Comparative performance of modern digital mammography systems in a large breast screening program

Purpose: To compare physical measures pertaining to image quality among digital mammography systems utilized in a large breast screening program. To examine qualitatively differences in these measures and differences in clinical cancer detection rates between CR and DR among sites within that program. Methods: As part of the routine quality assurance program for screening, field measurements are made of several variables considered to correlate with the diagnostic quality of medical images including: modulation transfer function, noise equivalent quanta, d′ (an index of lesion detectability) and air kerma to allow estimation of mean glandular dose. In addition, images of the mammography accreditation phantom are evaluated. Results: It was found that overall there were marked differences between the performance measures of DR and CR mammography systems. In particular, the modulation transfer functions obtained with the DR systems were found to be higher, even for larger detector element sizes. Similarly, the noise equivalent quanta, d′, and the phantom scores were higher, while the failure rates associated with low signal-to-noise ratio and high dose were lower with DR. These results were consistent with previous findings in the authors’ program that the breast cancer detection rates at sites employing CR technology were, on average, 30.6% lower than those that used DR mammography. Conclusions: While the clinical study was not large enough to allow a statistically powered system-by-system assessment of cancer detection accuracy, the physical measures expressing spatial resolution, and signal-to-noise ratio are consistent with the published finding that sites employing CR systems had lower cancer detection rates than those using DR systems for screening mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗

Measurement of compressed breast thickness by optical stereoscopic photogrammetry

The determination of volumetric breast density (VBD) from mammograms requires accurate knowledge of the thickness of the compressed breast. In attempting to accurately determine VBD from images obtained on conventional mammography systems, the authors found that the thickness reported by a number of mammography systems in the field varied by as much as 15 mm when compressing the same breast or phantom. In order to evaluate the behavior of mammographic compression systems and to be able to predict the thickness at different locations in the breast on patients, they have developed a method for measuring the local thickness of the breast at all points of contact with the compression paddle using optical stereoscopic photogrammetry. On both flat (solid) and compressible phantoms, the measurements were accurate to better than 1 mm with a precision of 0.2 mm. In a pilot study, this method was used to measure thickness on 108 volunteers who were undergoing mammography examination. This measurement tool will allow us to characterize paddle surface deformations, deflections and calibration offsets for mammographic units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗