Advances in sapphire optical fiber sensors

We describe the development and testing of two sapphire fiber sensor designs intended for use in high temperature environments. The first is a birefringence-balanced polarimetric sapphire fiber sensor. In this sensor, two single crystal sapphire rods, acting as the birefringence sensing element, are connected to each other in such a way that the slow axis of the first rod is aligned along with the fast axis of the second rod, and the fast axis of the first rod is along the slow axis of the second rod. This sensor has been demonstrated for measurement of temperature up to 1500 C. The second is a sapphire-fiber-based intrinsic interferometric sensor. In this sensor, a length of uncoated, unclad, structural-graded multimode sapphire fiber is fusion spliced to a singlemode silica fiber to form a Fabry-Perot cavity. The reflections from the silica-to-sapphire fiber splice and the free endface of the sapphire fiber give rise to the interfering fringe output. This sensor has been demonstrated for the measurement of temperature above 1510 C, and a resolution of 0.1 C has been obtained.

Wang, Anbo↗

Sapphire-fiber-based intrinsic Fabry-Perot interferometer

A sapphire optical fiber intrinsic Fabry-Perot interferometric sensor is demonstrated. A length of multimode sapphire fiber that functions as a Fabry-Perot cavity is spliced to a silica single-mode fiber. The interferometric signals of this sensor are produced by the interference between the reflection from the silica-sapphire fiber splice and the reflection from the free end face of the sapphire fiber. This sensor has been demonstrated for temperature measurement. A resolution of 0.2 C has been obtained over a measurement range of 310 C to 976 C.

Wang, Anbo↗

Holographic matched filter for full-field in-line signal processing of optical-fiber sensor outputs

A holographic matched filter is used to measure the changes in the output of a dual-mode fiber undergoing axial strain. The hologram is formed by interfering collimated light from a single-mode reference fiber and an unstrained dual-mode sensor fiber on a small piece of holographic material. When the hologram is illuminated by the strained sensor fiber, the cross-correlation field comparing the dual-mode output and its previous state, as recorded in the hologram, is collected, focused into a pick-up fiber, and sent to a photodiode. This arrangement allows for a compact, in-line method for full-field processing of the strain-induced changes in phase and amplitude in the sensor fiber. Other uses of such fiber-based correlators are suggested.

Indebetouw, Guy↗