Search NASA⌕ Search

Engineering topics

Mavromatakis, Fotis

Publications and source records attributed to Mavromatakis, Fotis.

Reference Cell Performance and Modeling on a One-Axis Tracking Surface: Preprint

Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.

modeling↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Improved field evaluation of reference cells using spectral measurements

Output from an IMT reference solar cell mounted on a one-axis tracking surface is investigated using spectral measurements covering the 350–1650 nm range for selected days throughout the year. Comparisons are made to a Class-A pyranometer also mounted on the one-axis tracking surface. Systematic biases over the day and year are observed in the ratio of the reference cell’s measurements to reference pyranometer measurements. This systematic bias is associated with the spectral, temperature, and angle-of-incident effects that differ between the reference cell and the reference pyranometer. The comparison is done for selected clear and totally cloudy days to determine the magnitude of the effects and to characterize the influence of these effects on the reference cell measurements. A model to calculate the reference cell output based on spectral irradiance and reference cell temperature is introduced.

14 SOLAR ENERGY↗

Using Spectral Measurements to Characterize Solar Reference Cells on a Two-Axis Tracker

A study is commencing relating the spectral responsivity of reference cells in the field to changing spectral distribution during the day. Initial results indicate that measurements of the incident spectral distribution can be used to match results of reference cell measurements on a two-axis tracker with a standard deviation of ±0.25% under clear-sky conditions. Initial results are provided. As more data are obtained covering a variety of field conditions and locations, the robustness of these results will be tested. The website https://midcdmz.nrel.gov/apps/sitehome.pl?site=PVRES contains the data generated by this project.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Reducing Interanalyst Variability in Photovoltaic Degradation Rate Assessments

The economic return on investment of a commercial photovoltaic system depends greatly on its performance over the long term and, hence, its degradation rate. Many methods have been proposed for assessing system degradation rates from outdoor performance data. However, comparing reported values from one analyst and research group to another requires a common baseline of performance; consistency between methods and analysts can be a challenge. An interlaboratory study was conducted involving different volunteer analysts reporting on the same photovoltaic performance data using different methodologies. Initial variability of the reported degradation rates was so high that analysts could not come to a consensus whether a system degraded or not. More consistent values are received when written guidance is provided to each analyst. Further improvements in analyst variance was accomplished by using the free open-source software RdTools, allowing a reduction in variance between analysts by more than two orders of magnitude over the first round, where multiple analysis methods are allowed. This article highlights many pitfalls in conducting 'routine' degradation analysis, and it addresses some of the factors that must be considered when comparing degradation results reported by different analysts or methods.

14 SOLAR ENERGY↗

Removing Biases from Rotating Shadowband Radiometers

Three types of biases are examined for a Rotating Shadowband Radiometer (RSR): temperature bias, spectral bias, and deviation from a Lambertian cosine response. A step by step method is presented to illustrate how to use this information to develop a model for adjustment algorithms for a RSR. Comparisons are made with a RSR adjusted using the model and measure direct normal, diffuse, and global irradiance.

14 SOLAR ENERGY↗

Removing Biases from Rotating Shadowband Radiometers: Preprint

Three types of biases are examined for a rotating shadowband radiometer (RSR): temperature bias, spectral bias, and deviation from a Lambertian cosine response. A step-by-step method is presented to illustrate how to use this information to develop a model for adjustment algorithms for a RSR. Comparisons are made with a RSR adjusted using the model and measure direct normal, diffuse, and global irradiance.

14 SOLAR ENERGY↗

Evaluation of Photodiode-Based Pyranometers and Reference Solar Cells on a Two-Axis Tracking System

The performance of photodiode-based pyranometers and reference solar cells are examined on a two-axis tracker surface. This is the third in a series of papers examining the performance of photodiode-based pyranometers and reference solar cells on fixed and tracking surfaces. Because the instruments are oriented normally to the incident radiation, angle-of-incidence effects are minimized. By removing the angle-of-incidence effects inherent in earlier studies, the change in the sensor's clear sky responsivity can be more clearly identified. It was found that the photodiode-based pyranometers demonstrate a larger change in responsivity than the reference solar cells. Spectral measurements are recommended to verify the cause of this difference.

14 SOLAR ENERGY↗

Evaluation of Photodiode-Based Pyranometers and Reference Solar Cells on a Two-Axis Tracking System: Preprint

The performance of photodiode-based pyranometers and reference solar cells are examined on a two-axis tracker surface. This is the third in a series of papers examining the performance of photodiode-based pyranometers and reference solar cells on fixed and tracking surfaces. Because the instruments are oriented normally to the incident radiation, angle-of-incidence effects are minimized. By removing the angle-of-incidence effects found in earlier studies, the change in the sensor's responsivity during the day can be more clearly identified. It was found that the photodiode-based pyranometers demonstrate a larger change in responsivity than the reference solar cells. Spectral measurements are recommended to verify the cause of this difference.

14 SOLAR ENERGY↗

Comparison of Pyranometers and Reference Cells on Fixed and One-Axis Tracking Surfaces: Preprint

A wide variety of sensors are used to monitor the irradiance incident on solar modules to evaluate the performance of photovoltaic (PV) systems. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules, a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles of incidence, even though both instruments are based on measuring the short-circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded-base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer, which has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Use of Pyranometers to Estimate PV Module Degradation Rates in the Field

Methodology is described that uses relative measurements to estimate the degradation rates of PV modules in the field. The importance of calibration and cleaning is discussed. The number of years of field measurements needed to measure degradation rates with data from the field is cut in half using relative comparisons.