Temperature-Control Apparatus For Hydrogen Maser

Thermal-control apparatus maintains hydrogen maser at nearly constant temperature during long-term operational test. Designed to maintain, in small cylindrical vacuum tank containing maser, nearly isothermal condition when test conducted in air. Provides approximation of more nearly isothermal condition expected to be maintained in intended application, in which maser operated in vacuum environment and losses of heat reduced further by multilayer reflective insulation.

Vessot, R. F. C.

Status of local oscillators for operating ultra-high resolution frequency discriminators as frequency standards

The operation of new improved frequency standards based on new ultra-high-resolution frequency discriminators requires high stability local, or 'flywheel' oscillators. We review the spectral density of phase fluctuations of existing flywheel oscillators and the related time domain frequency stability of new and proposed cryogenically cooled oscillators suitable for this application. Presently used devices include the quartz crystal oscillator, the room-temperature actively oscillating atomic hydrogen (H) maser, and the superconducting maser oscillator. Future devices include the cryogenic H-maser and other cryogenic devices using resonators of superconducting metal or solid crystalline sapphire. The relation of the phase spectral density of these devices to the characteristics of present and proposed frequency discriminators based on trapped cooled ions and cold atoms is discussed in terms of their operation as frequency standards.

Vessot, R. F. C.

Atomic hydrogen maser measurements with wall surfaces of carbon tetrafluoride

The principal objectives of the Smithsonian Astrophysical Observatory cold maser research programs are given. This work is aimed principally at understanding more about the interaction of hydrogen atoms with wall coatings of fluorinated ethylene propylene (Dupont Teflon FEP-120 co-polymer) and of carbon tetrafluoride (CE4). The principal measured quantity in these experiments is the wall shift of the maser's output frequency. The wall shift per atomic collision was calculated from the measured wall frequency shift. This assumes that the wall surface area is smooth on a molecular scale.

Vessot, R. F. C.

Performance data of US Naval Observatory VLG-11 hydrogen masers since September, 1983

In 1983, two VLC-11 masers were delivered to the U.S. Naval Observatory by the Smithsonian Astrophysical Observatory. Last year the short-term stability of these masers was reported and the effect of this short-term stability on timekeeping performance was examined. Since the date of installation, 13 September 1983, data on the masers' long-term performance have been accumulated. The Allan variance, agma(tau), of the relative frequency between the masers reaches a minimum of about 4 parts in 10 to the 16th power at averaging times 5,000 seconds and rises at longer averaging times due, at least partly, to systematic frequency drift. The systematic frequency drifts, expressed in units of fractional frequency difference per day are discussed.

Vessot, R. F. C.

Test of the principle of equivalence by a null gravitational red-shift experiment

A test of the Einstein equivalence principle (EEP) was performed by carrying out a 'null' gravitational red-shift experiment. The experiment compared the rates of a pair of hydrogen maser clocks with those of a set of three superconducting-cavity stabilized oscillator clocks as a function of the solar gravitational potential. If EEP were not valid, the relative rates could vary with potential. During the experiment, the solar potential in the laboratory varied approximately linearly at 3 parts in 10 to the 12th per day because of the earth's orbital motion, and diurnally with an amplitude of 3 parts in 10 to the 13th because of the earth's rotation. An upper limit on the relative frequency variation of 1.7 parts in 100 of the external potential was set. The accuracy was limited by the frequency stability of the clocks and by unmodeled environmental effects. The result is consistent with the EEP at the 2 percent level. The experiment can also be viewed as setting a limit on a possible spatial variation of the fine-structure constant.

Turneaure, J. P.

Atomic clocks for astrophysical measurements

It is noted that recently developed atomic hydrogen masers have achieved stability well into the 10 to the -16th domain for averaging time intervals beyond 1000 sec and that further improvements are in prospect. These devices are highly adaptable for space use in very high precision measurements of angle through Very Long Baseline Interferometry (VLBI) and of range and range-rate through Doppler techniques. Space missions that will use these clocks for measuring the sun's gravity field distribution and for testing gravitation and relativity (a project that will include a search for pulsed low-frequency gravitational waves) are discussed. Estimates are made of system performance capability, and the accuracy capability of relativistic measurements is evaluated in terms of the results from the 1976 NASA/SAO spaceborne clock test of the Einstein Equivalence Principle.

Vessot, R. F. C.

Test of relativistic gravitation with a space-borne hydrogen maser

The results of a test of general relativity with use of a hydrogen-maser frequency standard in a spacecraft launched nearly vertically upward to 10,000 km are reported. The agreement of the observed relativistic frequency shift with prediction is at the 70 x 10 to the -6th level.

Vessot, R. F. C.

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.

Gaseous electronics

Electron-electron relaxation rates determined from time-dependent electron velocity distribution

VELOCITY DISTRIBUTION