Applicability of the ARCON96 Code to the Radiological Consequence Analysis of Releases from the Radioassay and Non-Destructive Testing (RANT) Facility
Establish technical justification to demonstrate that the horizontal diffusion parameter (σy) and vertical diffusion parameter (σz) that are embedded in the Nuclear Regulatory Commission (NRC) Atmospheric Relative CONcentrations (ARCON96) code are representative of the meteorological conditions at LANL. Compare the ARCON96 atmospheric diffusion factor ( X /Q) to the MACCS2-calculated X /Q for the determination of radiological consequences of ground releases from the Radioassay and Non-Destructive Testing (RANT) facility on the key receptors, the colocated worker (CW) and Maximally-Effected Offsite Individual (MEOI).