Microprocessor-based cardiopulmonary monitor
Incorporation of microprocessors in design of complete cardiopulmonary monitoring system alloys size reduction and cuts power requirements by ninety percent.
Engineering topics
Publications and source records attributed to Mauldin, D. G..
Incorporation of microprocessors in design of complete cardiopulmonary monitoring system alloys size reduction and cuts power requirements by ninety percent.
Cardiac output was measured during preflight and postflight exercise-stress tests on the Skylab astronauts. In the postflight tests immediately following the 28-, 59-, and 84-d earth orbital missions, the astronauts exhibited an approximate 30% decrease in cardiac output coupled with an approximate 50% decrease in cardiac stroke volume during exercise. These changes were accompanied by elevated heart rates and significant increases in total systemic peripheral vascular resistance. Mean arterial pressure was unchanged. All parameters returned to normal preflight values within 30 d of the end of the orbital period. Duration of the zero-G exposure did not appear to influence either the magnitude of the hemodynamic changes or the time-course of their return to normal. These results are discussed in relation to other cardiovascular findings and possible mechanisms responsible for the observations are outlined.
Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.
An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.
The single-breath cardiac output measurement technique of Kim et al. (1966) has been modified for use in obtaining cardiac output measurements during exercise-stress tests on Apollo astronauts. The modifications involve the use of a respiratory mass spectrometer for data acquisition and a digital computer program for data analysis. The variation of the modified method for triplicate steady-state cardiac output measurements was plus or minus 1 liter/min. The combined physiological and methodological variation seen during a set of three exercise tests on a series of subjects was 1 to 2.5 liter/min. Comparison of the modified method with the direct Fick technique showed that although the single-breath values were consistently low, the scatter of data was small and the correlation between the two methods was high. Possible reasons for the low single-breath cardiac output values are discussed.
Real time contourogram for monitoring ECG waveform data, describing cardiac measurement and data display
Real time contourographic electrocardiographic display determining heart rate from CRT face on beat-by-beat basis