography coupled in‐line with small‐angle x‐ray scattering (SEC‐SAXS) experiments are the overlapping peaks in the elution profile and the fouling of radiation‐damaged materials on the walls of the sample cell. In recent years, many post‐experimental analyses techniques have been developed and applied to extract scattering profiles from these problematic SEC‐SAXS data. Here, we present three modes of data collection at the BioSAXS Beamline 4–2 of the Stanford Synchrotron Radiation Lightsource (SSRL BL4‐2). The first mode, the High‐Resolution mode, enables SEC‐SAXS data collection with excellent sample separation and virtually no additional peak broadening from the UHPLC UV detector to the x‐ray position by taking advantage of the low system dispersion of the UHPLC. The small bed volume of the analytical SEC column minimizes sample dilution in the column and facilitates data collection at higher sample concentrations with excellent sample economy equal to or even less than that of the conventional equilibrium SAXS method. Radiation damage problems during SEC‐SAXS data collection are evaded by additional cleaning of the sample cell after buffer data collection and avoidance of unnecessary exposures through the use of the x‐ray shutter control options, allowing sample data collection with a clean sample cell. Therefore, accurate background subtraction can be performed at a level equivalent to the conventional equilibrium SAXS method without requiring baseline correction, thereby leading to more reliable downstream structural analysis and quicker access to new science. The two other data collection modes, the High‐Throughput mode and the Co‐Flow mode, add agility to the planning and execution of experiments to efficiently achieve the user's scientific objectives at the SSRL BL4‐2.

Matsui, Tsutomu↗